- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT04593290
Listen Carefully: An Exploratory Study of the Association Between Listening Effort and Cognitive Function
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
This is an exploratory proof-of-concept study and an exploratory intervention study with hearing aids in the context of listening effort. With a case (MCI) and control group (cognitively healthy), investigators will examine the associations between listening effort and cognitive function and assess the effect of hearing aid use on both listening effort and cognitive function test scores for those without hearing impairment. There is not sufficient literature to support a sample size calculation for this association study. Investigators will recruit approximately 50 participants. Half of these participants (n=25) will be individuals who have been diagnosed with MCI, according to the Winblad criteria (ICD10), with a Mini Mental State Examination (MMSE) score ≤ 26. The control group of participants (n=25) will be cognitively healthy individuals. All participants will undergo both listening effort testing, coupled with pupillometry and cognitive performance testing, based on a battery of pen-and-paper neuropsychological tests.
As investigators aim to measure cognitive effort exerted when listening and understanding speech in noise, is important that all study participants exhibit a normal sensitivity threshold within the ear canal. This will be assessed using Pure Tone Audiometry (PTA).
Assessment scores for cognitive function will be recorded in a clinical setting, and will be based on a battery of pen-and-paper neuropsychological cognitive tests. The Stroop Test, Trail Making Test (part A & B), Symbol Digit Modalities Test (SDMT), Verbal Fluency Tests (category: animals and lexical), Rey Complex Figure Test and Logical Memory Test (Part A) will be administered.
The objective measure of listening effort, pupil dilation, will be recorded as a measure of task performance accuracy and pupil dilation will be measured during a SWIR test, which is used to measure speech identification and recall in varying background noise. Prior to the SWIR test, participants undergo an adaptive Danish Hearing in Noise Test (HINT), comprising a list of equally intelligible sentences to be repeated in varying decibel (dB) levels of background noise to determine the individual's speech reception threshold (SRT) at 80% correct responses.
During the SWIR test, the participant is fitted with PupilLabs' eye-tracking system, an open source system consisting of clip-in eye tracking hardware to be placed in a Virtual Reality (VR) headset. To prevent floor and ceiling effects that are independent to baseline pupil size, the illumination within the VR display is individually adapted to the individual's midpoint prior to data collection between dim (~30 lux) and bright (~230 lux), with an average illuminance of 110 lux. A software suite allows the capture and post-processing of the data feed, including pupil diameter. For the purpose of this study, the PupilLabs software is controlled via a MATLAB interface.
Everyone who participates in Part 1 (listening effort testing and cognitive testing) will be invited to participate in Part 2 (hearing aids). It is not a requirement to participate in the administration, 6-week use, and re-testing procedures involved in Part 2 of the study. All cognitively healthy participants will be invited to participate, only MCI patients with a live-in informant will be given this opportunity. After ear measurement and dome and wire length selection, Oticon Opn S 1 miniRITE hearing aid fitting will occur wirelessly using Genie software, followed by hearing aid use instructions. The fitting will use Open domes, the second generation of the National Acoustic Laboratories (NAL) fitting protocol (NAL-NL2) and will increase gain seven steps on top of Real Ear Unaided Gain (REUG) from 750 Hz to 6 kHz.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Region H
-
Copenhagen, Region H, Denmark, 2100
- Copenhagen Memory Clinic, Rigshospitalet
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
MCI group
Inclusion Criteria:
- Is 40-85 years old;
- Has no other significant neurological or psychiatric disease;
- Has normal hearing (0 - 25 dB thresholds from 250 -6 kHz) measured using PTA;
- Has normal or corrected to normal vision;
- Has an MCI diagnosis, according to Winblad criteria, with a score on the Mini Mental State Examination (MMSE) less than or equal to 26 (MMSE ≤ 26);
- Has a CDR = 0.5;
- Speaks Danish as native language
- (For part 2 of the study - hearing aid use) has a live-in informant.
Exclusion Criteria:
- Takes medication or treatment that could impact the pupillary dilation: eye drops (e.g. atropine or phenylephrine);
- Takes medication or treatment that could impact cognitive function;
- Abuses alcohol or drugs;
- Is unable to comply with study procedures.
Cognitively healthy group:
Inclusion criteria:
- Is 40-85 years old;
- Has a score above 26 on the Mini Mental State Examination (MMSE) (MMSE > 26);
- Has a CDR Global score = 0;
- Has no significant neurological or psychiatric disease;
- Has Normal hearing (0 - 25 dB thresholds from 250 -6 kHz) measured using PTA;
- Has Normal or corrected to normal vision;
- Speaks Danish as a native language.
Exclusion criteria:
- Meets the criteria for MCI (Winblad criteria) or dementia (ICD 10);
- Takes medication or treatment that could impact the pupillary dilation: eye drops (e.g. atropine or phenylephrine);
- Takes medication or treatment that could impact cognitive function;
- Abuses alcohol or drugs;
- Is unable to comply with study procedures.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: BASIC_SCIENCE
- Allocation: NON_RANDOMIZED
- Interventional Model: PARALLEL
- Masking: NONE
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
EXPERIMENTAL: Mild Cognitive Impairment (MCI)
MCI is defined as an early stage of cognitive decline that lies between normal age-matched cognitive function and the onset of very mild forms of dementia, and is associated with a slight but noticeable decline in abilities such as memory and thinking skills.
Listening effort testing (with pupillometry) and cognitive testing will be administered for this group - and after a 6-week period of hearing aid use, these measures will be re-tested.
|
Everyone who participates in Part 1 (listening effort testing and cognitive testing) will be invited to participate in Part 2 (hearing aids).
It is not a requirement to participate in the administration, 6-week use, and re-testing procedures involved in Part 2 of the study.
All cognitively healthy participants will be invited to participate, only MCI patients with a live-in informant will be given this opportunity.
After ear measurement and dome and wire length selection, Oticon Opn S 1 miniRITE hearing aid fitting will occur wirelessly using Genie software, followed by hearing aid use instructions.
The fitting will use Open domes, the standard NAL-NL2 protocol, and will increase gain seven steps on top of Real Ear Unaided Gain (REUG) from 750 Hz to 6 kHz.
|
|
ACTIVE_COMPARATOR: Cognitively Healthy
This group is 40-85 years old and has no significant neurological or psychiatric disease.
Listening effort testing (with pupillometry) and cognitive testing will be administered for this group - and after a 6-week period of hearing aid use, these measures will be re-tested.
|
Everyone who participates in Part 1 (listening effort testing and cognitive testing) will be invited to participate in Part 2 (hearing aids).
It is not a requirement to participate in the administration, 6-week use, and re-testing procedures involved in Part 2 of the study.
All cognitively healthy participants will be invited to participate, only MCI patients with a live-in informant will be given this opportunity.
After ear measurement and dome and wire length selection, Oticon Opn S 1 miniRITE hearing aid fitting will occur wirelessly using Genie software, followed by hearing aid use instructions.
The fitting will use Open domes, the standard NAL-NL2 protocol, and will increase gain seven steps on top of Real Ear Unaided Gain (REUG) from 750 Hz to 6 kHz.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Listening effort
Time Frame: Baseline, pre-intervention
|
Listening effort will be measured by the percent of correctly recalled words in the SWIR test and the time-bound pattern in the pupil dilation traces during the SWIR test.
|
Baseline, pre-intervention
|
|
The Stroop Color and Word test
Time Frame: Baseline, pre-intervention
|
Neuropsychological test extensively used to assess the ability to inhibit cognitive interference that occurs when the processing of a specific stimulus feature impedes the simultaneous processing of a second stimulus attribute, well-known as the Stroop Effect. Measure: time (seconds) and number of mistakes. Increased time corresponds to poorer performance. Increased mistakes correspond to poorer performance. |
Baseline, pre-intervention
|
|
Rey Complex Figure Test
Time Frame: Baseline, pre-intervention
|
Neuropsychological assessment, administered by trained neuropsychologist, where examinees are asked to reproduce a complicated line drawing, first by copying it freehand and then drawing it from recall. This tests both recognition and recall, and uses visuospatial abilities, memory, attention, planning, working memory and executive functions. Measure: Accuracy scores between 0 and 2 on 18 figure elements (from 0 to a maximum of 36) on both copy and delayed recall Higher score = improved performance |
Baseline, pre-intervention
|
|
Symbol-Digit Modalities Test
Time Frame: Baseline, pre-intervention
|
Neuropsychological assessment commonly used in clinical and research settings to assess neurological dysfunction. The participant has 90 seconds to pair specific numbers with given geometric figures. Like other substitution tasks, performance is underpinned by attention, perceptual speed, motor speed, and visual scanning. Measure: Total score based on number of pairings made in 90 seconds ( maximum of 110 pairings). Higher score corresponds to improved performance. |
Baseline, pre-intervention
|
|
Trail Making Test A and B
Time Frame: Baseline, pre-intervention
|
Neuropsychological test of visual attention and task switching. It consists of two parts in which the subject is instructed to connect a set of 25 dots as quickly as possible while still maintaining accuracy. Test A has participants follow numbers sequentially, while Test B has participants follow alternating numbers and letters, sequentially. The test can provide information about visual search speed, scanning, speed of processing, mental flexibility, as well as executive functioning. Measure: Test A - total time (seconds) required to connect 25 numbers, Test B - total time (seconds) required to connect 13 numbers and alphabet to letter H. Increased time corresponds to poorer performance. |
Baseline, pre-intervention
|
|
Verbal Fluency Test (category and lexical)
Time Frame: Baseline, pre-intervention
|
Participants are given 1 minute to produce as many unique words as possible within a semantic category (category fluency) or starting with a given letter (letter fluency). Category fluency tasks rely on language representations of semantic concepts, whereas lexical and action word task rely more on the central executive component of working memory. Measure: Number of unique words identified within 1 minute. More words correspond to improved performance. |
Baseline, pre-intervention
|
|
Logical Memory Test A
Time Frame: Baseline, pre-intervention
|
The Logical Memory test (part A) is a subtest of the Wechsler Memory Scale-Revised, and is a standardised assessment of narrative episodic memory. A short story is orally presented and the examinee is asked to recall the story verbatim. 25-35 minutes later, free recall of the story is again elicited (delayed recall), and a series of 30 questions are asked about the story. Measure: scores between 0 and 1 on specific pieces of the story (maximum score of 25) in both immediate and delayed recall. For the questions, a score of 0 or 1 is given to the corresponding 30 questions (maximum score of 30). Higher score corresponds to improved performance. |
Baseline, pre-intervention
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Listening effort post-hearing aid use
Time Frame: Post-intervention, after 6 weeks of intervention (hearing aid use)
|
Listening effort will be measured by the percent of correctly recalled words in the SWIR test and the time-bound pattern in the pupil dilation traces during the SWIR test.
|
Post-intervention, after 6 weeks of intervention (hearing aid use)
|
|
Logical Memory Test A post-hearing aid use
Time Frame: Post-intervention, after 6 weeks of intervention (hearing aid use)
|
The Logical Memory test (part A) is a subtest of the Wechsler Memory Scale-Revised, and is a standardised assessment of narrative episodic memory. A short story is orally presented and the examinee is asked to recall the story verbatim. 25-35 minutes later, free recall of the story is again elicited (delayed recall), and a series of 30 questions are asked about the story. Measure: scores between 0 and 1 on specific pieces of the story (maximum score of 25) in both immediate and delayed recall. For the questions, a score of 0 or 1 is given to the corresponding 30 questions (maximum score of 30). A higher score corresponds to improved performance |
Post-intervention, after 6 weeks of intervention (hearing aid use)
|
|
Verbal Fluency Test (category and lexical) post-hearing aid use
Time Frame: Post-intervention, after 6 weeks of intervention (hearing aid use)
|
Participants are given 1 minute to produce as many unique words as possible within a semantic category (category fluency) or starting with a given letter (letter fluency). Category fluency tasks rely on language representations of semantic concepts, whereas lexical and action word task rely more on the central executive component of working memory. Measure: Number of unique words identified within 1 minute. More words corresponds to improved performance. |
Post-intervention, after 6 weeks of intervention (hearing aid use)
|
|
Trail Making Test A and B - post-hearing aid use
Time Frame: Post-intervention, after 6 weeks of intervention (hearing aid use)
|
Neuropsychological test of visual attention and task switching. It consists of two parts in which the subject is instructed to connect a set of 25 dots as quickly as possible while still maintaining accuracy. Test A has participants follow numbers sequentially, while Test B has participants follow alternating numbers and letters, sequentially. The test can provide information about visual search speed, scanning, speed of processing, mental flexibility, as well as executive functioning. Measure: Test A - total time (seconds) required to connect 25 numbers, Test B - total time (seconds) required to connect 13 numbers and alphabet to letter H. Increased time corresponds to poorer performance. |
Post-intervention, after 6 weeks of intervention (hearing aid use)
|
|
Symbol-Digit Modalities Test
Time Frame: Post-intervention, after 6 weeks of intervention (hearing aid use)
|
Neuropsychological assessment commonly used in clinical and research settings to assess neurological dysfunction. The participant has 90 seconds to pair specific numbers with given geometric figures. Like other substitution tasks, performance is underpinned by attention, perceptual speed, motor speed and visual scanning. Measure: Total score based on number of pairings made in 90 seconds ( maximum of 110 pairings). Higher score corresponds to improved performance. |
Post-intervention, after 6 weeks of intervention (hearing aid use)
|
|
Rey Complex Figure Test
Time Frame: Post-intervention, after 6 weeks of intervention (hearing aid use)
|
Neuropsychological assessment where participants are asked to reproduce a complicated line drawing, first by copying it freehand and then drawing it from recall. This tests both recognition and recall, and uses visuospatial abilities, memory, attention, planning, working memory and executive functions. Measure: Accuracy scores between 0 and 2 on 18 figure elements (from 0 to a maximum of 36) on both copy and delayed recall. Higher score corresponds to improved performance. |
Post-intervention, after 6 weeks of intervention (hearing aid use)
|
|
The Stroop Color and Word test
Time Frame: Post-intervention, after 6 weeks of intervention (hearing aid use)
|
Neuropsychological test extensively used to assess the ability to inhibit cognitive interference that occurs when the processing of a specific stimulus feature impedes the simultaneous processing of a second stimulus attribute, well-known as the Stroop Effect. Measure: time (seconds) and number of mistakes. Increased time corresponds to poorer performance. Increased mistakes correspond to poorer performance. |
Post-intervention, after 6 weeks of intervention (hearing aid use)
|
Collaborators and Investigators
Sponsor
Collaborators
Investigators
- Principal Investigator: Anja Maier, Ph.D., DTU - Technical University of Denmark
Publications and helpful links
General Publications
- Livingston G, Huntley J, Sommerlad A, Ames D, Ballard C, Banerjee S, Brayne C, Burns A, Cohen-Mansfield J, Cooper C, Costafreda SG, Dias A, Fox N, Gitlin LN, Howard R, Kales HC, Kivimaki M, Larson EB, Ogunniyi A, Orgeta V, Ritchie K, Rockwood K, Sampson EL, Samus Q, Schneider LS, Selbaek G, Teri L, Mukadam N. Dementia prevention, intervention, and care: 2020 report of the Lancet Commission. Lancet. 2020 Aug 8;396(10248):413-446. doi: 10.1016/S0140-6736(20)30367-6. Epub 2020 Jul 30. No abstract available.
- Pichora-Fuller MK, Kramer SE, Eckert MA, Edwards B, Hornsby BW, Humes LE, Lemke U, Lunner T, Matthen M, Mackersie CL, Naylor G, Phillips NA, Richter M, Rudner M, Sommers MS, Tremblay KL, Wingfield A. Hearing Impairment and Cognitive Energy: The Framework for Understanding Effortful Listening (FUEL). Ear Hear. 2016 Jul-Aug;37 Suppl 1:5S-27S. doi: 10.1097/AUD.0000000000000312.
- Zekveld AA, Kramer SE, Festen JM. Cognitive load during speech perception in noise: the influence of age, hearing loss, and cognition on the pupil response. Ear Hear. 2011 Jul-Aug;32(4):498-510. doi: 10.1097/AUD.0b013e31820512bb.
- Dawes P, Emsley R, Cruickshanks KJ, Moore DR, Fortnum H, Edmondson-Jones M, McCormack A, Munro KJ. Hearing loss and cognition: the role of hearing AIDS, social isolation and depression. PLoS One. 2015 Mar 11;10(3):e0119616. doi: 10.1371/journal.pone.0119616. eCollection 2015.
- Panza F, Solfrizzi V, Logroscino G. Age-related hearing impairment-a risk factor and frailty marker for dementia and AD. Nat Rev Neurol. 2015 Mar;11(3):166-75. doi: 10.1038/nrneurol.2015.12. Epub 2015 Feb 17.
- Griffiths TD, Lad M, Kumar S, Holmes E, McMurray B, Maguire EA, Billig AJ, Sedley W. How Can Hearing Loss Cause Dementia? Neuron. 2020 Nov 11;108(3):401-412. doi: 10.1016/j.neuron.2020.08.003. Epub 2020 Aug 31.
- Feldman A, Patou F, Baumann M, Stockmarr A, Waldemar G, Maier AM, Vogel A. Listen Carefully protocol: an exploratory case-control study of the association between listening effort and cognitive function. BMJ Open. 2022 Mar 9;12(3):e051109. doi: 10.1136/bmjopen-2021-051109.
Study record dates
Study Major Dates
Study Start (ACTUAL)
Primary Completion (ACTUAL)
Study Completion (ACTUAL)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (ACTUAL)
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 19042404
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Hearing Loss
-
MED-EL Elektromedizinische Geräte GesmbHCompletedHearing Loss | Hearing Loss, Sensorineural | Hearing Loss, Bilateral | Hearing Loss, Conductive | Hearing Loss, Unilateral | Hearing Loss, MixedAustria, Germany, United Kingdom
-
Oticon MedicalCompletedEar Diseases | Hearing Loss, Conductive | Hearing Loss Mixed | Hearing Disability | Conductive Hearing Loss | Conductive Hearing Loss, Bilateral | Conductive Hearing Loss, UnilateralUnited Kingdom
-
Oticon MedicalNot yet recruitingSensorineural Hearing Loss, Bilateral | Sensorineural Hearing Loss, Severe | Sensorineural Hearing Loss, Profound
-
University of California, San FranciscoPatient-Centered Outcomes Research InstituteRecruitingHearing Loss | Hearing Loss, Sensorineural | Hearing Loss, Bilateral | Hearing Loss, Conductive | Hearing Loss, Noise-Induced | Hearing Loss, Unilateral | Hearing Loss, Mixed | Hearing Disorders in ChildrenUnited States
-
Manchester University NHS Foundation TrustUniversity of ManchesterCompletedCochlear Hearing Loss | Sensorineural Hearing Loss, BilateralUnited Kingdom
-
Truway Health, Inc.Enrolling by invitationSensorineural Hearing Loss | Tinnitus | Sudden Hearing Loss | Acoustic Trauma | Inner Ear Injury | Noise-Induced Hearing Loss | Vestibular DysfunctionUnited States
-
Envoy Medical CorporationActive, not recruitingSensorineural Hearing Loss | Sensorineural Hearing Loss (Disorder) | Sensorineural Hearing Loss, Bilateral | Sensorineural Hearing Loss, Severe | Sensorineural Hearing Loss, Profound | Sensori-Neural DeafnessUnited States
-
Oticon MedicalCompletedConductive Hearing Loss | Conductive and Sensori-neural Hearing Loss in the Same Ear | Unilateral, Profound Sensori-neural Hearing LossUnited States
-
Frequency TherapeuticsCompletedHearing Loss, Sensorineural | Presbycusis | Noise Induced Hearing Loss | Sudden Hearing LossUnited States
-
Frequency TherapeuticsCompletedHearing Loss, Sensorineural | Noise Induced Hearing Loss | Sudden Hearing LossUnited States
Clinical Trials on Oticon Opn S 1 miniRITE hearing aid
-
Cambridge University Hospitals NHS Foundation TrustWithdrawn
-
University of Southern DenmarkOdense University HospitalCompletedPresbycusis, Bilateral
-
University of WashingtonNot yet recruitingHearing Loss | Hearing Loss, Sensorineural
-
Sonova AGCompletedHearing Loss, Sensorineural | Hearing Loss, BilateralCanada
-
Sonova AGCompletedHearing Loss, Sensorineural | Hearing Loss, BilateralCanada
-
Sonova AGCompleted
-
Sonova AGCompleted
-
Sebastian GriepentrogRecruitingHearing LossSwitzerland
-
Hearts for HearingNational Institute on Deafness and Other Communication Disorders (NIDCD)RecruitingHearing Loss | Cochlear ImplantUnited States
-
University of Southern CaliforniaCompletedOral ContraceptiveUnited States