Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Overnight polysomnography og respiratorisk volumenmonitor

30. september 2026 opdateret af: Tufts Medical Center

Evalueringen af ​​en respiratorisk volumenmonitor hos patienter, der gennemgår polysomnografi natten over

Sleep disordered breathing; specifically obstructive sleep apnea (OSA) is a disease affecting 8-12% of the general population and often more than 70% of the bariatric surgical population. OSA is characterized by the repetitive collapse of the upper airway, causing a reduction or cessation in airflow and decreases in oxygen saturation. These events are resolved by arousals from sleep, reducing sleep quality and leading to excessive daytime sleepiness. An in-laboratory polysomnography (PSG) is the gold standard for the diagnosis of OSA.

Previous studies have established obstructive sleep apnea (OSA) as a potential independent risk factor for postoperative complications, adverse surgical outcomes, and longer hospital stays.

Patients with OSA have an increase in postoperative complications, the most frequent being oxygen desaturation, postoperative atelectasis and increased postoperative pain. Despite the clear risks, OSA remains under diagnosed with an estimated 25-30% of patients at a high risk for OSA. It has been suggested that OSA events may be even more frequent post operatively because of the residual effects of anesthesia and the use of potent pain medications such as opioids. Postoperatively apneas often go undetected and untreated. The use of supplemental O2 may mask any desaturations and there is no convenient technology to noninvasively monitor ventilation to detect apnea and hypopnea in post-surgical patients.

New advances in technology and digital signal processing have led to the development of an impedance based Respiratory Volume Monitor (RVM). The RVM (ExSpiron™, Respiratory Motion, Inc.; Waltham, MA) has been shown to provide accurate real-time, continuous, non-invasive measurements of tidal volume (TV), minute ventilation (MV) and respiratory rate (RR). Our main hypotheses are that the non-invasive, impedance-based RVM monitor will accurately reflect TV, RR and MV during sleep and will detect apneas and hypopneas accurately.

Studieoversigt

Status

Aktiv, ikke rekrutterende

Detaljeret beskrivelse

This is an observational pilot study to evaluate the clinical applicability of the ExSpiron Respiratory Volume Monitor (RVM) in patients with suspected sleep apnea. Previous work has demonstrated the ability of the RVM to provide non-invasive, real-time, continuous measurements of respiratory parameters (MV, TV, and RR) but those studies have not specifically looked at patients during sleep or patients with sleep disordered breathing.

Previously there was no device capable of providing, continuous, non-invasive, real time measurements of ventilatory status such as minute ventilation, tidal volume and RR. The ExSpiron system utilizing impedance based technology and proprietary algorithms (Respiratory Motion Inc., Waltham, MA) have been developed to obtain these measurements.

Respiratory Motion, Inc. has previously evaluated ExSpiron measurements of respiratory parameters (MV, TV and RR) in studies of adult volunteer subjects. Stimulus leads delivered an alternating minimal current (1.5 mA) at a frequency of 50 kHz and recording leads recorded differential voltages to calculate impedance. Subject data (height, weight, age, gender, chest circumference) were measured. The studies showed that using the optimal lead placement configuration, algorithms based on chest wall impedance and respiratory pattern analysis provided provided RVM measurements and ExSpiron curves which correlated strongly with spirometry volumes and spirometry curves.

A large percentage of patients in the general surgical population have undiagnosed OSA. This population is at increased risk of adverse perioperative respiratory complications. Assessment and management of perioperative respiratory function and early intervention when indicated is a multifaceted, complex task often complicated by the unavailability of an accurate and continuous monitoring system that can demonstrate apnea and hypopnea to guide clinical decision making. The ExSpiron system is designed for these patients and is intended to address some of the limitations of the current generation of hospital monitors as listed below:

In the, non-ventilated patient, current monitoring devices do not provide objective non-invasive, continuous real time measurements of important respiratory parameters MV, TV and RR that reflect respiratory competence, nor do they provide adequate assessment of apnea and hypopnea.

Current monitoring of non-intubated patients mostly relies on oximetry data, subjective clinical assessment which measures respiration and not ventilation and rarely transcutaneous CO2 measurements. In appropriate clinical settings, the ExSpiron system can provide direct quantitative measure of ventilation (MV, TV and RR) that can be used in the detection of apnea and hypopnea.

Precise apnea and hypopnea assessment.

Most if not all of the gaps left by current respiratory assessment technologies may be filled by a non-invasive monitor such as the one proposed for use in this study. There are many potential applications for this technology including: use in peri-procedural environment to evaluate the effects of medication on ventilation and detection of apnea/hypopnea. In addition, it may be useful in clinical decision making regarding medication adjustments of pain management protocols, evaluation ventilatory status prior to extubation and evaluation of the need for reintubation, but also trending of respiratory patterns to avoid risky emergency airway management interventions.

New advances in technology and digital signal processing have led to the development of an impedance based Respiratory Volume Monitor (RVM). The RVM (ExSpiron™, Respiratory Motion, Inc.; Waltham, MA) has been shown to provide accurate real-time, continuous, non-invasive measurements of tidal volume (TV), minute ventilation (MV) and respiratory rate (RR). Our main hypotheses are that the non-invasive, impedance-based RVM monitor will accurately reflect TV, RR and MV during sleep and will detect apneas and hypopneas accurately.

Main Hypothesis: The ExSpiron monitor accurately reflects apnea and hypopnea events compared to standard polysomnography. The ExSpiron monitor is able to distinguish between central and obstructive apneic events.

Secondary Hypothesis: 1) Correlation of MV% as compared to % predicted with comorbidities (e.g. hypertension and metabolic syndrome), 2)Correlation of MV changes as compared to MV% predicted with oxygen desaturation index (ODI), 3) evaluation breathing patterns before and after obstruction, 4) evaluation of breathing patterns in different types of apnea (central, obstructive and mixed).

Undersøgelsestype

Observationel

Tilmelding (Anslået)

80

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Massachusetts
      • Boston, Massachusetts, Forenede Stater, 02111
        • Tufts Medical Center

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Prøveudtagningsmetode

Ikke-sandsynlighedsprøve

Studiebefolkning

All adult patients referred to the sleep laboratory at Tufts Medical Center for a standard polysomnogram (PSG) are eligible to be recruited.

Beskrivelse

Inclusion Criteria:

  • Adult Patients referred to the sleep lab for a polysomnography for suspicion of sleep disordered breathing aged ≥ 18 years. Ability to provide written informed consent.

Exclusion Criteria:

- Patients not competent to give informed consent, patients with implantable electronic devices, such as pacemakers, stimulators, etc. pregnant or lactating women.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Observationsmodeller: COHORT
  • Tidsperspektiver: PROSPECTIVE

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Tidsramme
Overensstemmelse mellem antallet og varigheden af ​​apnøhændelser målt som AHI (apnø hypopnøindeks) vurderet ved standard polysomnografi versus Exspiron monitor
Tidsramme: Varighed af polysomnografiundersøgelse, normalt 1 vurdering natten over
Varighed af polysomnografiundersøgelse, normalt 1 vurdering natten over

Sekundære resultatmål

Resultatmål
Tidsramme
Exspiron-monitorens evne til at skelne mellem centrale og obstruktive apnøhændelser. Der er ingen enhedsmåling til denne sammenligning
Tidsramme: Varighed af polysomnografiundersøgelse, normalt 1 vurdering natten over
Varighed af polysomnografiundersøgelse, normalt 1 vurdering natten over

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Samarbejdspartnere

Efterforskere

  • Ledende efterforsker: Roman Schumann, MD, Tufts Medical Center

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

1. juni 2013

Primær færdiggørelse (Anslået)

31. december 2027

Studieafslutning (Anslået)

31. juli 2028

Datoer for studieregistrering

Først indsendt

26. september 2014

Først indsendt, der opfyldte QC-kriterier

19. november 2014

Først opslået (Anslået)

20. november 2014

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

5. oktober 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

30. september 2026

Sidst verificeret

1. september 2026

Mere information

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner