Autus Valve Early Feasibility Study
Autus størrelsesjusterbar ventil til kirurgisk lungeklapudskiftning tidlig gennemførlighedsundersøgelse
Prospective, single-arm, multi-center study to evaluate safety and effectiveness of the Autus Size-Adjustable Valve in pediatric patients aged 18 months to 16 years requiring surgical pulmonary valve replacement. The Autus Valve may be expanded pre-implant to match the subject's body size. Subjects will be evaluated prior to the Autus Valve implant procedure, immediately post-implant, at hospital discharge, 30 days, 6 months, and annually through 10 years.
The Autus Valve may be expanded post-implant via transcatheter balloon dilation to accommodate growth of the subject. In subjects who undergo a post-implant valve expansion, follow-up will continue for a minimum of 1 year after the post-implant valve expansion procedure.
Studieoversigt
Status
Betingelser
Intervention / Behandling
Undersøgelsestype
Tilmelding (Faktiske)
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
California
-
Los Angeles, California, Forenede Stater, 90027
- Children's Hospital Los Angeles
-
-
Colorado
-
Aurora, Colorado, Forenede Stater, 80045
- Children's Hospital Colorado
-
-
Georgia
-
Atlanta, Georgia, Forenede Stater, 30322
- Children's Healthcare of Atlanta
-
-
Illinois
-
Chicago, Illinois, Forenede Stater, 60611
- Ann and Robert H. Lurie Children's Hospital of Chicago
-
-
Massachusetts
-
Boston, Massachusetts, Forenede Stater, 02115
- Boston Children's Hospital
-
-
Michigan
-
Ann Arbor, Michigan, Forenede Stater, 48109
- University of Michigan - Mott Children's Hospital
-
-
New York
-
New York, New York, Forenede Stater, 10032
- Columbia University Irving Medical Center/New York Presbyterian Morgan Stanley Children's Hospital
-
-
North Carolina
-
Durham, North Carolina, Forenede Stater, 27703
- Duke University
-
-
Ohio
-
Columbus, Ohio, Forenede Stater, 43205
- Nationwide Children's Hospital
-
-
Pennsylvania
-
Philadelphia, Pennsylvania, Forenede Stater, 19104
- Children's Hospital of Philadelphia
-
-
Utah
-
Salt Lake City, Utah, Forenede Stater, 84113
- University of Utah - Intermountain Primary Children's Hospital
-
-
Washington
-
Seattle, Washington, Forenede Stater, 98105
- Seattle Children's Hospital
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
Candidates must meet all of the following inclusion criteria to be considered for enrollment in this study.
-
Age 18 months to 16 years.
-
Male or female.
-
Subject has a native or repaired right ventricular outflow tract.
-
Subject has been recommended for surgical pulmonary valve replacement by treating clinical team (cardiologist and cardiac surgeon).
-
Subject has at least one of the following echocardiographic findings:
- Severe pulmonary stenosis (defined as RV to PA peak instantaneous gradient ≥60 mmHg);
- Moderate or greater pulmonary regurgitation;
- Moderate or greater pulmonary stenosis plus moderate or greater pulmonary regurgitation.
-
Subject's body size is suitable for implantation of a study device ranging from 12.7 to 22 mm (internal diameter).
-
Subject and parent/legal representative, where appropriate, are willing to provide informed written consent.
-
Subject and parent/legal representative, where appropriate, and treating physician agree that the subject will return for, and comply with, all required study assessments and follow-up visits.
Exclusion Criteria:
Candidates will be excluded from the study if any of the following conditions are met:
- Subject requires valve replacement in a non-pulmonary position.
- Subject has a prosthetic valve at other valve position or will need a prosthetic valve at other valve position (i.e., anticipate additional valve replacements needed within 3 years).
- Subject has pulmonary arterial hypertension (defined as mean PA pressure ≥25 mmHg).
- Subject has pulmonary atresia and major aortopulmonary collaterals.
- Subject has significant peripheral pulmonary artery stenosis.
- Subject has an active infection requiring current systemic antibiotic therapy (if temporary illness, subject may be a candidate 4 weeks after discontinuation of antibiotics).
- Subject has active endocarditis or a history of infective endocarditis.
- Subject has renal insufficiency as determined by a serum creatinine (S-Cr) level ≥2.5 mg/dL within 60 days prior to the Screening Visit, or has end-stage renal disease.
- Subject has leukopenia (defined as a white blood cell (WBC) count <3.5 x 103/µL)
- Subject has acute or chronic anemia (defined as hemoglobin (Hgb) <10.0 g/dl or 6 mmol/L).
- Subject has thrombocytopenia (defined as platelet count <50 x 103/µL.
- Subject has a known hypersensitivity to anticoagulants and antiplatelet drugs.
- Subject has a known autoimmune disease or receives immunosuppressant and/or immunostimulant drugs that the Investigator or Eligibility Screening Committee (ESC) believes may negatively affect study outcomes.
- Subject needs emergency cardiac or vascular surgery or intervention.
- Positive pregnancy test prior to valve implant procedure in female subjects who have had their first menses.
- Subject has, in the opinion of the Investigator, a life expectancy of less than 5 years.
- Subject or parent/legal representative refuses blood transfusions.
- Subject has medical, social or psychosocial factors that, in the opinion of the Investigator or ESC, could impact safety or compliance with study procedures.
- Subject is participating in an investigational study of a new drug, biologic or device at the time of study screening.
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: N/A
- Interventionel model: Enkelt gruppeopgave
- Maskning: Ingen (Åben etiket)
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Eksperimentel: Autus Valve Arm
Pulmonary Valve Replacement Surgery with the Autus Valve |
Pulmonary valve replacement surgery with the Autus Valve |
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Valve Implantation Primary Safety Endpoint
Tidsramme: 30 Days post-valve implantation
|
Composite Endpoint: Freedom from a device-related complication through 30 days post-valve implantation as adjudicated by an independent Clinical Events Committee (CEC), including:
|
30 Days post-valve implantation
|
|
Valve Implantation Primary Effectiveness Endpoint
Tidsramme: 6 Months post-valve implantation
|
Acceptable hemodynamic performance at 6 months post-valve implantation, as assessed by the Echocardiography Core Laboratory or Clinical Events Committee, defined as:
|
6 Months post-valve implantation
|
Andre resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Other Safety Outcome - Composite
Tidsramme: 6 months and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
The following other safety outcome will be evaluated at 6 months, and annually through 10 years post-valve implantation by an independent Clinical Events Committee. The composite outcome includes device-related:
|
6 months and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
|
Other Safety Outcome - Mortality
Tidsramme: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year. • Mortality, including: all cause, cardiac-related, procedure-related and device-related |
30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
|
Other Safety Outcome - Valve Thrombosis
Tidsramme: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year. • Valve thrombosis |
30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
|
Other Safety Outcome - Thromboembolism
Tidsramme: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year. • Thromboembolism |
30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
|
Other Safety Outcome - Cardiac or Valve Intervention
Tidsramme: 30 days, 6 months, and annually through a minimum of 510 years and up to 11 years post-valve implantation
|
The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year. • Other cardiac or valve intervention (surgical or transcatheter) |
30 days, 6 months, and annually through a minimum of 510 years and up to 11 years post-valve implantation
|
|
Other Safety Outcome - Major Hemorrhage
Tidsramme: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year. • Major hemorrhage |
30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
|
Other Safety Outcome - Endocarditis
Tidsramme: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year. • Endocarditis |
30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
|
Other Safety Outcome - Hemolysis
Tidsramme: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year. • Hemolysis |
30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
|
Other Safety Outcome - Device Explantation
Tidsramme: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
The following measure will be evaluated by an independent Clinical Events Committee at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year. • Device explantation |
30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
|
Other Safety Outcome - Adverse Events (AE)
Tidsramme: 30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
The following measure will be reported at 30 days, 6 months, and annually through 10 years post-valve implantation. Subjects that undergo valve expansion in year 10 after device implantation will be followed for an additional year. • Adverse events |
30 days, 6 months, and annually through a minimum of 10 years and up to 11 years post-valve implantation
|
|
Other Safety Outcome - Valve/Stent Fracture
Tidsramme: pre-discharge, 12 months, and annually through a minimum of 5 years and up to 6 years post-valve implantation. Subjects that undergo post-implant valve expansion will be evaluated pre-discharge and at 12 months post-valve expansion.
|
An independent Medical Reviewer will review post-implant chest x-rays to assess for valve/stent fracture. Chest x-rays will be performed at the following timepoints: post-valve implantation at hospital discharge, and annually through 5 years post-valve implantation. If a post-implant valve expansion procedure is performed, chest x-rays will be performed at hospital discharge and 12 months post-procedure. |
pre-discharge, 12 months, and annually through a minimum of 5 years and up to 6 years post-valve implantation. Subjects that undergo post-implant valve expansion will be evaluated pre-discharge and at 12 months post-valve expansion.
|
|
Other Effectiveness Outcome - Valve Implant Acute Procedural Success
Tidsramme: Immediately Post-Valve Implant Procedure
|
To meet the definition of success, all the parameters listed below must be achieved, as assessed by Sites using direct pressure measurements and/or transesophageal echo (TEE):
|
Immediately Post-Valve Implant Procedure
|
|
Other Effectiveness Outcome - Pulmonary Regurgitation Grade
Tidsramme: Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
|
Pulmonary regurgitation grade categorized as none, trivial, mild, moderate, severe as evaluated by the Echo Core Laboratory. |
Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
|
|
Other Effectiveness Outcome - Pulmonary Stenosis Grade
Tidsramme: Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
|
Pulmonary stenosis grade categorized as none/trivial, mild, moderate, severe, as evaluated by the Echo Core Laboratory. |
Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
|
|
Other Effectiveness Outcome - Right Ventricular Measures
Tidsramme: Baseline, 30 days, 6 months, and annually through 5 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
|
Right ventricular (RV) measures, including RV dimension and strain will be evaluated by the Echo Core Laboratory. |
Baseline, 30 days, 6 months, and annually through 5 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
|
|
Other Effectiveness Outcome - Left Ventricular Measures
Tidsramme: Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
|
Left ventricular (LV) measures, including LV ejection fraction and strain will be evaluated by the Echo Core Laboratory. |
Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
|
|
Other Effectiveness Outcome - Modified Ross Functional Classification
Tidsramme: Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
|
Modified Ross Functional Class as assessed by the Site Investigators |
Baseline, 30 days, 6 months, and annually through 10 years post-valve implant and 30 days, 6 months, and 12 months post-valve expansion.
|
|
Other Effectiveness Outcome - PedsQL - Cardiac Module
Tidsramme: Baseline, 6 months and annually through 10 years post-valve implantation. Subjects that undergo post-implant valve expansion will be evaluated pre-valve expansion, and at 6 and 12 months post-valve expansion.
|
The Pediatric Qualify of Life Inventory (PedsQL) Cardiac Module will be administered by Site Personnel. |
Baseline, 6 months and annually through 10 years post-valve implantation. Subjects that undergo post-implant valve expansion will be evaluated pre-valve expansion, and at 6 and 12 months post-valve expansion.
|
|
Other Post-Implant Valve Expansion Safety Outcome - Composite
Tidsramme: 30 days after each post-implant valve expansion procedure
|
Composite Endpoint: Freedom from device-related complication through 30 days post-valve expansion as adjudicated by an independent CEC:
|
30 days after each post-implant valve expansion procedure
|
|
Other Post-Implant Valve Expansion Effectiveness Outcome - Acute Procedural Success
Tidsramme: Immediately after each post-implant valve expansion procedure
|
To meet the definition of success, at least one of the parameters listed below must be achieved after each post-implant valve expansion is performed, assessed during the same catheterization procedure:
|
Immediately after each post-implant valve expansion procedure
|
|
Other Post-Implant Valve Expansion Effectiveness Outcome - Hemodynamic Performance
Tidsramme: 6 months after each post-implant valve expansion procedure
|
Clinically acceptable hemodynamic performance at 6 months post-valve expansion procedure, as assessed by the Echo Core Laboratory via TTE, defined as:
|
6 months after each post-implant valve expansion procedure
|
Samarbejdspartnere og efterforskere
Sponsor
Publikationer og nyttige links
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Faktiske)
Studieafslutning (Anslået)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- AUT-CP-001
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .