Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Self-pressurised Air-Q With Blocker Versus Baska Mask in Low Risk Female Patients Undergoing Ambulatory Surgery.

9 januari 2019 bijgewerkt door: Abeer Ahmed, MD, Cairo University

A Randomized Comparison of Self-pressurized Air-Q With Blocker With Baska Mask Supraglottic Airway in Low Risk Female Patients Undergoing Ambulatory Surgery.

Supraglottic airway devices (SGAs) are very commonly used during anesthesia but structural vulnerability to airway morbidity and issues about cuff pressure still concern anesthesiologists. There have been controversial results regarding optimal intra-cuff pressure in various types of cuffed supraglottic airways. When the supraglottic cuff pressure is more than the mucosal perfusion pressure, it is likely to either cause postoperative pharyngo-laryngeal symptoms like sore throat (dysphagia, dysphonia) or cause local mucosal trauma and nerve injuries. Supraglottic airway devices with non-inflatable cuff have advantages in omitting the cuff pressure monitoring and reducing potential pharyngo-laryngeal complications.

Self-pressurizing Air Q blocker is the latest version. It has a drain tube through which a suction tube is passed. There is an inflatable cuff at the end of this tube. On inflation, the cuff seals the esophageal opening into the stomach, preventing any regurgitation of stomach contents. Instead of the pilot balloon and inflating cuff, the air-Q SP with blocker has a communication orifice at the junction of the peri-glotic cuff and the airway tube. This communication between two spaces enables the cuff to dynamically regulate intra-cuff pressure depending on airway pressure. This distinguishing feature of the air-Q SP may result in reduced risk for airway morbidities related to cuff hyperinflation.

The Baska mask is a novel supraglottic airway device with a non-inflatable cuff, an oesophageal drainage inlet and side channels to facilitate aspiration of gastric contents, and an integrated bite-block. It was revealed that the baska mask is relatively easy to insert, provided a high-quality seal with the glotic aperture and the incidence of throat discomfort appeared low.

To our knowledge, and after searching in previous literature, no previous studies have compared the Air-Q SP with blocker with Baska mask; another supraglottic airway devices with non-inflatable cuff.

Studie Overzicht

Studietype

Ingrijpend

Inschrijving (Verwacht)

62

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Locaties

      • Cairo, Egypte, 00225
        • Werving
        • Kasr Alainy Faculty of Medicine - Cairo university
        • Contact:
          • Abeer Ahmed, Assistant Professor

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar tot 50 jaar (Volwassen)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Vrouw

Beschrijving

Inclusion Criteria:

  • Female patients between the age group of 18 and 50 years,
  • ASA class I and II,
  • undergoing elective surgeries,
  • with Ganzouri airway score less than 4

Exclusion Criteria:

  • ASA III - V patients.
  • Airway score ≥ 4 according to El-Ganzouri Airway Scoring System.
  • Patients with respiratory or pharyngeal pathology.
  • Patients allergic to any drugs in the protocol.
  • Obese patients with body mass index ≥ 40.
  • Patients known to have risk of gastric aspiration, gastro-esophageal reflux disease, hiatus hernia or previous upper gastrointestinal tract surgery.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Ander
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Enkel

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: SP group
comparing the airway seal pressure 10 min after insertion of each devices .
Andere namen:
  • airway management under general anesthesia
Actieve vergelijker: Baska group
comparing the airway seal pressure 10 min after insertion of each devices .
Andere namen:
  • airway management under general anesthesia

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Tijdsspanne
airway seal pressure 10 minutes after insertion
Tijdsspanne: 10 minutes after the device insertion.
10 minutes after the device insertion.

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Verwacht)

1 februari 2019

Primaire voltooiing (Verwacht)

1 mei 2019

Studie voltooiing (Verwacht)

1 juni 2019

Studieregistratiedata

Eerst ingediend

7 januari 2019

Eerst ingediend dat voldeed aan de QC-criteria

9 januari 2019

Eerst geplaatst (Werkelijk)

10 januari 2019

Updates van studierecords

Laatste update geplaatst (Werkelijk)

10 januari 2019

Laatste update ingediend die voldeed aan QC-criteria

9 januari 2019

Laatst geverifieerd

1 januari 2019

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • N-24- 2018

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

product vervaardigd in en geëxporteerd uit de V.S.

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Klinische onderzoeken op Supraglottische luchtwegapparaten

3
Abonneren