Finding the Optimal Aim of Correction in Opening Wedge High Tibial Osteotomy

November 10, 2023 updated by: Martina Hansen's Hospital

Finding the Optimal Aim of Correction in Opening Wedge High Tibial Osteotomy Using 3D Printed Patient-specific Instrumentation (PSI). An RCT Comparing Correction Aimed at 62% Versus 55%.

The purpose of this RCT is to investigate whether high tibial osteotomy using 3D printed patient specific guides aiming at 55% correction is non-inferior to aiming at 62%.

Study Overview

Detailed Description

HTO should play a major role in modern treatment algorithms for knee overload and osteoarthritis. By transferring load from the failing/osteoarthritic compartment of the knee to a healthier compartment, HTO can delay or stop the progression of osteoarthritis at an early stage. This can remove pain and increase knee function, making return to work, activities and sport possible. HTO may delay or avoid the need for total knee replacement for >10 years for at least 80% of patients.

The optimal target for the postoperative mechanical axis of the leg is not yet clarified. Both under- and overcorrection can lead to unfavourable results. The classical Fusjisawa´s point of 62%, or approximately 3 deg. of valgus, is still often used as the optimal target, and studies show good clinical results and longevity. With an often accepted accuracy of +/- 3 deg. with conventional methods, the accepted postoperative range of valgus will be from 0 deg. to 6 deg. But the optimal range is possibly much narrower. Recent studies suggest a narrower range and less overcorrection.

3D-printed patient specific instrumentation (PSI) is based on CT of the individual patient´s knee, data simulation of the planned correction and subsequent 3D printed guides for each patient. The PSI design varies, but involves a positioning guide fitting only in position one the proximal tibia, a cutting guidance and a wedge opening guide. PSI seem to improve accuracy to the level of approximately +/- 1 deg. from the preplanned correction and leads to fewer unacceptable outliers compared to the conventional methods available. Improved accuracy has not shown to yield better clinical results.

In the future the target axis should possibly be individualized, based on the pathology treated, gait analyses and data simulations.

Modern gait analysis using wearable accelerator sensors, often referred to as inertial measurement units (IMUs) is rapidly evolving. By coupling individualized and accurate osteotomy with gait analysis using wearable sensors, one could better predict and understand how to normalise each individual patients´ gait pattern and possibly improve patient satisfaction and function after surgery.

By coupling the highly accurate PSI method, an angular stable implant and a composite of outcomes based on radiology, validated patient reported outcome measures and gait analysis, our RCT can investigate if a correction target of 55% is non-inferior to the common 62%.

The study will be designed as a continuous outcome non-inferiority trial where KOOS QoL subscale is used as the primary outcome and the basis for sample size calculation. The Minimal Clinical Important Difference (MCID) for KOOS QoL regarding HTO is 16.5 points. A presumed standard deviation (SD) of 23 points is obtained from a previous study on a similar population. A one-sided t-test power analysis with 2.5% significance level and 80% power level indicates that 31 patients would be needed in each group. In total 70 patients is planned to be included, which takes into account up to 10% dropout rate and some uncertainty regarding the predicted score values.

Statistics:

The primary outcome will be analyzed with a linear mixed model, where the measurements from all time points will be included. The main effect measure will be the between-group difference in change from baseline to two years, which will be estimated with a 95% confidence interval and a P-value for non-inferiority where the null hypothesis is that osteotomy correction to the 55% target is inferior to the correction to the 62% target and the alternative states that it is not. Inferiority is determined by KOOS QOL difference of at least MCID.

Paired samples t-tests will be used to analyze differences between pre- and postoperative measurements on X-rays within each group. Independent samples t-tests will be used to analyze differences between groups. A p-value < 0.05 is considered statistically significant.

Study Type

Interventional

Enrollment (Estimated)

70

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Contact Backup

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Patients having accepted and signed the informed consent form before surgery
  • Patients aged 30-60 years
  • Patients with an indication for primary HTO based on anamnestic, clinical and radiological findings leading to the diagnosis of major medial knee compartment overload symptoms
  • Mechanical varus axis of 3-9 deg. (calculated on full length weightbearing X-ray (FLWB))
  • Correctable angular deformity on the tibia only (medial proximal tibial angle (MPTA) + planned correction < 95 deg. Lateral distal femoral angle (LDFA) <92 deg.)
  • Maximal calculated gap height 14 mm
  • Only the first knee will be included if later contralateral HTO

Exclusion Criteria:

  • Inflammatory arthritis (Rheumatoid Arthritis, Bechterew arthritis, Psoriatic Arthritis)
  • Patients using Prednisolone perorally
  • Smokers (need to quit preoperatively)
  • Significant overweight (Body Mass Index > 35)
  • Earlier fractures in affected leg with fracture malalignment >5 deg.
  • Extension deficit >10 deg. in the affected knee
  • Earlier septic arthritis/osteomyelitis in the affected leg
  • Previous major surgery affecting leg function. Earlier knee arthroscopic procedures like ACL-reconstruction are not excluded
  • Planned combined procedures involving HTO + ACL/PCL-reconstruction, meniscal transplantation or meniscal root fixation is excluded
  • Neurologic disease with symptoms affecting the leg
  • Serious illness or other factors that make communication, follow-up or rehabilitation difficult (e.g. alcohol or drug abuse, psychiatric disease, non-Norwegian speakers).

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Triple

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: 55% correction
HTO using PSI targeted at 55% correction axis
HTO using PSI designed to achieve correction to 55% tibial width.
Active Comparator: 62% correction
HTO using PSI targeted at 62% correction axis
HTO using PSI designed to achieve correction to 62% tibial width.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Knee injury and Osteoarthritis Outcome Score subscore Quality of Life (KOOS QOL), 0-100, 100 best score
Time Frame: 24 months
Knee related Quality of Life
24 months

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Knee injury and Osteoarthritis Outcome Score 12 Short form (KOOS-12), 0-100, 100 best score
Time Frame: 24 months
Knee related pain, symptoms, ADL, QoL and function
24 months
Forgotten Joint Score-12(FJS-12), 0-100, 100 best score
Time Frame: 24 months
Knee related symptoms and function
24 months
EuroQol-5D (EQ-5D), index 0-1, 1 best score
Time Frame: 24 months
Health related quality of life
24 months
University of California at Los Angeles activity level (UCLA), 0-10, 10 most active
Time Frame: 24 months
Activity level score
24 months
Ground contact time (milliseconds)
Time Frame: 24 months
Accelerometer based gait analysis
24 months

Other Outcome Measures

Outcome Measure
Measure Description
Time Frame
HKA X-ray measures (Standing Hip-Knee-Ankle x-ray)
Time Frame: 6 months
MPTA/JLCA/LDFA/HKA angles
6 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Tor Kjetil Nerhus, MD, PhD, Martina Hansens Hospital

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

November 1, 2023

Primary Completion (Estimated)

October 1, 2026

Study Completion (Estimated)

October 1, 2028

Study Registration Dates

First Submitted

June 23, 2023

First Submitted That Met QC Criteria

November 10, 2023

First Posted (Estimated)

November 16, 2023

Study Record Updates

Last Update Posted (Estimated)

November 16, 2023

Last Update Submitted That Met QC Criteria

November 10, 2023

Last Verified

November 1, 2023

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Arthralgia

Subscribe