Validation of a Connected Patch, an Alternative to Conventional Monitoring
Обзор исследования
Подробное описание
When patients operated on outside intensive care or intensive care units are hospitalized, vital signs are collected intermittently by various conventional devices. During the follow-up period of these patients, it is possible that abnormal vital signs that may identify clinical deterioration may appear a few minutes to a few hours before a serious adverse event (infection etc.) occurs. These signals often go unnoticed due to infrequent monitoring.
The establishment of teams to ensure a rapid response would improve the safety of hospitalized patients for whom the detection of abnormal vital signs predictive of clinical deterioration would generate an alarm. This system is based on the identification of patients at risk and the rapid intervention of the team.
One of the crucial issues is therefore the speed of the alarm and its reliability.
The evolution of electronic technology offers the possibility of using inexpensive portable devices (connected patches) that can provide information on vital signs in real time. Vital signs collected by these devices could be analyzed to predict clinical deterioration prior to hospital staff visits, especially at night and on weekends when staffing levels are generally lower.
The connected patch used in this research is the Scaléo Médical company's device "myAngel VitalSigns". The long-term objective would be to be able to use this connected patch in surgical departments to detect early a complication, particularly of a cardiovascular or respiratory nature, and therefore to treat it without wasting time. However, it has not been validated in a hospital setting; that is the purpose of the project.
The objective of this research is therefore to validate Scaléo Médical's connected patch in different locations: post-interventional surveillance room that approaches a conventional hospital room, operating room where artifacts are numerous.
Тип исследования
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
-
Suresnes, Франция, 92150
- Hôpital Foch
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- patient over 18 and under 85 years of age
- patient requiring general anesthesia for extra-thoracic surgery
- the patient's position during the operation is in supine position only
- patient affiliated to or benefiting from social security, excluding State Medical Assistance
- patient with written consent
Exclusion Criteria:
- pregnant or breastfeeding patients
- patients known to have severe skin reactions to adhésives
- patient whose surgical procedure prevents the patch from being placed (intervention on the thorax)
- patients deprived of their liberty or under guardianship
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Другой
- Распределение: Н/Д
- Интервенционная модель: Одногрупповое задание
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
---|---|
Экспериментальный: Проверка подключенного патча
|
Использование подключенного пластыря для измерения артериального давления, частоты сердечных сокращений, частоты дыхания, насыщения артериальной крови кислородом и температуры.
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
---|---|---|
Concordance of blood pressure value measured by 2 different devices after surgery
Временное ограничение: 36 hours maximum after the surgery
|
Comparison between blood pressure measured by conventional medical monitoring device and by connected patch
|
36 hours maximum after the surgery
|
Concordance of heart rate value measured by 2 different devices after surgery
Временное ограничение: 36 hours maximum after the surgery
|
Comparison between heart rate measured by conventional medical monitoring device and by connected patch
|
36 hours maximum after the surgery
|
Concordance of respiratory rate value measured by 2 different devices after surgery
Временное ограничение: 36 hours maximum after the surgery
|
Comparison between respiratory rate measured by conventional medical monitoring device and by connected patch
|
36 hours maximum after the surgery
|
Concordance of arterial oxygen saturation value measured by 2 different devices after surgery
Временное ограничение: 36 hours maximum after the surgery
|
Comparison between arterial oxygen saturation measured by conventional medical monitoring device and by connected patch
|
36 hours maximum after the surgery
|
Concordance of temperature value measured by 2 different devices after surgery
Временное ограничение: 36 hours maximum after the surgery
|
Comparison between temperature measured by conventional medical monitoring device and by connected patch
|
36 hours maximum after the surgery
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
---|---|---|
Concordance of blood pressure value measured by 2 different devices during surgery
Временное ограничение: During surgery
|
Comparison between blood pressure measured by conventional medical monitoring device and by connected patch
|
During surgery
|
Concordance of heart rate value measured by 2 different devices during surgery
Временное ограничение: During surgery
|
Comparison between heart rate measured by conventional medical monitoring device and by connected patch
|
During surgery
|
Concordance of respiratory rate value measured by 2 different devices during surgery
Временное ограничение: During surgery
|
Comparison between respiratory rate measured by conventional medical monitoring device and by connected patch
|
During surgery
|
Concordance of arterial oxygen saturation value measured by 2 different devices during surgery
Временное ограничение: During surgery
|
Comparison between arterial oxygen saturation measured by conventional medical monitoring device and by connected patch
|
During surgery
|
Concordance of temperature value measured by 2 different devices during surgery
Временное ограничение: During surgery
|
Comparison between temperature value measured by conventional medical monitoring device and by connected patch
|
During surgery
|
Blood pressure artifact
Временное ограничение: From surgery to 36 hours maximum after the surgery
|
Value of blood pressure will be considered as artifact if systolic blood pressure value < 80 or > 200 and diastolic blood pressure > 110
|
From surgery to 36 hours maximum after the surgery
|
Heart rate artifact
Временное ограничение: From surgery to 36 hours maximum after the surgery
|
Value of heart rate will be considered as artifact if value < 40 or > 140
|
From surgery to 36 hours maximum after the surgery
|
Respiratory rate artifact
Временное ограничение: From surgery to 36 hours maximum after the surgery
|
Value of respiratory rate will be considered as artifact if value < 8 or > 36
|
From surgery to 36 hours maximum after the surgery
|
Arterial oxygen saturation artifact
Временное ограничение: From surgery to 36 hours maximum after the surgery
|
Value of arterial oxygen saturation will be considered as artifact if value < 85 %
|
From surgery to 36 hours maximum after the surgery
|
Acceptability of connected patch: numerical scale
Временное ограничение: During the surgery and through study completion
|
Evaluation of connected patch with a simple numerical scale between 0 and 10: 0 representing a very poor tolerance of the device and leading to premature interruption of the collection and 10 a perfect tolerance allowing the patch to be maintained for several consecutive days
|
During the surgery and through study completion
|
Соавторы и исследователи
Спонсор
Следователи
- Главный следователь: Morgan Le Guen, Hôpital Foch
Даты записи исследования
Изучение основных дат
Начало исследования (Ожидаемый)
Первичное завершение (Ожидаемый)
Завершение исследования (Ожидаемый)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Другие идентификационные номера исследования
- 2017055F
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
продукт, произведенный в США и экспортированный из США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .
Клинические исследования Анестезия
-
Ohio State UniversityBaxter Healthcare CorporationЗавершенныйСевофлуран | Цистоскопы | Baxter Anesthesia Торговая марка DesfluraneСоединенные Штаты
Клинические исследования Проверка патча
-
Yonsei UniversityЕще не набираютФибрилляция/трепетание предсердий у пациентов с высоким риском инсультаКорея, Республика
-
Population Health Research InstituteHeart and Stroke Foundation of Canada; Canadian Cardiovascular SocietyЗавершенныйСердечная недостаточность | Мерцательная аритмияКанада
-
Chang Gung Memorial HospitalNational Yang Ming UniversityНеизвестныйАнализ сна-бодрствования
-
University of Maryland, BaltimoreРекрутингМерцательная аритмия Новое началоСоединенные Штаты
-
Element Science, Inc.Завершенный
-
LifeWatch Services, Inc.ЗавершенныйАвтоматическое измерение показателей жизнедеятельностиСоединенные Штаты
-
LeMaitre VascularРекрутингСердечные заболеванияКитай
-
Universitaire Ziekenhuizen KU LeuvenBytefliesАктивный, не рекрутирующий
-
Element Science, Inc.Запись по приглашениюВнезапная остановка сердцаЧехия
-
St. Justine's HospitalЕще не набирают