Image Fusion and Calcification Raising in Trans Aortic Valve Implantation (TAVI)
Value of Fusion of 3D Images With 2D Images, Associated With Calcification Raising During Trans Aortic Valve Implantation Procedures
Aortic stenosis is one of the most common cardiology diseases. Trans aortic valve implantation (TAVI) has been developed since 2002, first to treat rejected patients from conventional surgery, then to treat high surgical risk patients and nowadays probably intermediate surgical risk patient. TAVI related complications are still recurrent and the investigators are searching a way to decrease them.
One of them could be image fusion, since it may decrease radiation exposure and contrast agent use. It may also improve valve placement position leading to decreased complications.
40 prospective and consecutive patients will be included. Participants will be divided into two groups: the 20 first included will be control group, the 20 following patients will be the fusion group. For control group TAVI procedure will be the usual one, for fusion group the procedure will be the usual one with addition of computed tomography 3D images fusion with fluoroscopy 2D images.
Main evaluation criteria will be radiation exposure, measured by dose area product (DAP). Secondary evaluation criterion will be procedural as contrast agent volume used, procedure duration, subjective usefulness of image fusion or procedure failure evaluated immediately after procedure. The investigators will also evaluated procedure induced complications as de novo pacemaker implantation, de novo left bundle branch, vascular complication, major bleeding, acute kidney failure, significant aortic regurgitation. These complications occurrence will be evaluated after 1 month follow up, during the usual following consultation.
연구 개요
상태
상태
정황
정황
개입 / 치료
개입 / 치료
상세 설명
Aortic stenosis is one of the most common cardiology diseases. If untreated, symptomatic aortic stenosis rapidly leads to death. Most of the time, this disease affects old fragile people for whom conventional surgery is countered or very risky. That is why Trans aortic valve implantation has been developed since 2002, first to treat rejected patients from conventional surgery, then to treat high surgical risk patients and nowadays probably intermediate surgical risk patient. Indeed, thanks to prodigious technical and human progress, procedure induced complication have clearly decreased. But TAVI related complications are still recurrent and the investigators are searching a way to decrease them.
One of them could be image fusion, since it may decrease radiation exposure and contrast agent use correlated to acute kidney failure. It may also improve valve placement position, and the investigators know that many rhythmic (atrio-ventricular block) and valvular (significant aortic regurgitation) complications are partially due to placement mistakes. So the investigators hope that image fusion will decrease these complications.
The investigators will include 40 prospective and consecutive patients. Inclusion criterion will be all major patients admitted in Nantes CHU for transfemoral aortic valve replacement with SAPIEN® 3 valve. Exclusion criterion will be women of childbearing age without contraception, impossible written consent, judiciary protected people. After inclusion, patients will be divided into two groups: the 20 first included will be control group, the 20 following patients will be the fusion group. For control group TAVI procedure will be the usual one, for fusion group the procedure will be the usual one with addition of computed tomography 3D images fusion with fluoroscopy 2D images. The only difference during all patient medical care will be the addition of image fusion in fusion group. Before and after procedure, both groups will have the usual medical monitoring and the appropriated medical interventions to participants case.
Main evaluation criterion will be radiation exposure, measured by dose area product (DAP).
Secondary evaluation criterion will be procedural as:
- contrast agent volume used (mL),
- procedure duration (min),
- subjective usefulness of image fusion evaluated on a 0 to 3 scale
- procedure failure : death, more than one valve implantation, valve dysfunction (mean trans-valvular gradient > 20 mmHg or moderate to severe aortic regurgitation) These criterions will be evaluated immediately after procedure.
The investigators will also evaluated procedure induced complications as:
- de novo pacemaker implantation
- de novo left bundle branch
- non minor vascular complication on VARC-2 definition
- major bleeding (BARC 3 or 5)
- acute kidney failure (AKIN 2 or 3)
- significant aortic regurgitation ≥ 2/4 These complications occurrence will be evaluated after 1 month follow up, during the usual following consultation with echocardiography.
Then differences between will be tested with appropriated statistical methods.
연구 유형
연구 유형
단계
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
-
Nantes, 프랑스, 44093
- Nantes University Hospital
-
-
참여기준
자격 기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- All patients admitted in Nantes CHU for trans fermoral aortic valve replacement with SAPIEN 3® device
- Patient who accepted to participate to the study
Exclusion Criteria:
- Impossible written consent
- Judiciary protected people
- Minor
- Women of childbearing age without contraception
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 다른
- 할당: 무작위화되지 않음
- 중재 모델: 병렬 할당
- 마스킹: 없음(오픈 라벨)
팔의 수
무기와 개입
참가자 그룹 / 팔참가자 그룹 / 팔 |
개입 / 치료개입 / 치료 |
|---|---|
|
실험적: Group "Fusion"
Trans aortic valve replacement with usual procedure with the addition of computed tomography 3D images and calcification raising to the usual fluoroscopy images.
|
Addition of computed tomography 3D images and calcification raising to the usual fluoroscopy images.
|
|
간섭 없음: Group "Control"
Trans aortic valve replacement with usual procedure
|
연구는 무엇을 측정합니까?
주요 결과 측정
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Radiation exposure
기간: Immediately post procedure
|
Dose area product (cGy/cm2)
|
Immediately post procedure
|
2차 결과 측정
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Contrast product
기간: Immediately post procedure
|
Contrast volume (mL) used during procedure
|
Immediately post procedure
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
연구 시작
기본 완료 (실제)
기본 완료
연구 완료 (실제)
연구 완료
연구 등록 날짜
최초 제출
최초 제출
QC 기준을 충족하는 최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
처음 게시됨
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
마지막 업데이트 게시됨
QC 기준을 충족하는 마지막 업데이트 제출
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
기타 연구 ID 번호
- RC17_0114
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .
Image Fusion에 대한 임상 시험
-
NCT05237908모집하지 않고 적극적으로추간판 탈출증 | 척추전방전위증 | 디스크 질환 퇴행성
-
NCT05712850초대로 등록골반 골절 | 천장관절염 | 천장 관절 기능 장애 | 의원성 상해 | Ostitis Condensans Ilii