- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT05405673
Precisão diagnóstica de um painel de marcadores genéticos bacterianos (M3) para neoplasia avançada colorretal (M3-PRO)
Um estudo transversal prospectivo para avaliar a precisão diagnóstica de um painel de marcadores genéticos bacterianos (M3) para neoplasia avançada colorretal
The investigators aim to evaluate and compare the diagnostic accuracy of FIT and the novel panel of bacterial gene markers (Fn, m3, Ch and Bc) collectively named as M3, in detecting colorectal advanced neoplasia.
Visão geral do estudo
Status
Intervenção / Tratamento
Descrição detalhada
Colorectal cancer (CRC) is the one of the most common cancers in Hong Kong with more than 5,500 new cases annually. There is prevailing evidence of increasing trend of young onset CRC globally. Early detection and resection of pre-malignant colorectal neoplasia has shown to reduce CRC-related mortality.
Non-invasive stool tests including guaiac-based faecal occult blood tests (gFOBT) and faecal immunochemical tests (FIT) are the cornerstones of population-based CRC screening programmes. The major limitation of this widely used strategy is its unsatisfactory sensitivities for CRC (79%) and advanced adenomas (AA; 40%). The sensitivity for non-advanced adenomas is even lower than 10%. A large proportion of advanced and non-advanced adenomas will be missed by FIT alone. Therefore, identification of alternative non-invasive test with better sensitivity to detect colorectal neoplasia is warranted.
Multitarget stool DNA test and faecal microbial DNA markers appear to be promising options for CRC screening. Several bacterial gene markers have been identified by metagenome sequencing and reported to be associated with CRC, including Fusobacterium nucleatum (Fn), Clostridium hathewayi (Ch) and Bacteroides clarus (Bc). However, these molecular markers had low accuracy in distinguishing adenomas from normal tissue. Recently, a new Lachnoclostridium gene marker (labelled as 'm3') has been shown to have high diagnostic yield for the detection of colorectal adenomas. In a case-control study of 1012 subjects, a linear increasing trend of m3 level was observed from fecal samples of healthy subjects to those with adenomas and cancers. The overall sensitivity of m3 was significantly higher than FIT in detecting all adenomas (48% vs 9.3%), AA (50.8% vs 16.1%) and non-advanced adenomas (44.2% vs 0%). The diagnostic accuracy of m3 could be further enhanced by combining with a panel of fecal microbial markers composing of Fusobacterium nucleatum (Fn), Bacteroides clarus (Bc), Clostridium hathewayi (Ch) for CRC (82.3%) and adenomas (64.2%). We hypothesized that the combination of these 4 bacterial gene markers (known as M3) is more sensitive than FIT in detecting colorectal advanced neoplasia.
Tipo de estudo
Inscrição (Estimado)
Contactos e Locais
Locais de estudo
-
-
-
Hong Kong, Hong Kong
- Prince of Wales Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Subjects with average risk of colorectal neoplsia requring screening/surveillance colonoscopy
Descrição
Inclusion Criteria:
- They require elective colonoscopy for colorectal cancer screening or polyp surveillance, or investigation of symptoms (e.g. anemia, change of bowel habit, abdominal pain);
- Aged ≥18 years old;
- Written informed consent obtained.
Exclusion Criteria:
- Contraindications to colonoscopy (e.g. perforation, intestinal obstruction, unstable cardiopulmonary status);
- Contraindication to polyp resection (e.g. active gastrointestinal bleeding, uninterrupted anticoagulation or dual antiplatelets);
- Known colorectal cancer or adenoma for staged procedure;
- Previous colonic resection;
- Personal history of colorectal cancer;
- Personal history of polyposis syndrome;
- Personal history of inflammatory bowel disease;
- Known pregnancy or lactation;
- Advanced comorbid conditions (defined as American Society of Anesthesiologists grade 4 or above);
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Modelos de observação: CASE_ONLY
- Perspectivas de Tempo: CROSS_SECTIONAL
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
Colorectal neoplasia screening/surveillance cohort
Subjects with average risk of colorectal neoplasias requiring screening/surveillance colonoscopy |
A kind of stool test
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Sensitivity of bacterial gene markers panel (M3)
Prazo: 1 month
|
The proportion of subjects with true positive results of M3 among those with one of more advanced neoplasia detected in the index colonoscopy. |
1 month
|
|
Sensitivity of FIT/FOBT
Prazo: 1 month
|
The proportion of subjects with true positive results of FIT among those with one of more advanced neoplasia detected in the index colonoscopy. |
1 month
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Sensitivity of M3 for early-stage (stage 1) or invasive (stage 2-4) colorectal cancers
Prazo: 1 month
|
The proportion of subjects with true positive results of M3 among those with early-stage (stage 1) or invasive (stage 2-4) colorectal cancers detected in the index colonoscopy. |
1 month
|
|
Sensitivity of FIT/FOBT for early-stage (stage 1) or invasive (stage 2-4) colorectal cancers
Prazo: 1 month
|
The proportion of subjects with true positive results of FIT among those with early-stage (stage 1) or invasive (stage 2-4) colorectal cancers detected in the index colonoscopy. |
1 month
|
|
Sensitivity of FIT/FOBT for advanced adenomas
Prazo: 1 month
|
The proportion of subjects with true positive results of FIT among those with one or more advanced adenomas detected in the index colonoscopy. |
1 month
|
|
Sensitivity of M3 for advanced adenomas
Prazo: 1 month
|
The proportion of subjects with true positive results of M3 among those with one or more advanced adenomas detected in the index colonoscopy. |
1 month
|
|
Sensitivity of FIT/FOBT for all adenomas
Prazo: 1 month
|
The proportion of subjects with true positive results of FIT among those with all advanced adenomas detected in the index colonoscopy. |
1 month
|
|
Sensitivity of M3 for all adenomas
Prazo: 1 month
|
The proportion of subjects with true positive results of M3 among those with all advanced adenomas detected in the index colonoscopy. |
1 month
|
|
Sensitivity of FIT/FOBT for sessile serrated lesions (SSL)
Prazo: 1 month
|
The proportion of subjects with true positive results of FIT among those with SSLs detected in the index colonoscopy. |
1 month
|
|
Sensitivity of M3 for sessile serrated lesions (SSL)
Prazo: 1 month
|
The proportion of subjects with true positive results of M3 among those with SSLs detected in the index colonoscopy. |
1 month
|
|
Specificity
Prazo: 1 month
|
The proportion of true negative results of M3/FOBT/FIT among those with no adenoma detected in colonoscopy |
1 month
|
|
Positive predictive value (PPV)
Prazo: 1 month
|
The ratio of subjects truly diagnosed as positive to all those who had positive test results |
1 month
|
|
Negative predictive value (NPV)
Prazo: 1 month
|
The ratio of subjects truly diagnosed as negative to all those who had negative test results |
1 month
|
|
Overall diagnostic accuracy
Prazo: 1 month
|
The proportion of correctly classified subjects among all subjects |
1 month
|
|
Microbiota changes in subjects with adenomas or normal findings after polypectomy
Prazo: 1 month
|
Microbiota change measured by qPCR or metagenomic sequencing |
1 month
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 2022.170
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .