A Comparison of the Detection of Hypoventilation During Deep Sedation Utilizing Nasal End Title CO@ Versus Transcutaneous CO2 Measurement Techniques

25. juni 2014 opdateret af: Gildasio De Oliveira, Northwestern University

The estimation of the partial pressure of carbon dioxide (PCO2) in the arterial blood is used to judge the adequacy of ventilation during spontaneous and controlled ventilation. Although the gold standard for monitoring PCO2 remains arterial blood gas sampling, this requires an invasive procedure and provides only an intermittent estimate of what is frequently a continuously changing value. The solution to this problem has been the development and validation of accurate noninvasive monitoring techniques which provide a continuous intraoperative estimate of PCO2.The most commonly used noninvasive technique to monitor PCO2 is measurement of the end tidal CO2 (PECO2) . However, sampling errors and patient -related issues such as ventilation-perfusion mismatch, patient positioning or decreases in pulmonary blood flow may influence the accuracy of PECO2 monitoring (1-3). Nasal capnography has been proved to be an accurate monitor during the post-operative period (4) but its ability to accurately detect hypoventilation associated with deep sedation has not been studied.

According to the American Society of Anesthesiologist standards for basic monitoring, continuous capnography is required for all patients undergoing general anesthesia but it is optional for MAC/sedation cases. The need for CO2 monitoring has been studied by other medical specialties that use procedural sedation, including gastroenterology (12) and emergency medicine (13, 14) and many specialties now recommend capnography as a standard monitor.

Patients receiving supplemental oxygen may experience significant persistent hypoventilation leading to progressive hypercarbia and acidosis which may go undetected for a significant time interval since the routinely monitored SpO2 may be maintained within normal range. A recent study has shown that despite the fact that end tidal CO2 is reliable in detecting apnea , increasing oxygen flow rates decrease the amplitude of measured CO2, probably via dilution, making the quantitative value less reliable as an assessment of adequacy of ventilation (15). Furthermore, during hypoventilation there is reduced alveolar ventilation and the end tidal CO2 is not a true reflection of arterial CO2.

Transcutaneous measurement of PCO2(PtcCO2) is a non-invasive method of measuring PCO2 that has been used much less frequently due to technical difficulties with earlier transcutaneous electrodes. Preliminary studies of the reliability of the current PtcCO2 electrodes (TOSCA, Linde Medical Sensors, and Basel, Switzerland) have shown good correlation of arterial and transcutaneous measurements in both adult volunteers and anesthetized subjects (5). PtcCO2 is measured with a sensor attached by a low pressure clip to an earlobe. The sensor probe heats the earlobe to 42 degrees Celsius to enhance blood flow. The current sensors have also been evaluated in anesthetized children (7, 8), anesthetized adults (9, 10) and critically ill neonates (11) and all these studies revealed a good correlation between PtCO2 and PaCO2.

Studieoversigt

Status

Afsluttet

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

A group of _40 patients scheduled to undergo Hysteroscopy surgery with deep sedation will be studied. Standard monitors will be utilized. Additionally a transcutaneous CO2 electrode will be attached to the ear lobe and a BIS monitor will be applied to the forehead.

The anesthetic management will be left to the discretion of the anesthesia provider (Anesthesia resident or CRNA, under the supervision of a faculty attending anesthesiologist).All patients will receive supplemental oxygen at 3L/ minute via nasal cannula, to maintain oxygen saturation greater than 90%.

Both the end tidal CO2 (ETCO2) and transcutaneous CO2 (TcCO2) (Linde Medical Sensors, Basel , Switzerland ) will be calibrated before use, according to the manufacturer's instruction.. The anesthesia provider will be blinded to the TcCO2 monitor but will have access to the ETCO2 values. The ETCO2 and TcCO2 values will be recorded simultaneously by an independent observer.

One arterial blood samples will be collected from each subject for measurement of PaCO2 at a deep level of sedation defined by a modified Ramsey score greater or equal to 5 (1= anxious/agitated/restless; 2= cooperative/oriented/tranquil; 3= drowsy/responds to commands only; 4= brisk response to shaking/loud sound; 5= sluggish response to shaking/loud sound; 6= no response) The ETCO2 and .TcCO2 will be recorded throughout the time of obtaining the blood sample every 15 seconds and the mean value will be used for comparison. Hypoventilation will be defined as a PaCO2 level greater than 45mmHg.

Sedation score (OASS) will be recorded on admission to recovery area. Time to meet discharge criteria will be recorded.

The experimental procedures: ABG draw, ETCO2 monitor placement on the ear, 2 Ramey scale assessments.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

40

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Illinois
      • Chicago, Illinois, Forenede Stater, 60611
        • Northwestern University

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Kvinde

Beskrivelse

Inclusion Criteria:

  • Age>18 years of age
  • Sex: Non-pregnant, Female
  • ASA PS: I, II
  • Surgery: Elective Hysteroscopy surgery
  • Consent: Obtained

Exclusion Criteria:

  • Age < 18 years old
  • Patients who refuses participation
  • History of lung disease
  • History of Obstructive sleep apnea

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Diagnostisk
  • Tildeling: Ikke-randomiseret
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: All participants
All participants, one arterial blood draw
One arterial blood draw

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
TcCo2 vs PACo2 Difference
Tidsramme: 1 hour
Evaluate the correlation between PaCO2- TcCO2 in detecting hypoventilation for patients undergoing deep sedation Absolute mean difference between TcCo2 and the PA Co2
1 hour

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Studieleder: Robert McCarthy, PharmD, Northwestern University

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. juni 2009

Primær færdiggørelse (Faktiske)

1. august 2009

Studieafslutning (Faktiske)

1. august 2009

Datoer for studieregistrering

Først indsendt

5. august 2009

Først indsendt, der opfyldte QC-kriterier

6. august 2009

Først opslået (Skøn)

7. august 2009

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Skøn)

24. juli 2014

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

25. juni 2014

Sidst verificeret

1. juni 2014

Mere information

Begreber relateret til denne undersøgelse

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Kirurgi

Kliniske forsøg med Arterial blood draw

3
Abonner