Multi-functional Neuroprosthetic System for Restoration of Motor Function in Spinal Cord Injury (NNP-UE+T)

December 17, 2025 updated by: Anne Bryden

This study is to evaluate the use of a fully implanted device for providing hand function, reach, and trunk function to individuals with cervical spinal cord injury.

Funding Sources:

FDA OOPD NIH NINDS

Study Overview

Detailed Description

The goal of this project is to restore these multiple functions to these individuals through a comprehensive neuroprosthetic approach that addresses the overall needs of the individual. This approach involves all aspects of the implementation, including the implanted technology, the surgical installation, and the outcomes assessment through a coordinated team approach in order to maximize the functional independence gained by the individual. With this system, we propose that individuals who have a mid-cervical-level spinal cord injury will regain control over multiple functions, including grasp, reach, bed mobility, seated posture, restoration of an effective cough and bladder function. This ambitious and exciting goal is made possible by the culmination of our research and clinical deployment of neuroprosthetic systems for spinal cord injured subjects over the past 30 years. We anticipate that this system will not only provide increased independence in each of the targeted body functions, but will provide enough of an overall benefit to demonstrate significant improvements in quality of life and health outcomes.

In clinical feasibility studies with spinal cord injured subjects, our clinical research teams have demonstrated the control of bilateral hand function, bed mobility, postural control, restoration of an effective cough, and bladder control using chronically implanted neuroprostheses. Outcomes from each clinical study demonstrate that each system provides increased functional independence to the individual. Initially, only a single type of implanted system was implemented in any one individual, resulting in restoration of a single bodily function. Thus, it has been necessary for subjects to choose between available functions and select only one, despite the fact that each subject had multiple disabilities. In the past few years, we have progressed to implementing a few subjects with more than one system, such as providing both hand function and trunk stability. However, the fundamental limitation of the current approach has been technological; i.e. each implanted system is completely independent (both technically and programmatically), requiring separate technology to be developed for each function, and these systems are implemented by separate teams in separate surgical procedures. Thus, to this point, it has not been possible to address each individual's comprehensive needs and tailor an overall approach that maximizes their functional gains.

The proposed approach depends on the availability of a foundational platform technology that is capable of meeting our broad specifications. We have now achieved this milestone under separate funding, creating a revolutionary new implantable neuroprosthetic technology that is fully capable of providing the necessary technological base for our proposed research. This system, the Networked Neuroprosthetic System (NNPS), is a modular, scalable, and configurable network of fully implanted, networked modules capable of meeting or exceeding the needs of all of these neuroprosthetic applications. The NNPS provides a foundation which enables efficient technical refinements that optimize implementation of the system for each targeted application. The NNPS technology is currently operational and is undergoing fabrication and testing in preparation for final pre-clinical studies and human implantation.

Study Type

Interventional

Enrollment (Estimated)

30

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

17 years and older (Child, Adult, Older Adult)

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Diagnosis of cervical level spinal cord injury, either complete or incomplete; International Standards for Neurological Classification of Spinal Cord Injury (INCSCI) motor level of C4 through C8; American Spinal Injury Impairment Scale (AIS) grade A, B, C, or D; six months or more post-injury
  • Biceps/brachialis/brachioradialis strength of 2/5 or higher on Manual Muscle Test
  • Peripheral nerve innervation to upper extremity and trunk muscles, including a grade 3/5 or higher stimulated strength (Manual Muscle Test) in at least two of the following muscles in one arm: adductor pollicis, abductor pollicis brevis, flexor pollicis longus, extensor pollicis longus, extensor digitorum communis, flexor digitorum superficialis, flexor digitorum profundus, pronator quadratus, extensor carpi ulnaris, extensor carpi radialis brevis, extensor radialis longus, flexor carpi ulnaris, flexor carpi radialis, first dorsal interosseous; and in at least two of the following muscles: left/right gluteus maximus, left/right erector spinae, left/right quadratus lumborum,
  • Age > 16 years
  • Medically stable - cleared for surgery
  • Able and willing to take part in study

Exclusion Criteria:

  • Currently pregnant (neuroprosthesis implantation delayed until no longer pregnant)
  • Other neurological conditions (multiple sclerosis, diabetes with peripheral nerve involvement)
  • History of coagulopathy, HIV, severe cardiopulmonary disease, severe bradycardia, severe autonomic dysreflexia, or chronic obstructive pulmonary disease.
  • Active untreated infection such as decubitus ulcer, urinary tract infection, pneumonia
  • Presence of other active implantable medical devices with unknown or untested interaction with the NNP implant
  • Active implantable medical device (AIMD) such as a pacemaker or defibrillator, with the exception of the implanted stimulator-telemeter (IST) or implanted receiver stimulator (IRS) systems developed by the Cleveland Functional Electrical Stimulation Center
  • Unhealed fractures that prevent functional use of arm or trunk
  • Less than six months post-injury (neuroprosthesis implantation delayed until criteria met)
  • Extensive upper extremity denervation (fewer than two stimulatable hand muscles and two stimulatable trunk muscles)
  • Involvement in other ongoing clinical studies that exclude concurrent until criteria met)
  • Disorder or condition that require MRI monitoring
  • Mechanical ventilator dependency
  • Progressive SCI In subjects who are undergoing bilateral implantation, subjects should not have a history of autonomic dysreflexia, hypertension, diabetes or any condition which requires frequent blood pressure monitoring or frequent venipuncture.
  • Adverse interaction between system components and typical electromagnetic (EM) sources in subject's home and work environments, including wheelchair or other active implantable devices.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Intervention - implant neuroprosthesis
Receives implanted networked neuroprosthetic system for hand, arm, and trunk function. Undergoes functional training and assessment.
Receive implanted networked neuroprosthesis

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Activities of Daily Living Abilities Test
Time Frame: Three months post-implant
Evaluation of ability to perform activities of daily living when using the neuroprosthesis compared to ability when the neuroprosthesis is turned off.
Three months post-implant

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Grasp-Release Test
Time Frame: Pre-implant and three months post-implant
Ability to pick up, move, and release six standard objects.
Pre-implant and three months post-implant

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

December 1, 2014

Primary Completion (Estimated)

December 31, 2028

Study Completion (Estimated)

December 31, 2031

Study Registration Dates

First Submitted

December 29, 2014

First Submitted That Met QC Criteria

December 29, 2014

First Posted (Estimated)

December 31, 2014

Study Record Updates

Last Update Posted (Estimated)

December 19, 2025

Last Update Submitted That Met QC Criteria

December 17, 2025

Last Verified

October 1, 2025

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Spinal Cord Injuries

Clinical Trials on Networked Neuroprosthetic System for Grasp and Trunk

Subscribe