Visceral Manifold and Unitary Device Study for the Repair of Thoracoabdominal Aortic Aneurysms

February 6, 2023 updated by: Patrick Kelly, Sanford Health
The primary objective of the Visceral Manifold and Unitary Device Study is to assess the use of the thoracic bifurcation and the visceral manifold or the unitary device to repair thoracoabdominal aortic aneurysms in patients having appropriate anatomy. The primary intent of the study is to assess safety and preliminary effectiveness of the device. Additionally, the study will assess technical success and treatment success at each follow-up interval.

Study Overview

Detailed Description

The primary objective of the clinical investigation Visceral Manifold and Unitary Device Study is to assess the use of the thoracic bifurcation and the visceral manifold or the unitary stent graft system to repair thoracoabdominal aortic aneurysms in patients having appropriate anatomy. The primary intent of the study is to assess safety (i.e. freedom from major adverse events (MAE) at 30 days) and preliminary effectiveness (i.e., treatment success and technical success) of the device (i.e., the proportion of treatment group subjects that achieve and maintain treatment success at one year). Additionally, the study will assess technical success and treatment success at each follow-up interval.

Study Type

Interventional

Enrollment (Anticipated)

250

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • South Dakota
      • Sioux Falls, South Dakota, United States, 57117
        • Sanford Health

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • An aneurysm with a maximum diameter of ≥ 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements
  • Aneurysm with a history of growth ≥ 0.5 cm in 6 months
  • Saccular aneurysm deemed at significant risk for rupture
  • Symptomatic aneurysm greater than or equal to 4.5 cm
  • Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit
  • Proximal landing zone for the thoracic bifurcation stent graft:

    •≥ 2.5 cm of nonaneurysmal aortic segment including previously placed graft material (neck) distal to the left subclavian artery (LSA)

    • Diameter in the range of 26-42 mm
    • Adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold
  • Proximal landing zone for the unitary manifold stent graft:

    • Nonaneurysmal aortic segment including previously placed graft material (neck) with a minimum seal zone length of 3 cm
    • Diameter in the range of 19-32 mm
  • Iliac artery or aortic distal fixation site greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm
  • Age: ≥ 18 years old
  • Life expectancy: > 1 year

Exclusion Criteria:

General exclusion

  • Patient is a good candidate for and elects for open surgical repair
  • Can be treated in accordance with the instructions for use with a legally marketed
  • Is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site
  • Unwilling to comply with the follow-up schedule
  • Inability or refusal to give informed consent
  • Urgent or emergent presentation
  • Patient is pregnant or breastfeeding
  • Patient has a contained rupture
  • Patient has a ruptured aneurysm
  • Patient has a dissection in the portion of the aorta intended to be treated
  • Obstructive stenting of any or all of the visceral vessels
  • Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)

Medical exclusion criteria

  • Known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel:Titanium), polyester, platinum-iridium, polytetrafluoroethylene (PTFE)
  • Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed
  • Uncorrectable coagulopathy
  • Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment
  • Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned < 30 days of the endovascular repair
  • Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina)
  • Systemic or local infection that may increase the risk of endovascular graft infection
  • Baseline creatinine greater than 2.0 mg/dL
  • History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome)
  • Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material

Anatomical exclusion criteria

  • Minimum branch vessel diameter less than 5 mm
  • Thrombus or excessive calcification within the neck of the aneurysm
  • Anatomy that would not allow maintenance of at least one patent hypogastric artery
  • Anatomy that would not allow primary or assisted patency of the left subclavian artery

Expanded Selection Arm Inclusion Criteria

Patient that meets the criteria for inclusion in the primary study arm but has one or more of the following criteria which would exclude them from the primary study arm:

  • Minimum branch vessel diameter less than 5 mm
  • Urgent or emergent presentation
  • Patient has a contained rupture
  • Patient has a ruptured aneurysm
  • Patient has a type B dissection (subacute or chronic) in the portion of the aorta intended to be treated
  • Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)
  • Baseline creatinine greater than or equal to 2.0 mg/dL
  • Anatomy that would not allow for maintenance of at least one hypogastric artery
  • Anatomy that would not allow for primary or assisted patency of the left subclavian artery
  • Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in the a landing zone that expands beyond any limits of the previously placed graft material
  • Obstructive stenting of any or all of the visceral vessels

OR

Patient that meets criteria for inclusion in the primary study arm and:

  • Would not be eligible for the primary study arm per a documented reason other than those outlined above, and
  • Per the opinion of the Principal Investigator, with concurrence of the IRB, alternative therapies are unsatisfactory and the probable risk of using the investigational device is no greater than the probable risk from the disease or condition.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: TREATMENT
  • Allocation: NON_RANDOMIZED
  • Interventional Model: SINGLE_GROUP
  • Masking: NONE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
EXPERIMENTAL: Primary Study Arm
The TAAA Debranching Stent Graft System is comprised of two investigational devices including the Thoracic Bifurcation and the Visceral Manifold and the Unitary Manifold. The thoracic bifurcation and the visceral manifold as well as the unitary manifold work to facilitate endovascular stenting of the visceral vessels (renals, celiac, SMA) while maintaining flow to the visceral and infrarenal segments.
Visceral Manifold and Thoracic Bifurcation Endovascular stent graft system
Unitary Manifold Endovascular stent graft system
EXPERIMENTAL: Expanded Selection Arm
The expanded selection arm is for subjects not eligible for open repair or other endovascular options due to comorbidities or anatomical limitations and do not meet inclusion in the primary study arm. The Thoracic Bifurcation and the Visceral Manifold as well as the Unitary Manifold work to facilitate endovascular stenting of the visceral vessels (renals, celiac, SMA) while maintaining flow to the visceral and infrarenal segments.
Visceral Manifold and Thoracic Bifurcation Endovascular stent graft system
Unitary Manifold Endovascular stent graft system

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Freedom from major adverse events (MAEs) at 30 days
Time Frame: 30 days
Major adverse events include death, bowel ischemia, myocardial infarction, paraplegia, renal failure, respiratory failure, and stroke.
30 days

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Treatment success and technical success at 1 year
Time Frame: 1 year

Treatment success is defined as a composite of technical success and freedom from the following:

  • Aneurysm enlargement
  • Aneurysm rupture
  • Aneurysm-related mortality
  • Conversion to open repair
  • Secondary intervention for migration, Type I and III endoleaks, device integrity failure , and patency-related events
1 year
Treatment success at various timepoints
Time Frame: 1 month, 6 months, 1 year, 2 years, 3 years, 4 years, 5 years

Treatment success and the individual components of treatment success including freedom from the following:

  • Aneurysm enlargement
  • Aneurysm-related mortality
  • Aneurysm rupture
  • Conversion to open repair
  • Secondary intervention for migration, type I and III endoleaks, device integrity failure, and patency-related events.
  • Renal failure
  • All-cause mortality
  • Endoleaks
  • Device integrity failure
  • Patency-related events
  • Other device-related events
1 month, 6 months, 1 year, 2 years, 3 years, 4 years, 5 years

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Principal Investigator: Patrick Kelly, MD, Sanford Health

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

February 1, 2015

Primary Completion (ANTICIPATED)

January 1, 2024

Study Completion (ANTICIPATED)

December 1, 2029

Study Registration Dates

First Submitted

November 14, 2014

First Submitted That Met QC Criteria

November 18, 2014

First Posted (ESTIMATE)

November 19, 2014

Study Record Updates

Last Update Posted (ACTUAL)

February 8, 2023

Last Update Submitted That Met QC Criteria

February 6, 2023

Last Verified

February 1, 2023

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Thoracoabdominal Aneurysms

Clinical Trials on Visceral Manifold and Thoracic Bifurcation

3
Subscribe