Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Раннее технико-экономическое обоснование клапана Autus

15 октября 2026 г. обновлено: Edwards Lifesciences

Предварительное технико-экономическое обоснование клапана Autus с регулируемым размером для хирургической замены клапана легочной артерии

Prospective, single-arm, multi-center study to evaluate safety and effectiveness of the Autus Size-Adjustable Valve in pediatric patients aged 18 months to 16 years requiring surgical pulmonary valve replacement. The Autus Valve may be expanded pre-implant to match the subject's body size. Subjects will be evaluated prior to the Autus Valve implant procedure, immediately post-implant, at hospital discharge, 30 days, 6 months, and annually through 10 years.

The Autus Valve may be expanded post-implant via transcatheter balloon dilation to accommodate growth of the subject. In subjects who undergo a post-implant valve expansion, follow-up will continue for a minimum of 1 year after the post-implant valve expansion procedure.

Обзор исследования

Статус

Активный, не рекрутирующий

Вмешательство/лечение

Тип исследования

Интервенционный

Регистрация (Действительный)

62

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

    • California
      • Los Angeles, California, Соединенные Штаты, 90027
        • Children's Hospital Los Angeles
    • Colorado
      • Aurora, Colorado, Соединенные Штаты, 80045
        • Children's Hospital Colorado
    • Georgia
      • Atlanta, Georgia, Соединенные Штаты, 30322
        • Children's Healthcare of Atlanta
    • Illinois
      • Chicago, Illinois, Соединенные Штаты, 60611
        • Ann and Robert H. Lurie Children's Hospital of Chicago
    • Massachusetts
      • Boston, Massachusetts, Соединенные Штаты, 02115
        • Boston Children's Hospital
    • Michigan
      • Ann Arbor, Michigan, Соединенные Штаты, 48109
        • University of Michigan - Mott Children's Hospital
    • New York
      • New York, New York, Соединенные Штаты, 10032
        • Columbia University Irving Medical Center/New York Presbyterian Morgan Stanley Children's Hospital
    • North Carolina
      • Durham, North Carolina, Соединенные Штаты, 27703
        • Duke University
    • Ohio
      • Columbus, Ohio, Соединенные Штаты, 43205
        • Nationwide Children's Hospital
    • Pennsylvania
      • Philadelphia, Pennsylvania, Соединенные Штаты, 19104
        • Children's Hospital of Philadelphia
    • Utah
      • Salt Lake City, Utah, Соединенные Штаты, 84113
        • University of Utah - Intermountain Primary Children's Hospital
    • Washington
      • Seattle, Washington, Соединенные Штаты, 98105
        • Seattle Children's Hospital

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

От 1 год до 16 лет (Ребенок)

Принимает здоровых добровольцев

Нет

Полы, имеющие право на обучение

Все

Описание

Inclusion Criteria:

Candidates must meet all of the following inclusion criteria to be considered for enrollment in this study.

  1. Age 18 months to 16 years.

  2. Male or female.

  3. Subject has a native or repaired right ventricular outflow tract.

  4. Subject has been recommended for surgical pulmonary valve replacement by treating clinical team (cardiologist and cardiac surgeon).

  5. Subject has at least one of the following echocardiographic findings:

    1. Severe pulmonary stenosis (defined as RV to PA peak instantaneous gradient ≥60 mmHg);
    2. Moderate or greater pulmonary regurgitation;
    3. Moderate or greater pulmonary stenosis plus moderate or greater pulmonary regurgitation.
  6. Subject's body size is suitable for implantation of a study device ranging from 12.7 to 22 mm (internal diameter).

  7. Subject and parent/legal representative, where appropriate, are willing to provide informed written consent.

  8. Subject and parent/legal representative, where appropriate, and treating physician agree that the subject will return for, and comply with, all required study assessments and follow-up visits.

Exclusion Criteria:

Candidates will be excluded from the study if any of the following conditions are met:

  1. Subject requires valve replacement in a non-pulmonary position.
  2. Subject has a prosthetic valve at other valve position or will need a prosthetic valve at other valve position (i.e., anticipate additional valve replacements needed within 3 years).
  3. Subject has pulmonary arterial hypertension (defined as mean PA pressure ≥25 mmHg).
  4. Subject has pulmonary atresia and major aortopulmonary collaterals.
  5. Subject has significant peripheral pulmonary artery stenosis.
  6. Subject has an active infection requiring current systemic antibiotic therapy (if temporary illness, subject may be a candidate 4 weeks after discontinuation of antibiotics).
  7. Subject has active endocarditis or a history of infective endocarditis.
  8. Subject has renal insufficiency as determined by a serum creatinine (S-Cr) level ≥2.5 mg/dL within 60 days prior to the Screening Visit, or has end-stage renal disease.
  9. Subject has leukopenia (defined as a white blood cell (WBC) count <3.5 x 103/µL)
  10. Subject has acute or chronic anemia (defined as hemoglobin (Hgb) <10.0 g/dl or 6 mmol/L).
  11. Subject has thrombocytopenia (defined as platelet count <50 x 103/µL.
  12. Subject has a known hypersensitivity to anticoagulants and antiplatelet drugs.
  13. Subject has a known autoimmune disease or receives immunosuppressant and/or immunostimulant drugs that the Investigator or Eligibility Screening Committee (ESC) believes may negatively affect study outcomes.
  14. Subject needs emergency cardiac or vascular surgery or intervention.
  15. Positive pregnancy test prior to valve implant procedure in female subjects who have had their first menses.
  16. Subject has, in the opinion of the Investigator, a life expectancy of less than 5 years.
  17. Subject or parent/legal representative refuses blood transfusions.
  18. Subject has medical, social or psychosocial factors that, in the opinion of the Investigator or ESC, could impact safety or compliance with study procedures.
  19. Subject is participating in an investigational study of a new drug, biologic or device at the time of study screening.

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Уход
  • Распределение: Н/Д
  • Интервенционная модель: Одногрупповое задание
  • Маскировка: Нет (открытая этикетка)

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: Autus Valve Arm

Pulmonary Valve Replacement Surgery with the Autus Valve

Pulmonary valve replacement surgery with the Autus Valve

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Valve Implantation Primary Safety Endpoint
Временное ограничение: 30 Days post-valve implantation

Composite Endpoint: Freedom from a device-related complication through 30 days post-valve implantation as adjudicated by an independent Clinical Events Committee (CEC), including:

  • Death;
  • Valve thrombosis requiring intervention;
  • Symptomatic thromboembolism.
30 Days post-valve implantation
Valve Implantation Primary Effectiveness Endpoint
Временное ограничение: 6 Months post-valve implantation

Acceptable hemodynamic performance at 6 months post-valve implantation, as assessed by the Echocardiography Core Laboratory or Clinical Events Committee, defined as:

  • A mean RVOT gradient less than or equal to 40 mmHg and
  • Less than moderate pulmonary regurgitation by transthoracic echo and
  • No Autus Valve reintervention except for valve expansion to address prosthesis-patient mismatch.
6 Months post-valve implantation

Другие показатели результатов

Мера результата
Мера Описание
Временное ограничение
Other Safety Outcome - Composite
Временное ограничение: 6 months and annually through a minimum of 10 years and up to 11 years post-valve implantation

The following other safety outcome will be evaluated at 6 months, and annually through 10 years post-valve implantation by an independent Clinical Events Committee. The composite outcome includes device-related:

  • Death;
  • Valve thrombosis requiring intervention;
  • Symptomatic thromboembolism.
6 months and annually through a minimum of 10 years and up to 11 years post-valve implantation
Other Safety Outcome - Mortality
Временное ограничение: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation

The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year.

• Mortality, including: all cause, cardiac-related, procedure-related and device-related

30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
Other Safety Outcome - Valve Thrombosis
Временное ограничение: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation

The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year.

• Valve thrombosis

30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
Other Safety Outcome - Thromboembolism
Временное ограничение: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation

The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year.

• Thromboembolism

30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
Other Safety Outcome - Cardiac or Valve Intervention
Временное ограничение: 30 days, 6 months, and annually through a minimum of 510 years and up to 11 years post-valve implantation

The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year.

• Other cardiac or valve intervention (surgical or transcatheter)

30 days, 6 months, and annually through a minimum of 510 years and up to 11 years post-valve implantation
Other Safety Outcome - Major Hemorrhage
Временное ограничение: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation

The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year.

• Major hemorrhage

30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
Other Safety Outcome - Endocarditis
Временное ограничение: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation

The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year.

• Endocarditis

30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
Other Safety Outcome - Hemolysis
Временное ограничение: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation

The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year.

• Hemolysis

30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
Other Safety Outcome - Device Explantation
Временное ограничение: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation

The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year.

• Device explantation

30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
Other Safety Outcome - Adverse Events (AE)
Временное ограничение: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation

The following measure will be reported at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year.

• Adverse events

30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
Other Safety Outcome - Valve/Stent Fracture
Временное ограничение: pre-discharge, 12 months, and annually through a minimum of 5 years and up to 6 years post-valve implantation. Subjects that undergo post-implant valve expansion will be evaluated pre-discharge and at 12 months post-valve expansion.

An independent Medical Reviewer will review post-implant chest x-rays to assess for valve/stent fracture. Chest x-rays will be performed at the following timepoints: post-valve implantation at hospital discharge, and annually through 5 years post-valve implantation. If a post-implant valve expansion procedure is performed, chest x-rays will be performed at hospital discharge and 12 months post-procedure.

pre-discharge, 12 months, and annually through a minimum of 5 years and up to 6 years post-valve implantation. Subjects that undergo post-implant valve expansion will be evaluated pre-discharge and at 12 months post-valve expansion.
Other Effectiveness Outcome - Valve Implant Acute Procedural Success
Временное ограничение: Immediately Post-Valve Implant Procedure

To meet the definition of success, all the parameters listed below must be achieved, as assessed by Sites using direct pressure measurements and/or transesophageal echo (TEE):

  • RV to PA peak systolic pressure gradient <40 mmHg (direct pressure measurement);
  • None or trivial pulmonary regurgitation (assessed via TEE);
  • No paravalvular leak (assessed via TEE).
Immediately Post-Valve Implant Procedure
Other Effectiveness Outcome - Pulmonary Regurgitation Grade
Временное ограничение: Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.

Pulmonary regurgitation grade categorized as none, trivial, mild, moderate, severe as evaluated by the Echo Core Laboratory.

Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
Other Effectiveness Outcome - Pulmonary Stenosis Grade
Временное ограничение: Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.

Pulmonary stenosis grade categorized as none/trivial, mild, moderate, severe, as evaluated by the Echo Core Laboratory.

Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
Other Effectiveness Outcome - Right Ventricular Measures
Временное ограничение: Baseline, 30 days, 6 months, and annually through 5 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.

Right ventricular (RV) measures, including RV dimension and strain will be evaluated by the Echo Core Laboratory.

Baseline, 30 days, 6 months, and annually through 5 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
Other Effectiveness Outcome - Left Ventricular Measures
Временное ограничение: Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.

Left ventricular (LV) measures, including LV ejection fraction and strain will be evaluated by the Echo Core Laboratory.

Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
Other Effectiveness Outcome - Modified Ross Functional Classification
Временное ограничение: Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.

Modified Ross Functional Class as assessed by the Site Investigators

Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
Other Effectiveness Outcome - PedsQL - Cardiac Module
Временное ограничение: Baseline, 6 months and annually through 10 years post-valve implantation. Subjects that undergo post-implant valve expansion will be evaluated pre-valve expansion, and at 6 and 12 months post-valve expansion.

The Pediatric Qualify of Life Inventory (PedsQL) Cardiac Module will be administered by Site Personnel.

Baseline, 6 months and annually through 10 years post-valve implantation. Subjects that undergo post-implant valve expansion will be evaluated pre-valve expansion, and at 6 and 12 months post-valve expansion.
Other Post-Implant Valve Expansion Safety Outcome - Composite
Временное ограничение: 30 days after each post-implant valve expansion procedure

Composite Endpoint: Freedom from device-related complication through 30 days post-valve expansion as adjudicated by an independent CEC:

  • Death;
  • Extracorporeal membrane oxygenation (ECMO) support;
  • Unplanned intervention (surgical or transcatheter);
  • Major hemorrhage
30 days after each post-implant valve expansion procedure
Other Post-Implant Valve Expansion Effectiveness Outcome - Acute Procedural Success
Временное ограничение: Immediately after each post-implant valve expansion procedure

To meet the definition of success, at least one of the parameters listed below must be achieved after each post-implant valve expansion is performed, assessed during the same catheterization procedure:

  • RV to aortic systolic pressure ratio: ≤0.5.
  • Peak-to-peak RV to PA systolic pressure gradient: ≤15 mmHg;
  • Peak-to-peak RV to PA systolic pressure gradient: ≥50% reduction (pre vs post valve expansion).
Immediately after each post-implant valve expansion procedure
Other Post-Implant Valve Expansion Effectiveness Outcome - Hemodynamic Performance
Временное ограничение: 6 months after each post-implant valve expansion procedure

Clinically acceptable hemodynamic performance at 6 months post-valve expansion procedure, as assessed by the Echo Core Laboratory via TTE, defined as:

  • Less than moderate pulmonary regurgitation (PR) by Doppler echocardiography;
  • Transvalvular gradient (assessed by CW Doppler) at 6-months is lower than the pre-expansion gradient.
6 months after each post-implant valve expansion procedure

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Публикации и полезные ссылки

Лицо, ответственное за внесение сведений об исследовании, добровольно предоставляет эти публикации. Это может быть что угодно, связанное с исследованием.

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

5 февраля 2024 г.

Первичное завершение (Действительный)

24 августа 2026 г.

Завершение исследования (Оцененный)

5 февраля 2036 г.

Даты регистрации исследования

Первый отправленный

23 июля 2021 г.

Впервые представлено, что соответствует критериям контроля качества

12 августа 2021 г.

Первый опубликованный (Действительный)

16 августа 2021 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

20 октября 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

15 октября 2026 г.

Последняя проверка

1 октября 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕТ

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Да

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться