Noční polysomnografie a monitor dechového objemu

30. září 2026 aktualizováno: Tufts Medical Center

Vyhodnocení monitoru dechového objemu u pacientů podstupujících noční polysomnografii

Sleep disordered breathing; specifically obstructive sleep apnea (OSA) is a disease affecting 8-12% of the general population and often more than 70% of the bariatric surgical population. OSA is characterized by the repetitive collapse of the upper airway, causing a reduction or cessation in airflow and decreases in oxygen saturation. These events are resolved by arousals from sleep, reducing sleep quality and leading to excessive daytime sleepiness. An in-laboratory polysomnography (PSG) is the gold standard for the diagnosis of OSA.

Previous studies have established obstructive sleep apnea (OSA) as a potential independent risk factor for postoperative complications, adverse surgical outcomes, and longer hospital stays.

Patients with OSA have an increase in postoperative complications, the most frequent being oxygen desaturation, postoperative atelectasis and increased postoperative pain. Despite the clear risks, OSA remains under diagnosed with an estimated 25-30% of patients at a high risk for OSA. It has been suggested that OSA events may be even more frequent post operatively because of the residual effects of anesthesia and the use of potent pain medications such as opioids. Postoperatively apneas often go undetected and untreated. The use of supplemental O2 may mask any desaturations and there is no convenient technology to noninvasively monitor ventilation to detect apnea and hypopnea in post-surgical patients.

New advances in technology and digital signal processing have led to the development of an impedance based Respiratory Volume Monitor (RVM). The RVM (ExSpiron™, Respiratory Motion, Inc.; Waltham, MA) has been shown to provide accurate real-time, continuous, non-invasive measurements of tidal volume (TV), minute ventilation (MV) and respiratory rate (RR). Our main hypotheses are that the non-invasive, impedance-based RVM monitor will accurately reflect TV, RR and MV during sleep and will detect apneas and hypopneas accurately.

Přehled studie

Postavení

Aktivní, ne nábor

Detailní popis

This is an observational pilot study to evaluate the clinical applicability of the ExSpiron Respiratory Volume Monitor (RVM) in patients with suspected sleep apnea. Previous work has demonstrated the ability of the RVM to provide non-invasive, real-time, continuous measurements of respiratory parameters (MV, TV, and RR) but those studies have not specifically looked at patients during sleep or patients with sleep disordered breathing.

Previously there was no device capable of providing, continuous, non-invasive, real time measurements of ventilatory status such as minute ventilation, tidal volume and RR. The ExSpiron system utilizing impedance based technology and proprietary algorithms (Respiratory Motion Inc., Waltham, MA) have been developed to obtain these measurements.

Respiratory Motion, Inc. has previously evaluated ExSpiron measurements of respiratory parameters (MV, TV and RR) in studies of adult volunteer subjects. Stimulus leads delivered an alternating minimal current (1.5 mA) at a frequency of 50 kHz and recording leads recorded differential voltages to calculate impedance. Subject data (height, weight, age, gender, chest circumference) were measured. The studies showed that using the optimal lead placement configuration, algorithms based on chest wall impedance and respiratory pattern analysis provided provided RVM measurements and ExSpiron curves which correlated strongly with spirometry volumes and spirometry curves.

A large percentage of patients in the general surgical population have undiagnosed OSA. This population is at increased risk of adverse perioperative respiratory complications. Assessment and management of perioperative respiratory function and early intervention when indicated is a multifaceted, complex task often complicated by the unavailability of an accurate and continuous monitoring system that can demonstrate apnea and hypopnea to guide clinical decision making. The ExSpiron system is designed for these patients and is intended to address some of the limitations of the current generation of hospital monitors as listed below:

In the, non-ventilated patient, current monitoring devices do not provide objective non-invasive, continuous real time measurements of important respiratory parameters MV, TV and RR that reflect respiratory competence, nor do they provide adequate assessment of apnea and hypopnea.

Current monitoring of non-intubated patients mostly relies on oximetry data, subjective clinical assessment which measures respiration and not ventilation and rarely transcutaneous CO2 measurements. In appropriate clinical settings, the ExSpiron system can provide direct quantitative measure of ventilation (MV, TV and RR) that can be used in the detection of apnea and hypopnea.

Precise apnea and hypopnea assessment.

Most if not all of the gaps left by current respiratory assessment technologies may be filled by a non-invasive monitor such as the one proposed for use in this study. There are many potential applications for this technology including: use in peri-procedural environment to evaluate the effects of medication on ventilation and detection of apnea/hypopnea. In addition, it may be useful in clinical decision making regarding medication adjustments of pain management protocols, evaluation ventilatory status prior to extubation and evaluation of the need for reintubation, but also trending of respiratory patterns to avoid risky emergency airway management interventions.

New advances in technology and digital signal processing have led to the development of an impedance based Respiratory Volume Monitor (RVM). The RVM (ExSpiron™, Respiratory Motion, Inc.; Waltham, MA) has been shown to provide accurate real-time, continuous, non-invasive measurements of tidal volume (TV), minute ventilation (MV) and respiratory rate (RR). Our main hypotheses are that the non-invasive, impedance-based RVM monitor will accurately reflect TV, RR and MV during sleep and will detect apneas and hypopneas accurately.

Main Hypothesis: The ExSpiron monitor accurately reflects apnea and hypopnea events compared to standard polysomnography. The ExSpiron monitor is able to distinguish between central and obstructive apneic events.

Secondary Hypothesis: 1) Correlation of MV% as compared to % predicted with comorbidities (e.g. hypertension and metabolic syndrome), 2)Correlation of MV changes as compared to MV% predicted with oxygen desaturation index (ODI), 3) evaluation breathing patterns before and after obstruction, 4) evaluation of breathing patterns in different types of apnea (central, obstructive and mixed).

Typ studie

Pozorovací

Zápis (Odhadovaný)

80

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • Massachusetts
      • Boston, Massachusetts, Spojené státy, 02111
        • Tufts Medical Center

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

18 let a starší (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Všechno

Metoda odběru vzorků

Vzorek nepravděpodobnosti

Studijní populace

All adult patients referred to the sleep laboratory at Tufts Medical Center for a standard polysomnogram (PSG) are eligible to be recruited.

Popis

Inclusion Criteria:

  • Adult Patients referred to the sleep lab for a polysomnography for suspicion of sleep disordered breathing aged ≥ 18 years. Ability to provide written informed consent.

Exclusion Criteria:

- Patients not competent to give informed consent, patients with implantable electronic devices, such as pacemakers, stimulators, etc. pregnant or lactating women.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Observační modely: COHORT
  • Časové perspektivy: PROSPECTIVE

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Časové okno
Shoda mezi počtem a trváním příhod apnoe měřených jako AHI (index apnoe hypopnoe) hodnocené standardní polysomnografií oproti monitoru Exspiron
Časové okno: Délka polysomnografické studie, obvykle 1 hodnocení přes noc
Délka polysomnografické studie, obvykle 1 hodnocení přes noc

Sekundární výstupní opatření

Měření výsledku
Časové okno
Schopnost monitoru Exspiron rozlišovat mezi centrální a obstrukční apnoe. Pro toto srovnání neexistuje žádná jednotka měření
Časové okno: Délka polysomnografické studie, obvykle 1 hodnocení přes noc
Délka polysomnografické studie, obvykle 1 hodnocení přes noc

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Spolupracovníci

Vyšetřovatelé

  • Vrchní vyšetřovatel: Roman Schumann, MD, Tufts Medical Center

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

1. června 2013

Primární dokončení (Odhadovaný)

31. prosince 2027

Dokončení studie (Odhadovaný)

31. července 2028

Termíny zápisu do studia

První předloženo

26. září 2014

První předloženo, které splnilo kritéria kontroly kvality

19. listopadu 2014

První zveřejněno (Odhadovaný)

20. listopadu 2014

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

5. října 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

30. září 2026

Naposledy ověřeno

1. září 2026

Více informací

Termíny související s touto studií

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .