Does OCT Imaging Allow us to See Blood Vessel Development in and Around Deposits of Fat and Calcium Inside Blood Vessels
Coronary Optical Coherence Tomography Correlation and Strain Mapping to Investigate Human Atherosclerosis: a Feasibility Study
Cardiovascular disease is the leading cause of illness and death in the world. The disease involves narrowing of blood vessels due to deposits of fat which can become coated in calcium. It is treated by percutaneous coronary intervention in which a balloon is passed down the blood vessel to remove the obstruction and where appropriate a stent is placed in the blood vessel to scaffold it.
Early stage research suggests that the growth of small blood vessels in and around the deposits of fat and calcium leads to the growth of the deposit and may contribute to plaque rupture into the vessel leading to clot formation the process which leads to heart attacks. Drugs which prevent the development of these small blood vessel restrict the development of the deposit, and those that encourage the development of these small blood vessel also increase the development of the deposit. Researchers would like to find out more about the system of blood vessels around deposits of fat and calcium in the larger blood vessels. This involves looking just beneath the surface of the blood vessel wall, and requires a detailed and accurate image. Researchers on this project would like to find out if optical coherence tomography (OCT) is a suitable technique for imaging in this way.
OCT works like an ultrasound, but using light instead of sound waves. The additional imaging will prolong the clinical procedure by 10-15 minutes.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Cardiovascular disease is the leading cause of illness and death in the world. Central to the process of this disease is the narrowing of blood vessels due to deposits of fatty residue which can become coated in calcium. Significant narrowing of the blood vessels is treated by percutaneous coronary intervention in which a balloon is inflated and passed down the blood vessel to remove the obstruction and where appropriate a stent is placed in the blood vessel to scaffold it.
Potential participants are those who have been scheduled for a percutaneous coronary intervention, are stable, and have a diagnosis of angina pectoris, unstable angina or acute coronary syndrome. These patients will be identified and screened by their healthcare team. Potential participants will be given study information by their healthcare team, or identified to the research team who will provide study information. The initial approach may be in clinic, in hospital, or by post.
Participants will be asked to give written informed consent to participate in the study. At the clinical pre-procedure visit consent is sought, exclusion and inclusion criteria checked.
Procedure: On the day of the patients procedure they will receive standard clinical care comprising angiography (imaging of the blood vessel), angioplasty (removal of fatty deposits with a balloon) and stenting. Before and after the procedure the patient will receive medication and after care as per standard clinical care. Those patients who are clinically indicated for stenting will undergo OCT imaging prior to the angioplasty and stenting.
The researchers need to allow flexibility in the process of acquiring the OCT images, so they can optimize the quality of the image. Therefore, the speed of pullback (removal of the catheter) and choice of blood clearing agents will not be pre-specified. Serial images of the same part of the vessel may be taken.
As part of the clinical angioplasty procedure the patient will have a coronary guidewire passed down the artery usually from the groin to the heart which is used to position balloons and stents. OCT passes over the wire in the same way. From the patients perspective the procedure may take a small amount of additional time - maximum 10-15 minutes. We would like to be able to pass a second wire down the same coronary artery called a 'buddy wire' which is sometimes required in coronary procedures. This would be used to inflate a balloon at low pressure near the area of interest in the heart in order either to exclude blood or to oppose the OCT catheter to the vessel wall if required.
If a patient returns for subsequent percutaneous coronary intervention they will be invited to participate again.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Leicestershire
-
Leicester, Leicestershire, United Kingdom, LE3 9QP
- NIHR Cardiovascular BRU
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patients scheduled for elective percutaneous coronary intervention or coronary angiography with a view to coronary intervention on routine clinical criteria with diagnosis of angina pectoris, unstable angina or acute coronary syndrome with angiographically significant stenosis(es) (>70%) of one or more native coronary arteries.
Exclusion Criteria:
- Primary angioplasty for S T -elevation myocardial infarction. Clinically unstable patients.
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Optical coherence tomography
As part of the clinical angioplasty procedure the patient will have a coronary guidewire passed down the artery usually from the groin to the heart which is used to position balloons and stents.
OCT passes over the wire in the same way.
From the patients perspective the procedure may take a small amount of additional time - maximum 10-15 minutes.
We would like to be able to pass a second wire down the same coronary artery called a 'buddy wire' which is sometimes required in coronary procedures.
This would be used to inflate a balloon at low pressure near the area of interest in the heart in order either to exclude blood or to oppose the OCT catheter to the vessel wall if required.
|
As part of the clinical angioplasty procedure the patient will have a coronary guidewire passed down the artery usually from the groin to the heart which is used to position balloons and stents.
OCT passes over the wire in the same way.
From the patients perspective the procedure may take a small amount of additional time - maximum 10-15 minutes.
We would like to be able to pass a second wire down the same coronary artery called a 'buddy wire' which is sometimes required in coronary procedures.
This would be used to inflate a balloon at low pressure near the area of interest in the heart in order either to exclude blood or to oppose the OCT catheter to the vessel wall if required.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Markers of high risk coronary diseases
Time Frame: through study completion, an average of 1 year (Aprox March 2018)
|
Novel OCT features as potential markers of high risk coronary diseases
|
through study completion, an average of 1 year (Aprox March 2018)
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: David Adlam, BA,BM,BCH,DPhil,MRCP, NIHR Leicester Cardiovascular BRU
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 0255
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Cardiovascular Disease
-
NCT02729389CompletedCardiovascular Disease | Psychosocial Influence on Cardiovascular Disease
-
NCT07187947RecruitingCardiovascular Disease (CVD) | Gender Incongruence | Cardiovascular (CV) Risk | Cardiovascular Health Status | Cardiovascular Disease Prevention | Cardiovascular Disease Acute | Cardiovascular Disease Risk Factor
-
NCT02122575CompletedCardiovascular Disease | Inflammatory Disease
-
NCT07401550RecruitingCoronary Artery Disease (CAD) | Cardiovascular Diseases (CVD) | Cardiovascular Disease Prevention | Cardiovascular Disease Risk Factor
-
NCT07497932RecruitingCardiovascular Disease | Cardiovascular Surgery
-
NCT07521436Recruiting
-
NCT07293260Recruiting
-
NCT06740448Not yet recruitingCardiovascular Disease
-
NCT04310917Recruiting
Clinical Trials on Optical coherence tomography
-
NCT00556309Completed
-
NCT02326909CompletedTransitional Cell Carcinoma of Urinary Tract
-
NCT05739539CompletedTractional Retinal Detachment | Diabetic Vitreous Hemorrhage
-
NCT04773561RecruitingRetinal Vascular | Twin Pregnancy, Antepartum Condition or Complication | Choroidal Effusion
-
NCT04731415Not yet recruitingRetinal Vascular
-
NCT03030755RecruitingRefractive Errors | Keratoconus | Cornea; Ectasia
-
NCT04794634CompletedAlzheimer Disease | Lewy Body Disease | Retina | Optical Coherence Tomography | Cortical Atrophy | Optical Coherence Tomography Angiography | Retinal Thickening | Retinal Nerve Fibres Layer
-
NCT05856786RecruitingRefractive Errors | Myopia | Optical Coherence Tomography
-
NCT06101017CompletedCorneal Disease | Corneal Transplant Failure | Endothelial Corneal Dystrophy | Corneal Transplant Rejection