Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Effectiveness of VistaO2 Device in Screening of Sleep Apnea/Hypopnea Syndrome (VISTAO2)

The high prevalence (9% in men and 4% in women) of sleep apnea / hypopnea syndrome (SAHS) in adults is now well documented as well as its cardiovascular repercussions. Previous studies showed a conclusive link between SAHS and severe cardiovascular diseases such as hypertension, myocardial infarction, heart failure and stroke.Then, SAHS is a public health issue in adults.

In this context, early detection of such a disease is crucial if the management is tailored to the patient, the practitioner's choice of therapy moving towards continuous positive airway pressure (CPAP) or mandibular advancement device. The detection is based on full nocturnal polysomnography or polygraphic recordings. Polysomnography remains the gold standard but it is a time consuming and costly examination. Polygraphic recording is a test that allows simplified the diagnosis of severe patients, but may not be sufficient for mild form of SAHS. Thus, the SAHS is a pathology under-diagnosed and under-treated. The validation of a technique for identifying patients most at risk to either limit the number of polysomnographic examination is requested.

Studieoversigt

Status

Afsluttet

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

In this perspective, the development of a product screening sleep related breathing disorders for physicians, cardiologists, internists (not specialized sleep experts) would fill this need. It allows for a reliable first screening for their patients in parallel with a routine cardiological examination. Imposing a minimal human and material, the ECG Holter recorder "VistaO2" (NOVACOR, Rueil-Malmaison, France) is a device designed to meet these requirements. This device fits into the daily management of patients with cardiac arrhythmias or sinus/atrioventricular conduction disorders, and of patients suffering myocardial infarction (arrhythmic risk stratification, detection of silent myocardial ischemia).

Analysis of heart rate variability (HRV) has already shown interest in screening SAHS. We therefore wish to evaluate the performance of the analysis of data from the screening tool VistaO2 face what the gold standard synchronized polysomnography.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

182

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Paris, Frankrig, 75000
        • Hôpital Tenon - APHP
      • Saint-etienne, Frankrig, 42055
        • CHU de Saint-Etienne

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år til 80 år (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • sleep apnea hypopnea syndrome suspicion
  • written consent

Exclusion Criteria:

  • pacemaker
  • diabetes
  • atrial fibrillation
  • electrode allergy

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Diagnostisk
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: VistaO2 device
This device combines the transcutaneous oxyhemoglobin saturation (allowing to compute the oxyhemoglobin desaturation index), the slow variations in heart rate and an index of nocturnal respiratory events calculated by analyzing the movements of the chest performed by chest impedance variations.
Full night VistaO2 device monitoring synchronized with the gold standard polysomnography.
Andre navne:
  • VistaO2 : ECG Holter recorder (Novacor, Rueil-Malmaison, France).

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Søvnapnø hypopnø syndrom
Tidsramme: Dag 1
Apnø hypopnø-indeks højere end 15, vurderet ved polysomnografi.
Dag 1

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. februar 2009

Primær færdiggørelse (Faktiske)

1. januar 2011

Studieafslutning (Faktiske)

1. januar 2011

Datoer for studieregistrering

Først indsendt

25. maj 2010

Først indsendt, der opfyldte QC-kriterier

31. maj 2010

Først opslået (Skøn)

2. juni 2010

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Skøn)

21. juli 2011

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

20. juli 2011

Sidst verificeret

1. juli 2011

Mere information

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Søvnapnø syndromer

Kliniske forsøg med VistaO2 device

3