Fractional flow reserve (FFR) measurement involves determining the ratio between the maximum achievable blood flow in a diseased coronary artery and the theoretical maximum flow in a normal coronary artery. An FFR of 1.0 is widely accepted as normal. An FFR value lower than 0.75 - 0.80 is generally considered to be associated with myocardial ischemia (MI).
FFR is easily measured during routine coronary angiography by using a pressure wire to calculate the ratio between coronary pressure distal to a coronary artery stenosis and aortic pressure under conditions of maximum myocardial hyperemia. This ratio represents the potential decrease in coronary flow distal to the coronary stenosis.
Over the past decade, FFR measurement has been increasingly used in cardiac catheterization laboratories. It provides a quantitative assessment of the functional severity of a coronary artery stenosis identified during coronary angiography and cardiac catheterization.
Opsens, Inc. has developed a new pressure wire for use in determining FFR in coronary arteries; the OptoWire. The OptoWire is an instrumented guide wire with a fiber optic pressure sensor mounted 3.5 cm proximal to the tip. The Optowire measures blood pressure during diagnostic and/or interventional procedures when used in combination with the OptoMonitor.
The O2 study is a pilot study which aims to provide preliminary experience in human patients with coronary artery disease. The study data will also be used as part of design validation.
The O2 study is a prospective single arm study designed to assess the usability, functionality, and safety of the Optowire and Optomonitor in patients.
Tanulmány típusa
Beiratkozás (Tényleges)
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi helyek
-
-
-
Quebec, Kanada, G1V 4G5
- IUCPQ - Laval Hospital
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Leírás
Inclusion Criteria:
Patients with
- Stable angina or,
- Unstable angina pectoris or,
- Atypical chest pain or no chest pain but with suspected ischemia
- At least one moderate lesion in native coronary artery thought to produce ischemia
- Operator and patient agree for procedures
- Patient (> 18 years) has signed a written informed consent prior to procedure
Exclusion Criteria:
- Lesions with angiographic 'haziness' or suspected to contain thrombus
- Post-coronary artery bypass grafting
- Total occlusion
- If use of atherectomy device is indicated
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Diagnosztikai
- Kiosztás: N/A
- Beavatkozó modell: Egyetlen csoportos hozzárendelés
- Maszkolás: Nincs (Open Label)
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
---|---|
Kísérleti: Fractional flow reserve
Fractional flow reserve measurement
|
Fractional flow reserve measurement
Más nevek:
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
---|---|---|
Safety and handling assessment of the Optowire
Időkeret: Patients will be followed through removal of the OptoWire from percutaneous insertion site and completion of the cardiac catheterization procedure (expected average <1hr)
|
Dedicated questionnaires will be used for such assessment |
Patients will be followed through removal of the OptoWire from percutaneous insertion site and completion of the cardiac catheterization procedure (expected average <1hr)
|
Másodlagos eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
---|---|---|
Comparison of FFR values measured with Optowire vs. with FFR guide wire used in standard practice
Időkeret: Patients will be followed through removal of the OptoWire from percutaneous insertion site and completion of the cardiac catheterization procedure (expected average <1hr)
|
In selected cases, the operator may choose to perform FFR measurements using currently approved FFR wires.
Values obtained with standard FFR wires and Optowire may therefore be compared.
|
Patients will be followed through removal of the OptoWire from percutaneous insertion site and completion of the cardiac catheterization procedure (expected average <1hr)
|
Együttműködők és nyomozók
Szponzor
Együttműködők
Nyomozók
- Kutatásvezető: Olivier F Bertrand, MD PhD, International Chair on Interventional Cardiology and Transradial Approach
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete
Elsődleges befejezés (Tényleges)
A tanulmány befejezése (Tényleges)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Becslés)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Becslés)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
Kulcsszavak
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- O2 Pilot Study
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .
Klinikai vizsgálatok a Fractional flow reserve measurement
-
Stanford UniversityUniversity of California, Irvine; Catharina Ziekenhuis Eindhoven; Medtronic; Abbott... és más munkatársakAktív, nem toborzóKoszorúér-betegség | Koszorúér-szűkületEgyesült Királyság, Koreai Köztársaság, Hollandia, Új Zéland, Svédország, Norvégia, Dánia, Egyesült Államok, Ausztrália, Litvánia, Szerbia, Kanada, Belgium, Csehország, Franciaország, Magyarország
-
Shanghai Zhongshan HospitalBefejezve
-
Portuguese Society of CardiologyAbbott Medical DevicesIsmeretlenA koszorúér-betegség | Szívbillentyű-betegségPortugália