Effects of Blood Flow of Venoarterial Extracorporeal Membrane Oxygenation Life Support on Microcirculation
Effects of Adjustment of Blood Flow of Venoarterial Extracorporeal Membrane Oxygenation Life Support on Microcirculation
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Taipei, Taiwan, 110
- National Taiwan University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patients who require venoarterial extra-corporeal membrane oxygenation (ECMO) life support
Exclusion Criteria:
- who can not take an examination of sublingual microcirculation within 24 hours after placement of venoarterial ECMO support
- Non-native speakers
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Perfused small vessel density
Time Frame: Difference of PSVD between before and after adjustment of VA-ECMO blood flow within 24 hours after placement of VA-ECMO
|
Perfused small vessel density [PSVD] measured by incident dark field video microscope
|
Difference of PSVD between before and after adjustment of VA-ECMO blood flow within 24 hours after placement of VA-ECMO
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Perfused small vessel density
Time Frame: Difference of PSVD between before and after adjustment of VA-ECMO blood flow on day 2 after placement of VA-ECMO
|
Perfused small vessel density [PSVD] measured by incident dark field video microscope
|
Difference of PSVD between before and after adjustment of VA-ECMO blood flow on day 2 after placement of VA-ECMO
|
|
Perfused small vessel density
Time Frame: Difference of PSVD between before and after adjustment of VA-ECMO blood flow within anticipated 72 hours before removal of VA-ECMO
|
Perfused small vessel density measured by incident dark field video Perfused small vessel density [PSVD] measured by incident dark field video
|
Difference of PSVD between before and after adjustment of VA-ECMO blood flow within anticipated 72 hours before removal of VA-ECMO
|
|
Total small vessel density
Time Frame: Difference of TSVD between before and after adjustment of VA-ECMO blood flow within 24 hours after placement of VA-ECMO
|
Total small vessel density [TSVD] measured by incident dark field video microscope
|
Difference of TSVD between before and after adjustment of VA-ECMO blood flow within 24 hours after placement of VA-ECMO
|
|
Proportion of perfused vessel
Time Frame: Difference of PPV between before and after adjustment of VA-ECMO blood flow within 24 hours after placement of VA-ECMO
|
Proportion of perfused vessel (PPV): TSVD/PSVD X 100
|
Difference of PPV between before and after adjustment of VA-ECMO blood flow within 24 hours after placement of VA-ECMO
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 201703011RINA
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Circulatory Failure
-
NCT05919719CompletedCirculatory Failure (Shock)
-
NCT05847998CompletedShock | Acute Circulatory Failure
-
NCT03225378CompletedAcute Circulatory Failure
-
NCT04250389CompletedAcute Circulatory Failure
-
NCT02878369Unknown
-
NCT01630577CompletedAcute Circulatory Failure
-
NCT05046340RecruitingShock | Acute Circulatory Failure
-
NCT04946643CompletedAcute Circulatory Failure
-
NCT02047916CompletedCirculatory Failure in Newborn Infants
Clinical Trials on Extra-corporeal membrane oxygenation life support
-
NCT02393274CompletedHeart Failure | Respiratory Failure
-
NCT03658759WithdrawnOut-Of-Hospital Cardiac Arrest
-
NCT03857217UnknownCardiac Surgery | Cardiogenic Shock | Resuscitation
-
NCT03978728CompletedRespiratory Failure | Cardiovascular Shock
-
NCT05198986Not yet recruitingAcute Respiratory Distress Syndrome | Acute Respiratory Failure
-
NCT04031794RecruitingSevere Acute Respiratory Distress Syndrome | Refractory Hypoxemia
-
NCT00314847TerminatedMyocardial Infarction | Shock, Cardiogenic
-
NCT03813134Recruiting
-
NCT03919604Completed
-
NCT02544594Completed