- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT02858323
Legame del complemento (C1q) agli anticorpi HLA in un test immunologico in fase solida ed effetto clinico sulla trasfusione piastrinica
Background:
Platelets are blood cells that help blood clot. Some people have what is called thrombocytopenia. This means they have a low blood platelet count. They need platelet transfusions very often. Human leukocyte antigen (HLA) alloimmunization occurs for a lot of these people. They become refractory. This means their platelet levels no longer increase after transfusions. Researchers want to study a procedure that detects HLA antibodies. They want to test how well it predicts how a person will respond to a transfusion. They want to see if it does this better than the procedure that is usually used.
Objective:
To study the effect of C1q-binding of Class I HLA antibodies on platelet refractoriness in people who get platelet transfusions. To test if this method better predicts response to platelet transfusion than the IgG solid phase immunoassay method.
Eligibility:
People enrolled on protocols 11-C-0136, 08-H-0156, 03-C-0277, 01-C-0157, or 01-C-0129 who:
Agreed to have their specimens and data used for future research
Had Class I HLA antibodies detected by the IgG method
Had one or more platelet transfusions at NIH after the first positive HLA IgG antibody result
Design:
For each participant, researchers will look at a small portion of their archived plasma sample. The samples were left over from prior HLA antibody tests.
Participants samples will be analyzed. They will be tested to see if C1q-binding HLA antibodies are present. This will be done by solid phase immunoassay. Results will be compared with the past results of the IgG method.
Participants data will be stored in database that s protected by password.
...
Panoramica dello studio
Stato
Descrizione dettagliata
Human leukocyte antigen (HLA) alloimmunization is common in patients undergoing frequent platelet transfusion, and is the most important cause of immune platelet refractoriness. Management strategies in HLA alloimmune platelet-refractory patients include transfusion with HLA-matched or crossmatched platelets; however, in broadly-sensitized patients, or in patients with uncommon HLA types, antigen-negative or epitope compatible donors may be difficult to find.
The Luminex immunoglobulin (Ig)G single-antigen-bead (SAB) solid phase immunoassay is now commonly used to detect HLA antibodies. However, an assay that specifically detects C1qbinding to HLA antibodies has been reported to identify a clinically relevant subset of HLA antibodies in solid organ transplantation; one group has studied the utility of this assay in platelet transfusion of HLA-alloimmunized platelet refractory patients. We intend to evaluate the ability of this C1-binding immunoassay to predict response to platelet transfusion in HLA alloimmune patients.
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
Maryland
-
Bethesda, Maryland, Stati Uniti, 20892
- National Institutes of Health Clinical Center
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Descrizione
-
INCLUSION CRITERIA:
- Class I HLA antibodies detected by the IgG solid phase immunoassay method
- Greater than or equal to 1 episode of platelet transfusion at NIH after the first positive HLA IgG antibody result
EXCLUSION CRITERIA:
1) Hyperproliferative thrombocytopenia
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: COHORT
- Prospettive temporali: RETROSPECTIVE
Coorti e interventi
Gruppo / Coorte |
|---|
|
1
Previously selected HLA-alloimmunized platelet refractory, clinical, patients. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Corrected count increment after platelet transfusion
Lasso di tempo: Retrospective
|
Corrected Count Increment |
Retrospective
|
Collaboratori e investigatori
Investigatori
- Investigatore principale: Willy A Flegel, M.D., National Institutes of Health Clinical Center (CC)
Pubblicazioni e link utili
Pubblicazioni generali
- Loupy A, Lefaucheur C, Vernerey D, Prugger C, Duong van Huyen JP, Mooney N, Suberbielle C, Fremeaux-Bacchi V, Mejean A, Desgrandchamps F, Anglicheau D, Nochy D, Charron D, Empana JP, Delahousse M, Legendre C, Glotz D, Hill GS, Zeevi A, Jouven X. Complement-binding anti-HLA antibodies and kidney-allograft survival. N Engl J Med. 2013 Sep 26;369(13):1215-26. doi: 10.1056/NEJMoa1302506.
- Chen G, Sequeira F, Tyan DB. Novel C1q assay reveals a clinically relevant subset of human leukocyte antigen antibodies independent of immunoglobulin G strength on single antigen beads. Hum Immunol. 2011 Oct;72(10):849-58. doi: 10.1016/j.humimm.2011.07.001. Epub 2011 Jul 18.
- Fontaine MJ, Kuo J, Chen G, Galel SA, Miller E, Sequeira F, Viele M, Goodnough LT, Tyan DB. Complement (C1q) fixing solid-phase screening for HLA antibodies increases the availability of compatible platelet components for refractory patients. Transfusion. 2011 Dec;51(12):2611-8. doi: 10.1111/j.1537-2995.2011.03194.x. Epub 2011 May 26.
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stimato)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 999916155
- 16-CC-N155
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .