Immediate Versus Delayed Initiation of Intrauterine System (JANESS)
Immediate Versus Delayed Initiation of the 13.5 mg Levonorgestrel-releasing Intrauterine System Following Surgical Termination of Pregnancy
Contraception for teenagers and young adults presents a huge challenge for the clinician as more than half of all unintended pregnancies occur as a result of inconsistent or discontinued use of contraceptives . Possible solution is promoting the use of long acting reversible contraception, (LARC) among them the intrauterine device (IUD). IUD provide safe, highly effective, long-term contraception. Immediate IUD insertion after the termination of pregnancy (TOP) is a very convenient way to provide contraception as it is an opportune moment to carry out this short, easy, and safe procedure.
Janess is a T-shaped intrauterine delivery system that was introduced lately, which slowly releases a small amount (13.5 mg) of levonorgestrel after its installation inside the womb and provides contraception for up to three years.
The aim of this study to compare insertion of 13.5 mg levonorgestrel-releasing intrauterine system after surgical abortion immediately versus delayed insertion (at menstruation)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
The rate of repeat induced abortion varies from 30% to 38% in northern Europe. Young women, parous women and those with a history of abortion were found to be the main risk factors associated with recurrent termination of pregnancy. Young women may lack knowledge or access to conventional methods of preventing pregnancy, as they may be too embarrassed or frightened to seek such information. Contraception for teenagers and young adults presents a huge challenge for the clinician as more than half of all unintended pregnancies occur as a result of inconsistent or discontinued use of contraceptives . Possible solution is promoting the use of long acting reversible contraception, (LARC) among them the intrauterine device (IUD), that was found well suited even for adolescents. Because IUDs do not require active use once they have been inserted, and have a very low failure rate, their increased use has the potential to substantially reduce unintended pregnancies. IUD provide safe, highly effective, long-term contraception, but they are underused.
Immediate initiation of any contraceptive method after an abortion has been linked to a reduced risk of repeat abortion. Immediate IUD insertion after the termination of pregnancy (TOP) is a very convenient way to provide contraception as it is an opportune moment to carry out this short, easy, and safe procedure. As the cervix is dilated, insertion is virtually painless. Following insertion, the woman is protected immediately, before ovulation returns, usually within 7-10 days after first-trimester abortion.
Lately, a new intrauterine device directed for young women was introduced. It is a T-shaped intrauterine delivery system which slowly releases a small amount (13.5 mg) of levonorgestrel after its installation inside the womb. The system is intended for contraception for a period of up to 3 years. It works by reducing the monthly growth of the lining of the womb and thickening of the cervical mucosal layer.
To the best of the investigator's knowledge this is the first study to compare insertion of 13.5 mg levonorgestrel-releasing intrauterine system after surgical abortion immediately versus delayed insertion (at menstruation) .
Study Type
Study Type
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Aya Mohr Sasson, M.D
- Phone Number: 0523692906
- Email: mohraya@gmail.com
Study Locations
-
-
-
Ramat Gan, Israel
- Sheba Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Women that are about to go through surgical termination of first trimester pregnancy
- Age ≥ 18 years
- Nulliparous
Exclusion Criteria:
- structural uterine abnormality
- submucosal fibroids
- suspected uterine or cervical neoplasia
- acute pelvic inflammatory disease
- acute liver disease or previous breast cancer
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Prevention
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Immediate insertion
The intrauterine system will be inserted immediately after surgical termination of pregnancy, before awakening from anesthesia
|
13.5 mg levonorgestrel-releasing intrauterine system
Other Names:
|
|
Experimental: Delayed insertion
The intrauterine system will be inserted on the first menstruation after termination of pregnancy.
Women allocated to this arm will be asked to contact the study coordinator in order to visit the hospital on the proper timing for IUD insertion.
|
13.5 mg levonorgestrel-releasing intrauterine system
Other Names:
|
|
Other: Control
Women who refuse to actively participate in the intervention groups will be offered consultation on other options for contraception during gynecological clinic visit after fist menstruation from termination of pregnancy.
|
Alternative contraception including contraception pills, hormonal patches, hormonal vaginal , condomsring,
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Continuation rate after one year from insertion
Time Frame: estimated time of one year follow up from insertion
|
estimated time of one year follow up from insertion
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Expulsion rate
Time Frame: On first visit after menstruation from insertion, 3 month from insertion and after one year
|
On first visit after menstruation from insertion, 3 month from insertion and after one year
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Aya Mohr Sasson, M.D, Sheba Medical Center, Tel-Hashomer
Publications and helpful links
General Publications
- Heikinheimo O, Gissler M, Suhonen S. Age, parity, history of abortion and contraceptive choices affect the risk of repeat abortion. Contraception. 2008 Aug;78(2):149-54. doi: 10.1016/j.contraception.2008.03.013. Epub 2008 May 27.
- Apter D. Contraception options: Aspects unique to adolescent and young adult. Best Pract Res Clin Obstet Gynaecol. 2018 Apr;48:115-127. doi: 10.1016/j.bpobgyn.2017.09.010. Epub 2017 Sep 28.
- Hubacher D, Cheng D. Intrauterine devices and reproductive health: American women in feast and famine. Contraception. 2004 Jun;69(6):437-46. doi: 10.1016/j.contraception.2004.01.009.
- Goodman S, Hendlish SK, Reeves MF, Foster-Rosales A. Impact of immediate postabortal insertion of intrauterine contraception on repeat abortion. Contraception. 2008 Aug;78(2):143-8. doi: 10.1016/j.contraception.2008.03.003. Epub 2008 May 14.
- Lahteenmaki P, Luukkainen T. Return of ovarian function after abortion. Clin Endocrinol (Oxf). 1978 Feb;8(2):123-32. doi: 10.1111/j.1365-2265.1978.tb02160.x.
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- 4671-17-SMC
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Contraception
-
NCT03165838CompletedPregnancy Related | Contraception | Contraception Behavior | Contraception Use
-
NCT00258076CompletedFemale Contraception | Contraception
-
NCT00258063Completed
-
NCT02213874CompletedContraception | Contraception Behavior
-
NCT01178125CompletedFemale Contraception | Contraception
-
NCT00254865Completed
-
NCT00236795CompletedFemale Contraception | Contraception
-
NCT00236769CompletedFemale Contraception | Contraception
-
NCT00261482Completed
-
NCT02866279CompletedContraception | Breastfeeding | Postpartum Contraception
Clinical Trials on Intrauterine system
-
NCT07381569Not yet recruiting
-
NCT06577168Not yet recruiting
-
NCT03657602Completed
-
NCT05475756Recruiting
-
NCT01839136Terminated
-
NCT03731689UnknownIntrauterine Adhesions
-
NCT00675142Completed
-
NCT05999591Completed