- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT06102499
Porównanie pulsoksymetrii (SpO2) z różnymi pulsoksymetrami i saturacją tętniczą (SaO2): badanie Oxygap2 (Oxygap 2)
The oximeter is used to monitor intensive care patients undergoing oxygen therapy. It indicates pulsed oxygen saturation (SpO2), a reflection of arterial oxygen saturation (SaO2) which enables detection of hypoxemia and hyperoxia, both deleterious state. Current SpO2 recommendations aim to reduce both risk of hypoxemia and hyperoxia. SpO2 is considered the 5th vital sign.
Current recommendations for SpO2 targets do not consider the variability of oximeters used in clinical practice. This variability and lack of specification represent an obstacle to an optimal practice of oxygen therapy.
Thus, this study aims to compare the SpO2 values of different oximeters (General Electric-GE, Medtronic, Masimo and Nonin) used in clinical practice with the SaO2 reference value obtained by an arterial gas in order to specify the precision and the systematic biases of the oximeters studied. This data will also make it possible to refine the recommendations concerning optimal oxygenation
Przegląd badań
Status
Interwencja / Leczenie
Typ studiów
Zapisy (Szacowany)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Les Abymes, Gwadelupa, 97139
- Jeszcze nie rekrutacja
- CHU de la Guadeloupe
-
Kontakt:
- Frederic Martino
- Numer telefonu: : +590 590 89 11 32
- E-mail: frederic.martino@chu-guadeloupe.fr
-
-
-
-
Quebec
-
Montreal, Quebec, Kanada, H3T 1C5
- Rekrutacyjny
- CHU Ste-Justine
-
Kontakt:
- Michael Sauthier
- Numer telefonu: 514 345-4931
- E-mail: Michael.Sauthier.med@ssss.gouv.qc.ca
-
Montreal, Quebec, Kanada, H2X0A9
- Zakończony
- CHUM
-
Québec, Quebec, Kanada, G1V 4G5
- Rekrutacyjny
- Institut Universitaire de Cardiologie et de Pneumologie de Québec
-
Kontakt:
- Francois Lellouche
- Numer telefonu: 3572 1-418-656-8711
- E-mail: francois.lellouche@criucpq.ulaval.ca
-
-
-
-
-
Sousse, Tunezja, 4000
- Jeszcze nie rekrutacja
- Hôpital Universitaire Farhat Hached,
-
Kontakt:
- Mohamed Boussarsar
- Numer telefonu: +216 73 102 500
- E-mail: hamadi.boussarsar@gmail.com
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
All patient in ICU with arterial catheter already installed will be consider
Opis
Adult population
Inclusion Criteria:
- ≥ 18 years old (adult population) -
- Patients admitted to the Intensive Care Unit
- Artery catheter already installed
Pediatric population
- Below 18 years old
- Patients admitted to the Intensive Care Unit
- Artery catheter already installed
Exclusion Criteria:
- No or poor signal with the usual pulse oximeter/based on clinician judgment
- High dose of vasopressors or inotropes (epinephrine or norepinephrine ˃ 1mcg/kg/min), shock state (lactates above 3 mmoles/L)
- Pigmented nails or nail polish
- Methemoglobinemia history
- Hemoglobin below 80 g/L
- Patient in isolation (multi-resistant bacteria, C-Difficile, SARS-COV-2…)
- Prone position, Extra Corporel Membrane Oxygenator
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Modele obserwacyjne: COHORT
- Perspektywy czasowe: PROSPECTIVE
Kohorty i interwencje
Grupa / Kohorta |
Interwencja / Leczenie |
|---|---|
|
Pediatric population
Pediatric population < 18 years old (estimated 100 patients) |
Several pulse oximeter will be place on patient find few minutes before arterial blood gases. During an arterial blood sample, all SpO2 will be recorded |
|
Adult population
Adult population >or= 18 years old (estimated 150 patients) |
Several pulse oximeter will be place on patient find few minutes before arterial blood gases. During an arterial blood sample, all SpO2 will be recorded |
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Difference between GE oximeter SpO2 value and the SaO2 value on arterial blood gases
Ramy czasowe: During procedure (arterial blood gas sample collection)
|
Difference between GE oximeter SpO2 and the SaO2 value |
During procedure (arterial blood gas sample collection)
|
|
Difference between Nellcor oximeter SpO2 value and the SaO2 value on arterial blood gases
Ramy czasowe: During procedure (arterial blood gassample collection)
|
Difference between Nellcor oximeter SpO2 and the SaO2 value |
During procedure (arterial blood gassample collection)
|
|
Difference between Masimo oximeter SpO2 value and the SaO2 value on arterial blood gases
Ramy czasowe: During procedure (arterial blood gas sample collection)
|
Difference between Masimo oximeter SpO2 and the SaO2 value |
During procedure (arterial blood gas sample collection)
|
|
Difference between Nonin oximeter SpO2 value and the SaO2 value on arterial blood gases
Ramy czasowe: During procedure (arterial blood gas sample collection)
|
Difference between Nonin oximeter SpO2 and the SaO2 value |
During procedure (arterial blood gas sample collection)
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Overestimation and underestimation of SaO2
Ramy czasowe: During procedure (arterial blood gas sample collection)
|
Percent of pairs with overestimation and underestimation of SaO2 for each oximeter. |
During procedure (arterial blood gas sample collection)
|
|
Hypoxemia detection
Ramy czasowe: During procedure (arterial blood gas sample collection)
|
Ability to detect hypoxemia (SpO2 below 90% and PaO2 < 60 mmHg) |
During procedure (arterial blood gas sample collection)
|
Inne miary wyników
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Hyperoxemia detection
Ramy czasowe: During procedure (arterial blood gas sample collection)
|
Ability to detect hyperoxemia (SpO2 above 95% and PaO2 > 100 mmHg) |
During procedure (arterial blood gas sample collection)
|
|
Gaps between the different oximeters
Ramy czasowe: During procedure (arterial blood gas sample collection)
|
Average of the SpO2 value gaps between the different oximeters tested |
During procedure (arterial blood gas sample collection)
|
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 22373
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .