- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT02610673
WiCS-LV Post Market Surveillance Registry
This is an observational, prospective, non-randomized collection of defined clinical data under normal conditions of use for the WiCS-LV System, an implantable cardiac pacing system capable of delivering pacing energy to the left ventricle of the heart without using a pacing lead.
Patients will be enrolled and followed according to standard of care for 5 years.
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
A clinical registry will be used to collect data from all implanted patients, at all follow-ups and across all implanting centers. Implant procedure will be according to the 'Instruction for Use' of the system and assessments and follow-ups according the best clinical practice.
Anonymized data will be collected on Case Report Forms (CRF) for each patient in the registry. These data will be collected at the time of implant and at scheduled patient in-clinic follow-ups of 1 week, 3 months, 6 months, and 1, 2,3,4,5 years post implant. Patients entering the registry will be given a Registry code suitable to uniquely identify the patient, the implanting center, and the responsible physician.
Data will be consolidated into a dataset by the sponsor for analysis purposes. The sponsor may request support from the center to review patient records in order to monitor the data in cases where the data appears incomplete or appears to be inaccurate.
The data set will be consolidated such that each implanting center may access its own data, or as mutually agreed between centers, aggregate data. Data may be used by centers for purposes of publication or other objectives of the center.
Study Type
Enrollment (Estimated)
Contacts and Locations
Study Locations
-
-
-
Aalborg, Denmark, 9100
- Aalborg University Hospital
-
-
-
-
-
Bernau, Germany
- Herzzentrum Brandenburg
-
-
-
-
-
Lugano, Switzerland
- Cardiocentro Ticini
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
Patients with heart failure meeting standard criteria for CRT based upon the current European Society of Cardiology / European Heart Rhythm Association (ESC/EHRA) guidelines and meeting criteria in one of these categorizations:
Untreated by conventional CRT:
This includes:
- Patients that have had an attempted but failed CS lead implant due to such complications as venous occlusion, difficult CS access or anatomy, poor lead stability or previous CS repositioning procedures.
- Patients with a previously implanted CS lead that is programmed off due to such complications as high pacing threshold, non-capture, phrenic nerve stimulation, lead failure, lead dislodgement, or other justifications due to lead issues documented by the prescribing physician.
Non-responder to conventional CRT
This includes:
• Patients with a previously implanted CRT device who based on prescribing physician judgment experience no change or worsening of heart failure symptoms or no change or worsening of NYHA functional class after 6 months of CRT treatment.
Upgrade:
This includes:
- Patients that have a relative contraindication for a CS lead implant such as difficult subclavian access, venous thrombosis, venous occlusion, risk of lead dislodgment, or other justification documented by the prescribing physician.
- Patients that have a relative contraindication for revising an implanted device to a CRT device such as previous pocket erosion, previous pocket infection, previous explantations, or other justifications documented by the prescribing physicians.
- Patients with other justifications based upon the prescribing physician's judgment of risk to reopening the device pocket including consideration for the remaining longevity of the pacemaker/ICD battery.
Exclusion Criteria:
Triple anticoagulation therapy (warfarin, clopidogrel, ASA, or other agents) Stage 4 or 5 renal dysfunction defined as GFR <30 Grade 4 mitral valve regurgitation Thrombocytopenia (platelet count <150,000) Non-ambulatory (or unstable) NYHA class 4 Contraindication to heparin Contraindication to both chronic anticoagulants and antiplatelet agents Contraindication to iodinated contrast agents Insufficient acoustic window to the LV as assessed from diagnostic transthoracic echocardiography Left atrial or left ventricular thrombus Attempted implant of a Pacemaker, ICD, or CRT device within 3 days Life expectancy < 12 months Chronic hemodialysis Myocardial infarction within one month Major cardiac surgery within one month Incompatible electrical stimulation therapy devices, for example transcutaneous electrical nerve stimulation (TENS) or other neurological stimulation devices Exposure to magnetic resonance imaging (MRI) Use of diathermy Use of therapeutic ultrasound Use of echocardiography imaging using vascular, intracardiac, Doppler, and trans-esophageal probes and systems Use of ionizing radiation treatments
-
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Complications
Time Frame: 24 hour perioperative, one month
|
Device and procedure related complications
|
24 hour perioperative, one month
|
|
Performance
Time Frame: six months
|
Bi-ventricular capture on 12 lead EKG
|
six months
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Device Complications
Time Frame: six months
|
Device and procedure related complications
|
six months
|
|
Major Complications
Time Frame: six months
|
All major complications
|
six months
|
|
Complications
Time Frame: annually to 5 years
|
Device and procedure related complications
|
annually to 5 years
|
|
Performance
Time Frame: annually to 5 years
|
Bi-ventricular capture on 12 lead EKG
|
annually to 5 years
|
|
Evidence of Efficacy
Time Frame: 6 months
|
Clinical composite score (All-cause mortality, HF hospitalizations, NYHA class, and patient global assessment)
|
6 months
|
Collaborators and Investigators
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimated)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- EBR-02821
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Cardiac Resynchronization Therapy
-
Biotronik SE & Co. KGCompletedCardiac Resynchronization Therapy | Pacemaker TherapyGermany, Austria, Spain, Switzerland
-
IRCCS Policlinico S. DonatoRecruiting
-
Monaldi HospitalUnknownCardiac Resynchronization TherapyItaly
-
Hospital Clinic of BarcelonaCompletedCardiac Resynchronization TherapySpain
-
Heart and Diabetes Center North-Rhine WestfaliaTerminatedCardiac Resynchronization TherapyGermany
-
StereotaxisTerminatedCardiac Resynchronization TherapyUnited States
-
Abbott Medical DevicesCompleted
-
Boston Scientific CorporationCompletedCardiac Resynchronization TherapyUnited States
-
Azienda Ospedaliera Universitaria Mater Domini,...CompletedCardiac Resynchronization TherapyItaly
-
Biotronik SE & Co. KGCompleted
Clinical Trials on WiCS-LV System
-
EBR Systems, Inc.CompletedHeart Diseases | Cardiovascular Diseases | Heart Failure | Cardiomyopathies | Ventricular DysfunctionDenmark, Czechia
-
EBR Systems, Inc.CompletedHeart Failure | Ventricular Dysfunction | CardiomyopathyGermany, Netherlands, France, Switzerland
-
Guy's and St Thomas' NHS Foundation TrustNational Institute for Health Research, United KingdomCompleted
-
LivaNovaTerminatedLV Lead | LV Therapy | LV Treatment | LV MicrocableFrance
-
Abbott Medical DevicesCompleted
-
Guy's and St Thomas' NHS Foundation TrustUnknown
-
Baylor Research InstituteMedtronicTerminatedCongestive Heart FailureUnited States
-
TBF Genie TissulaireTerminated
-
TBF Genie TissulaireWithdrawnCorneal Ulcer | Persistent Corneal Epithelial Defect
-
Medtronic Cardiac Rhythm and Heart FailureCompletedHeart Failure | Indications for Lead RemovalUnited States, Canada