A Comparison of the Detection of Hypoventilation During Deep Sedation Utilizing Nasal End Title CO@ Versus Transcutaneous CO2 Measurement Techniques

25 de junho de 2014 atualizado por: Gildasio De Oliveira, Northwestern University

The estimation of the partial pressure of carbon dioxide (PCO2) in the arterial blood is used to judge the adequacy of ventilation during spontaneous and controlled ventilation. Although the gold standard for monitoring PCO2 remains arterial blood gas sampling, this requires an invasive procedure and provides only an intermittent estimate of what is frequently a continuously changing value. The solution to this problem has been the development and validation of accurate noninvasive monitoring techniques which provide a continuous intraoperative estimate of PCO2.The most commonly used noninvasive technique to monitor PCO2 is measurement of the end tidal CO2 (PECO2) . However, sampling errors and patient -related issues such as ventilation-perfusion mismatch, patient positioning or decreases in pulmonary blood flow may influence the accuracy of PECO2 monitoring (1-3). Nasal capnography has been proved to be an accurate monitor during the post-operative period (4) but its ability to accurately detect hypoventilation associated with deep sedation has not been studied.

According to the American Society of Anesthesiologist standards for basic monitoring, continuous capnography is required for all patients undergoing general anesthesia but it is optional for MAC/sedation cases. The need for CO2 monitoring has been studied by other medical specialties that use procedural sedation, including gastroenterology (12) and emergency medicine (13, 14) and many specialties now recommend capnography as a standard monitor.

Patients receiving supplemental oxygen may experience significant persistent hypoventilation leading to progressive hypercarbia and acidosis which may go undetected for a significant time interval since the routinely monitored SpO2 may be maintained within normal range. A recent study has shown that despite the fact that end tidal CO2 is reliable in detecting apnea , increasing oxygen flow rates decrease the amplitude of measured CO2, probably via dilution, making the quantitative value less reliable as an assessment of adequacy of ventilation (15). Furthermore, during hypoventilation there is reduced alveolar ventilation and the end tidal CO2 is not a true reflection of arterial CO2.

Transcutaneous measurement of PCO2(PtcCO2) is a non-invasive method of measuring PCO2 that has been used much less frequently due to technical difficulties with earlier transcutaneous electrodes. Preliminary studies of the reliability of the current PtcCO2 electrodes (TOSCA, Linde Medical Sensors, and Basel, Switzerland) have shown good correlation of arterial and transcutaneous measurements in both adult volunteers and anesthetized subjects (5). PtcCO2 is measured with a sensor attached by a low pressure clip to an earlobe. The sensor probe heats the earlobe to 42 degrees Celsius to enhance blood flow. The current sensors have also been evaluated in anesthetized children (7, 8), anesthetized adults (9, 10) and critically ill neonates (11) and all these studies revealed a good correlation between PtCO2 and PaCO2.

Visão geral do estudo

Status

Concluído

Intervenção / Tratamento

Descrição detalhada

A group of _40 patients scheduled to undergo Hysteroscopy surgery with deep sedation will be studied. Standard monitors will be utilized. Additionally a transcutaneous CO2 electrode will be attached to the ear lobe and a BIS monitor will be applied to the forehead.

The anesthetic management will be left to the discretion of the anesthesia provider (Anesthesia resident or CRNA, under the supervision of a faculty attending anesthesiologist).All patients will receive supplemental oxygen at 3L/ minute via nasal cannula, to maintain oxygen saturation greater than 90%.

Both the end tidal CO2 (ETCO2) and transcutaneous CO2 (TcCO2) (Linde Medical Sensors, Basel , Switzerland ) will be calibrated before use, according to the manufacturer's instruction.. The anesthesia provider will be blinded to the TcCO2 monitor but will have access to the ETCO2 values. The ETCO2 and TcCO2 values will be recorded simultaneously by an independent observer.

One arterial blood samples will be collected from each subject for measurement of PaCO2 at a deep level of sedation defined by a modified Ramsey score greater or equal to 5 (1= anxious/agitated/restless; 2= cooperative/oriented/tranquil; 3= drowsy/responds to commands only; 4= brisk response to shaking/loud sound; 5= sluggish response to shaking/loud sound; 6= no response) The ETCO2 and .TcCO2 will be recorded throughout the time of obtaining the blood sample every 15 seconds and the mean value will be used for comparison. Hypoventilation will be defined as a PaCO2 level greater than 45mmHg.

Sedation score (OASS) will be recorded on admission to recovery area. Time to meet discharge criteria will be recorded.

The experimental procedures: ABG draw, ETCO2 monitor placement on the ear, 2 Ramey scale assessments.

Tipo de estudo

Intervencional

Inscrição (Real)

40

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Illinois
      • Chicago, Illinois, Estados Unidos, 60611
        • Northwestern University

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Fêmea

Descrição

Inclusion Criteria:

  • Age>18 years of age
  • Sex: Non-pregnant, Female
  • ASA PS: I, II
  • Surgery: Elective Hysteroscopy surgery
  • Consent: Obtained

Exclusion Criteria:

  • Age < 18 years old
  • Patients who refuses participation
  • History of lung disease
  • History of Obstructive sleep apnea

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Diagnóstico
  • Alocação: Não randomizado
  • Modelo Intervencional: Atribuição de grupo único
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: All participants
All participants, one arterial blood draw
One arterial blood draw

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
TcCo2 vs PACo2 Difference
Prazo: 1 hour
Evaluate the correlation between PaCO2- TcCO2 in detecting hypoventilation for patients undergoing deep sedation Absolute mean difference between TcCo2 and the PA Co2
1 hour

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Diretor de estudo: Robert McCarthy, PharmD, Northwestern University

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo

1 de junho de 2009

Conclusão Primária (Real)

1 de agosto de 2009

Conclusão do estudo (Real)

1 de agosto de 2009

Datas de inscrição no estudo

Enviado pela primeira vez

5 de agosto de 2009

Enviado pela primeira vez que atendeu aos critérios de CQ

6 de agosto de 2009

Primeira postagem (Estimativa)

7 de agosto de 2009

Atualizações de registro de estudo

Última Atualização Postada (Estimativa)

24 de julho de 2014

Última atualização enviada que atendeu aos critérios de controle de qualidade

25 de junho de 2014

Última verificação

1 de junho de 2014

Mais Informações

Termos relacionados a este estudo

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Ensaios clínicos em Arterial blood draw

3
Se inscrever