Image Fusion and Calcification Raising in Trans Aortic Valve Implantation (TAVI)
Value of Fusion of 3D Images With 2D Images, Associated With Calcification Raising During Trans Aortic Valve Implantation Procedures
Aortic stenosis is one of the most common cardiology diseases. Trans aortic valve implantation (TAVI) has been developed since 2002, first to treat rejected patients from conventional surgery, then to treat high surgical risk patients and nowadays probably intermediate surgical risk patient. TAVI related complications are still recurrent and the investigators are searching a way to decrease them.
One of them could be image fusion, since it may decrease radiation exposure and contrast agent use. It may also improve valve placement position leading to decreased complications.
40 prospective and consecutive patients will be included. Participants will be divided into two groups: the 20 first included will be control group, the 20 following patients will be the fusion group. For control group TAVI procedure will be the usual one, for fusion group the procedure will be the usual one with addition of computed tomography 3D images fusion with fluoroscopy 2D images.
Main evaluation criteria will be radiation exposure, measured by dose area product (DAP). Secondary evaluation criterion will be procedural as contrast agent volume used, procedure duration, subjective usefulness of image fusion or procedure failure evaluated immediately after procedure. The investigators will also evaluated procedure induced complications as de novo pacemaker implantation, de novo left bundle branch, vascular complication, major bleeding, acute kidney failure, significant aortic regurgitation. These complications occurrence will be evaluated after 1 month follow up, during the usual following consultation.
Studieoversikt
Status
Status
Forhold
Forhold
Intervensjon / Behandling
Intervensjon / Behandling
Detaljert beskrivelse
Aortic stenosis is one of the most common cardiology diseases. If untreated, symptomatic aortic stenosis rapidly leads to death. Most of the time, this disease affects old fragile people for whom conventional surgery is countered or very risky. That is why Trans aortic valve implantation has been developed since 2002, first to treat rejected patients from conventional surgery, then to treat high surgical risk patients and nowadays probably intermediate surgical risk patient. Indeed, thanks to prodigious technical and human progress, procedure induced complication have clearly decreased. But TAVI related complications are still recurrent and the investigators are searching a way to decrease them.
One of them could be image fusion, since it may decrease radiation exposure and contrast agent use correlated to acute kidney failure. It may also improve valve placement position, and the investigators know that many rhythmic (atrio-ventricular block) and valvular (significant aortic regurgitation) complications are partially due to placement mistakes. So the investigators hope that image fusion will decrease these complications.
The investigators will include 40 prospective and consecutive patients. Inclusion criterion will be all major patients admitted in Nantes CHU for transfemoral aortic valve replacement with SAPIEN® 3 valve. Exclusion criterion will be women of childbearing age without contraception, impossible written consent, judiciary protected people. After inclusion, patients will be divided into two groups: the 20 first included will be control group, the 20 following patients will be the fusion group. For control group TAVI procedure will be the usual one, for fusion group the procedure will be the usual one with addition of computed tomography 3D images fusion with fluoroscopy 2D images. The only difference during all patient medical care will be the addition of image fusion in fusion group. Before and after procedure, both groups will have the usual medical monitoring and the appropriated medical interventions to participants case.
Main evaluation criterion will be radiation exposure, measured by dose area product (DAP).
Secondary evaluation criterion will be procedural as:
- contrast agent volume used (mL),
- procedure duration (min),
- subjective usefulness of image fusion evaluated on a 0 to 3 scale
- procedure failure : death, more than one valve implantation, valve dysfunction (mean trans-valvular gradient > 20 mmHg or moderate to severe aortic regurgitation) These criterions will be evaluated immediately after procedure.
The investigators will also evaluated procedure induced complications as:
- de novo pacemaker implantation
- de novo left bundle branch
- non minor vascular complication on VARC-2 definition
- major bleeding (BARC 3 or 5)
- acute kidney failure (AKIN 2 or 3)
- significant aortic regurgitation ≥ 2/4 These complications occurrence will be evaluated after 1 month follow up, during the usual following consultation with echocardiography.
Then differences between will be tested with appropriated statistical methods.
Studietype
Studietype
Fase
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
-
Nantes, Frankrike, 44093
- Nantes University Hospital
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- All patients admitted in Nantes CHU for trans fermoral aortic valve replacement with SAPIEN 3® device
- Patient who accepted to participate to the study
Exclusion Criteria:
- Impossible written consent
- Judiciary protected people
- Minor
- Women of childbearing age without contraception
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Annen
- Tildeling: Ikke-randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Ingen (Open Label)
Antall våpen
Våpen og intervensjoner
Deltakergruppe / ArmDeltakergruppe / Arm |
Intervensjon / BehandlingIntervensjon / Behandling |
|---|---|
|
Eksperimentell: Group "Fusion"
Trans aortic valve replacement with usual procedure with the addition of computed tomography 3D images and calcification raising to the usual fluoroscopy images.
|
Addition of computed tomography 3D images and calcification raising to the usual fluoroscopy images.
|
|
Ingen inngripen: Group "Control"
Trans aortic valve replacement with usual procedure
|
Hva måler studien?
Primære resultatmål
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Radiation exposure
Tidsramme: Immediately post procedure
|
Dose area product (cGy/cm2)
|
Immediately post procedure
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Contrast product
Tidsramme: Immediately post procedure
|
Contrast volume (mL) used during procedure
|
Immediately post procedure
|
Samarbeidspartnere og etterforskere
Sponsor
Sponsor
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Studiestart
Primær fullføring (Faktiske)
Primær fullføring
Studiet fullført (Faktiske)
Studiet fullført
Datoer for studieregistrering
Først innsendt
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Først lagt ut
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Sist oppdatering lagt ut
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
Andre studie-ID-numre
- RC17_0114
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .
Kliniske studier på Symptomatisk aortastenose
-
NCT05692063RekrutteringAnomalous aortic origin of the coronary artery (AAOCA)
-
NCT03381222FullførtAscending Aortic Ateromatous Plaque
-
NCT06084000RekrutteringDe Novo Stenosis | Medikamentbelagt ballong | Medikamentavgivende stent
-
NCT06247982Aktiv, ikke rekrutterende
-
NCT01129921FullførtLumbal Spine Stenosis Central Canal
-
NCT06013007FullførtAkutt koronarsyndrom | De Novo Stenosis
-
NCT04561739Aktiv, ikke rekrutterendeKoronararteriesykdom | De Novo Stenosis
-
NCT07022587RekrutteringKoronararteriesykdom | De Novo Stenosis
-
NCT05209412Aktiv, ikke rekrutterendeKoronararteriesykdom | Perkutan koronar intervensjon | De Novo Stenosis
-
NCT05134545FullførtPerifer arteriesykdom | De Novo Stenosis
Kliniske studier på Image Fusion
-
NCT01921530UkjentSpinal stenose | Degenerativ spondylolistese
-
NCT05691062Påmelding etter invitasjonLumbal spondylolistese | Spine Fusion | Lumbal stenose
-
NCT03413137Ukjent
-
NCT06876311Aktiv, ikke rekrutterendeDegenerativ cervical disc sykdom | Degenerative lumbale sykdommer
-
NCT00254852AvsluttetDegenerativ skivesykdom | Spondylolistese | Stenose
-
NCT03315377Aktiv, ikke rekrutterende
-
NCT02564705Fullført
-
NCT03187171TilbaketrukketKirurgi | Degenerativ skivesykdom | Cervical Spine Disc Sykdom | Fusjon av ryggraden