Effectiveness of the Autologous Blood Patch Method in Lung Biopsies

June 15, 2023 updated by: Burak USLU, Trakya University

Evaluation of the the Effectiveness of the Autologous Blood Patch Method in Transthoracic Lung Biopsies Using the Coaxial Technique

In this retrospective study, investigators aimed to evaluate the effectiveness of the autologous blood patch method in percutaneous transthoracic lung biopsies performed with the coaxial technique.

Study Overview

Detailed Description

In this retrospective study, investigators aimed to evaluate the effectiveness of the autologous blood patch method in percutaneous transthoracic lung biopsies performed with the coaxial technique. Biopsies and treatment modalities were performed according to approved guidelines. Ethics committee approval was obtained for the retrospective evaluation of the files and images of the participants. Written informed consent was obtained from all participants before biopsy procedures. Percutaneous transthoracic biopsies (PTB) have been started to be performed with the coaxial technique using the autologous blood patch method as of April 2019 in Interventional Radiology Department of Trakya University Hospital. All lung biopsies are performed using the blood patch method as a standard, as a clear decrease in procedural complications was observed in a short time. Thus, in this study, participants who underwent biopsy after April 2019 formed the participant group that underwent autologous blood patch, and those who had the procedure before this date formed the control group. Since autologous blood patch application was not performed before this date, participant grouping was time-dependent.

All participants included in the study underwent tru-cut biopsy with the coaxial technique. Of the 240 participants included in the study, 120 were treated with an autologous blood patch ( Group A), and the remaining 120 were participants without an autologous blood patch (Group B).

Procedure:

All biopsy procedures were performed by four interventional radiologists with at least 2 years of experience. First of all, after determining the lung lobe where the lesion was observed, axial CT images of 5 mm cross-section thickness were obtained so that the upper and lower parts of it could be visualized. After ruling the entry site in the skin, antisepsis and local anesthesia were performed. The coaxial system (17 G) was cautiously advanced and CT images were continuously evaluated to confirm entrance into the lesion. Approximately 3-4 pieces were taken with the 18 G core biopsy needle until sufficient tissue was obtained. In the autologous blood patch technique, approximately 6-7 ml of blood was taken from the participants with a 10 ml syringe before the procedure. By attaching a 3-way tap to the injector from which the blood is drawn, blood is drawn into a second injector to ensure that the clotted blood is dispersed and homogenized. After the above-mentioned procedures, and after sufficient tissue samples were taken at the last stage of the biopsy procedure, control CT imaging, including the whole lung, was performed to evaluate complications. The presences of pneumothorax were noted. The prepared autologous blood patch was given through the coaxial needle (approximately 1 ml of autologous blood patch was applied for every 1 cm when the coaxial needle was withdrawn) and the tract formed by the biopsy needle in the parenchyma, pleura, and under the skin was closed with the participant's autologous blood. Thus, it was aimed at preventing pneumothorax or reducing its severity if it occurred. The tract formed by the given autologous blood patch into the parenchyma can be observed in most biopsies. The lesion and lung parenchyma features, pneumothorax and other complications of the participants included in the study were evaluated through biopsy planning and follow-up images in hospital medical record system. It is known that transthoracic lung biopsies performed with the coaxial technique increase the diagnostic accuracy. In addition, by obtaining more than one tissue piece with a single entry, more tissue pieces can be sampled for histopathological studies as well as molecular and genetic analysis, which has become increasingly important recently. As a result, investigators think that the use of this method will increase, as more tissue material can be obtained in percutaneous transthoracic lung biopsies performed with coaxial technique and computed tomography using the autologous blood patch method, while reducing the risk of pneumothorax, the most common complication, at the same time.

Study Type

Observational

Enrollment (Actual)

240

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Edirne, Turkey
        • Trakya University

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Sampling Method

Probability Sample

Study Population

The study comprised 240 patients who received a transthoracic lung biopsy using the percutaneous coaxial technique at Trakya University Faculty of Medicine, Department of Radiology, Interventional Radiology unit, between January 1, 2015 and September 14, 2020.

Description

Inclusion Criteria:

  • Patients older than 18 years
  • Patients who underwent percutaneous transthoracic tru cut biopsy
  • Patients undergoing interventional procedures by radiologists with equal experience
  • Patients who were able to obtain sufficient samples with the applied biopsy (technical success of percutaneous transthoracic biopsy)
  • Patients whose medical records are fully accessible and whose data are reliable

Exclusion Criteria:

  • Patients whose laboratory bleeding parameters are not suitable for the procedure (platelets<100000/mm3, INR>1.5)
  • Pregnancy
  • Patients with increased risk of pneumothorax due to other etiologies (bulla, blep, chronic obstructive pulmonary disease, cystic fibrosis)
  • Patients receiving anticoagulant antiplatelet therapy
  • Patients with persistent cough
  • Patients with a history of recent lung travma, pneumothorax, hemoptysis or pulmonary hemorrhage
  • Patients with severe psychiatric diseases such as psychosis or dementia that limit cooperation with the patient
  • Patients with anatomic deformity (advanced scoliosis and kyphotic patients. Patients with pectus carinatum and pectus excavatum-like chest deformity)
  • Patients for whom tru cut biopsy is absolutely and relative contraindicated (suspected hydatid cyst or known vascular lesions such as arteriovenous malformation, pulmonary varicose, severe obstructive pulmonary disease, coagulopathy, moderate to severe pulmonary hypertension, ventilator dependence, unilateral pneumectomy)
  • Patients allergic to local anesthetic drug used for skin and subcutaneous tissue anesthesia
  • Patients who do not want to participate

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
A
The patients who underwent tru-cut biopsy with the coaxial technique and applied an autologous blood patch.
Approximately 3-4 pieces were taken with the 18 G core biopsy needle until sufficient tissue was obtained. In the autologous blood patch technique, approximately 6-7 ml of blood was taken from the patient with a 10 ml syringe before the procedure. By attaching a 3-way tap to the injector from which the blood is drawn, blood is drawn into a second injector to ensure that the clotted blood is dispersed and homogenized. The prepared autologous blood patch was given through the coaxial needle (approximately 1 ml of autologous blood patch was applied for every 1 cm when the coaxial needle was withdrawn) and the tract formed by the biopsy needle in the parenchyma, pleura, and under the skin was closed with the patient's autologous blood.
After determining the lung lobe where the lesion was observed, axial CT images of 5 mm cross-section thickness were obtained so that the upper and lower parts of it could be visualized. After ruling the entry site in the skin, antisepsis and local anesthesia were performed. The coaxial system (17 G) was cautiously advanced and CT images were continuously evaluated to confirm entrance into the lesion. Biopsy was taken and after sufficient tissue samples were taken at the last stage of the biopsy procedure, control CT imaging, including the whole lung, was performed to evaluate complications. The presences of pneumothorax were noted.
B
The patients whose true-cut biopsy with coaxial technique was taken and autologous blood patch was not applied.
After determining the lung lobe where the lesion was observed, axial CT images of 5 mm cross-section thickness were obtained so that the upper and lower parts of it could be visualized. After ruling the entry site in the skin, antisepsis and local anesthesia were performed. The coaxial system (17 G) was cautiously advanced and CT images were continuously evaluated to confirm entrance into the lesion. Biopsy was taken and after sufficient tissue samples were taken at the last stage of the biopsy procedure, control CT imaging, including the whole lung, was performed to evaluate complications. The presences of pneumothorax were noted.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Pneumothorax incidence
Time Frame: first 24 hours
Development of pneumothorax after biopsy as a complication
first 24 hours

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Chest tube placement incidence
Time Frame: Immediately after procedure
Incidence of patients needing chest tube after biopsy
Immediately after procedure

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Burak USLU, MD, Trakya University

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

October 20, 2020

Primary Completion (Actual)

November 20, 2020

Study Completion (Actual)

February 20, 2021

Study Registration Dates

First Submitted

June 1, 2023

First Submitted That Met QC Criteria

June 12, 2023

First Posted (Actual)

June 15, 2023

Study Record Updates

Last Update Posted (Estimated)

June 19, 2023

Last Update Submitted That Met QC Criteria

June 15, 2023

Last Verified

June 1, 2023

More Information

Terms related to this study

Other Study ID Numbers

  • TTLBABPTU21

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

IPD Plan Description

All patient data is stored in an institutionally encrypted medical system and cannot be shared openly.

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Pneumothorax

Clinical Trials on Autologous blood patch

Subscribe