Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Heart Rate Evaluation and Resuscitation Trial in Preterm Neonates (HEART)

19 de dezembro de 2018 atualizado por: Vishal Kapadia, University of Texas Southwestern Medical Center
The purpose of this study is to determine whether using electrocardiograms (ECGs) during resuscitation of preterm infants (less than 31 weeks gestation) will decrease the amount of time it takes from birth for heart rate (HR) to be above 100 beats per minute and oxygen saturations to be in the goal range, in other words to stabilize the infant. A few studies have been conducted which showed that ECGs are faster at detecting HR than pulse oximetry (PO). Sample sizes, however, have been small and only few extremely low birthweight infants have been included. It is unclear if use of ECG in these tiny preterm infants in addition to traditional techniques to determine HR will be beneficial and impact resuscitation and outcomes. The investigators propose a study where infants will be randomized to either using ECG in addition to PO ± auscultation versus PO ± auscultation only to assess HR during neonatal resuscitation. The investigators hypothesize that the group of infants randomized to ECG will be able to stabilize faster, i.e. achieve HR > 100 beats per minute and oxygen saturation in goal range faster.

Visão geral do estudo

Tipo de estudo

Intervencional

Inscrição (Real)

51

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Texas
      • Dallas, Texas, Estados Unidos, 75235
        • Parkland Hospital

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

Não mais velho que 1 hora (Filho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • Preterm infants less than <31 weeks gestation born at Parkland hospital vaginally or by C/S
  • Infant with congenital heart disease, congenital anomalies, or chromosomal abnormalities will be included unless comfort care has been agreed upon beforehand
  • Resuscitation team present to attend delivery before birth

Exclusion Criteria:

  • Any infant with prenatally agreed upon comfort care since resuscitation will not be provided
  • Any precipitous delivery since resuscitation team will not be in attendance prior to delivery

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Outro
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Comparador Ativo: Control group
Pulse oximeter and auscultation to determine heart rate during neonatal resuscitation. Pulse oximeter will be used to determine oxygen saturation.
Control
Experimental: Electrocardiogram group
Electrocardiogram to determine heart rate during neonatal resuscitation. Pulse oximeter will still be used per Neonatal Resuscitation Program guidelines for oxygen saturation.
Experimental

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Time to Infant Stabilization
Prazo: During delivery room resuscitation, up to 1 hour
Amount of time it takes from birth for heart rate to be above 100 beats per minute and oxygen saturation to be in the goal range (per Neonatal Resuscitation Program guidelines)
During delivery room resuscitation, up to 1 hour

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Time to heart rate >100 beats per minute
Prazo: During delivery room resuscitation, up to 1 hour
Time in delivery room
During delivery room resuscitation, up to 1 hour
Time to goal oxygen saturation
Prazo: During delivery room resuscitation, up to 1 hour
Time in delivery room
During delivery room resuscitation, up to 1 hour
Time of positive pressure ventilation
Prazo: During delivery room resuscitation, up to 1 hour
Total time positive pressure received in delivery room
During delivery room resuscitation, up to 1 hour
Incidence of positive pressure ventilation
Prazo: During delivery room resuscitation, up to 1 hour
Positive pressure ventilation applied in delivery room
During delivery room resuscitation, up to 1 hour
Incidence of CPR
Prazo: During delivery room resuscitation, up to 1 hour
CRP applied in delivery room
During delivery room resuscitation, up to 1 hour
Incidence of intubation
Prazo: During delivery room resuscitation, up to 1 hour
Intubation in delivery room
During delivery room resuscitation, up to 1 hour
Maximum FiO2 applied
Prazo: During delivery room resuscitation, up to 1 hour
FiO2 applied in delivery room
During delivery room resuscitation, up to 1 hour
Maximum peak inspiratory pressure
Prazo: During delivery room resuscitation, up to 1 hour
Maximum peak inspiratory pressure in delivery room
During delivery room resuscitation, up to 1 hour
Incidence of hypothermia
Prazo: Until hospital discharge, up to 6 months
Hypothermia on admission to NICU
Until hospital discharge, up to 6 months
Incidence of need for surfactant
Prazo: Until hospital discharge, up to 6 months
Surfactant given while in NICU
Until hospital discharge, up to 6 months
Incidence of bronchopulmonary dysplasia
Prazo: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of respiratory distress syndrome
Prazo: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of pneumothorax
Prazo: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of intraventricular hemorrhage
Prazo: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of necrotizing enterocolitis
Prazo: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of sepsis
Prazo: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of symptomatic PDA
Prazo: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of appropriate vs inappropriate use of positive pressure ventilation
Prazo: During delivery room resuscitation, up to 1 hour
Use in delivery room
During delivery room resuscitation, up to 1 hour
Incidence of equipment failure of pulse oximeter and electrocardiogram
Prazo: During delivery room resuscitation, up to 1 hour
Failure in delivery room
During delivery room resuscitation, up to 1 hour

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

13 de junho de 2017

Conclusão Primária (Real)

23 de março de 2018

Conclusão do estudo (Real)

23 de março de 2018

Datas de inscrição no estudo

Enviado pela primeira vez

22 de abril de 2017

Enviado pela primeira vez que atendeu aos critérios de CQ

25 de abril de 2017

Primeira postagem (Real)

28 de abril de 2017

Atualizações de registro de estudo

Última Atualização Postada (Real)

21 de dezembro de 2018

Última atualização enviada que atendeu aos critérios de controle de qualidade

19 de dezembro de 2018

Última verificação

1 de dezembro de 2018

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 092016-048

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

Não

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Ensaios clínicos em Reanimação Neonatal

Ensaios clínicos em Pulse oximeter and auscultation group

Se inscrever