Complement (C1q) binding aan HLA-antilichamen in een vaste fase immunoassay en klinisch effect op bloedplaatjestransfusie
Complement (C1q) binding aan HLA-antilichamen in een vaste-fase immunoassay en klinisch effect op bloedplaatjestransfusie
Background:
Platelets are blood cells that help blood clot. Some people have what is called thrombocytopenia. This means they have a low blood platelet count. They need platelet transfusions very often. Human leukocyte antigen (HLA) alloimmunization occurs for a lot of these people. They become refractory. This means their platelet levels no longer increase after transfusions. Researchers want to study a procedure that detects HLA antibodies. They want to test how well it predicts how a person will respond to a transfusion. They want to see if it does this better than the procedure that is usually used.
Objective:
To study the effect of C1q-binding of Class I HLA antibodies on platelet refractoriness in people who get platelet transfusions. To test if this method better predicts response to platelet transfusion than the IgG solid phase immunoassay method.
Eligibility:
People enrolled on protocols 11-C-0136, 08-H-0156, 03-C-0277, 01-C-0157, or 01-C-0129 who:
Agreed to have their specimens and data used for future research
Had Class I HLA antibodies detected by the IgG method
Had one or more platelet transfusions at NIH after the first positive HLA IgG antibody result
Design:
For each participant, researchers will look at a small portion of their archived plasma sample. The samples were left over from prior HLA antibody tests.
Participants samples will be analyzed. They will be tested to see if C1q-binding HLA antibodies are present. This will be done by solid phase immunoassay. Results will be compared with the past results of the IgG method.
Participants data will be stored in database that s protected by password.
...
Studie Overzicht
Toestand
Gedetailleerde beschrijving
Human leukocyte antigen (HLA) alloimmunization is common in patients undergoing frequent platelet transfusion, and is the most important cause of immune platelet refractoriness. Management strategies in HLA alloimmune platelet-refractory patients include transfusion with HLA-matched or crossmatched platelets; however, in broadly-sensitized patients, or in patients with uncommon HLA types, antigen-negative or epitope compatible donors may be difficult to find.
The Luminex immunoglobulin (Ig)G single-antigen-bead (SAB) solid phase immunoassay is now commonly used to detect HLA antibodies. However, an assay that specifically detects C1qbinding to HLA antibodies has been reported to identify a clinically relevant subset of HLA antibodies in solid organ transplantation; one group has studied the utility of this assay in platelet transfusion of HLA-alloimmunized platelet refractory patients. We intend to evaluate the ability of this C1-binding immunoassay to predict response to platelet transfusion in HLA alloimmune patients.
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
Maryland
-
Bethesda, Maryland, Verenigde Staten, 20892
- National Institutes of Health Clinical Center
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Beschrijving
-
INCLUSION CRITERIA:
- Class I HLA antibodies detected by the IgG solid phase immunoassay method
- Greater than or equal to 1 episode of platelet transfusion at NIH after the first positive HLA IgG antibody result
EXCLUSION CRITERIA:
1) Hyperproliferative thrombocytopenia
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Observatiemodellen: COHORT
- Tijdsperspectieven: RETROSPECTIVE
Cohorten en interventies
Groep / Cohort |
|---|
|
1
Previously selected HLA-alloimmunized platelet refractory, clinical, patients. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Corrected count increment after platelet transfusion
Tijdsspanne: Retrospective
|
Corrected Count Increment |
Retrospective
|
Medewerkers en onderzoekers
Onderzoekers
- Hoofdonderzoeker: Willy A Flegel, M.D., National Institutes of Health Clinical Center (CC)
Publicaties en nuttige links
Algemene publicaties
- Loupy A, Lefaucheur C, Vernerey D, Prugger C, Duong van Huyen JP, Mooney N, Suberbielle C, Fremeaux-Bacchi V, Mejean A, Desgrandchamps F, Anglicheau D, Nochy D, Charron D, Empana JP, Delahousse M, Legendre C, Glotz D, Hill GS, Zeevi A, Jouven X. Complement-binding anti-HLA antibodies and kidney-allograft survival. N Engl J Med. 2013 Sep 26;369(13):1215-26. doi: 10.1056/NEJMoa1302506.
- Chen G, Sequeira F, Tyan DB. Novel C1q assay reveals a clinically relevant subset of human leukocyte antigen antibodies independent of immunoglobulin G strength on single antigen beads. Hum Immunol. 2011 Oct;72(10):849-58. doi: 10.1016/j.humimm.2011.07.001. Epub 2011 Jul 18.
- Fontaine MJ, Kuo J, Chen G, Galel SA, Miller E, Sequeira F, Viele M, Goodnough LT, Tyan DB. Complement (C1q) fixing solid-phase screening for HLA antibodies increases the availability of compatible platelet components for refractory patients. Transfusion. 2011 Dec;51(12):2611-8. doi: 10.1111/j.1537-2995.2011.03194.x. Epub 2011 May 26.
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Geschat)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 999916155
- 16-CC-N155
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .