VitaFlow™ Transcatheter Aortic Valve System Post-market Study-The LAUNCH Study
A Prospective, Multi-center, Post-market Registry Study Evaluating Safety and Effectiveness of the Microport™CardioFlow VitaFlow™Transcatheter Aortic Valve System for the Treatment of Severe Aortic Stenosis
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Zhujun Cai, PhD
- Phone Number: (86)(21)38954600
- Email: zjcai@micoport.com
Study Contact Backup
- Name: Jie Bi
- Phone Number: (86)(21)38954600
- Email: jbi@micoport.com
Study Locations
-
-
Shanghai
-
Shanghai, Shanghai, China
- Recruiting
- Zhongshan Hospital
-
Contact:
- Daxin Zhou, Prof
- Phone Number: 13801641512
- Email: zhou.daxin@zs-hospital.sh.cn
-
Shanghai, Shanghai, China
- Not yet recruiting
- Ruijing Hospital,Jiaotong University School of Medicine
-
Contact:
- Ruiyan Zhang, Prof
- Phone Number: 13601911729
- Email: zhangruiyan@263.net
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Age≥70 years;
- Symptomatic , calcified, severe, degenerative, native aortic valve stenosis : peak velocity ≥4.0m/s, or mean transvalvular gradient ≥40mmHg(1 mmHg=0.133kPa), or aortic valve area<0.8cm² (or EOA index<0.5cm²/m²);
- The patients considered to be not suitable for surgical aortic valve replacement (SAVR);
- The patient has been informed of the nature of the study, is willing to enroll in the study by signing a patient informed consent and agreeing to the scheduled follow up requirement.
Exclusion Criteria:
- Aortic root anatomy not suitable for the implantation of the transcatheter aortic valve;
- Vascular diseases or anatomical condition preventing the device access;
- Previous implantation of mechanical or bioprosthesis valve in the aortic position;
- Known hypersensitivity or contraindication to all anticoagulation/antiplatelet regimens, to nitinol, contrast media or other relevant elements;
- Ongoing sepsis, including active endocarditis;
- Estimated Life expectancy< 12 months;
- Participating in another trial and the primary endpoint is not achieved.
- Inability to comply with the clinical investigation follow-up or other requirements.
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
single arm, treatment group
Subjects in the treatment group will be implanted with the VitaFlow™ Transcatheter Aortic Valve System
|
VitaFlow™ Transcatheter Aortic Valve System contains a valve stent-VitaFlow™ Aortic Valve, a delivery system-VitaFlow™ Delivery System,loading tools, a balloon dilatation catheter, and an introducer set
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Rate of all-cause mortality at 12 months post implantation
Time Frame: 12 months post implantation
|
Rate of all-cause mortality including cardiovascular and non-cardiovascular death
|
12 months post implantation
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Valve function-mean transvalvular gradient
Time Frame: at discharge, 30 days, 1 year and annually up to 5 years post implantation
|
Mean transvalvular gradient measured by transthoracic echocardiography (TTE)(in mmHg)
|
at discharge, 30 days, 1 year and annually up to 5 years post implantation
|
|
Valve function-effective orifice area
Time Frame: at discharge, 30 days, 1 year and annually up to 5 years post implantation
|
Effective orifice area measured by transthoracic echocardiography (TTE)(in cm^2)
|
at discharge, 30 days, 1 year and annually up to 5 years post implantation
|
|
Valve function-degree of prosthetic valve regurgitation
Time Frame: at discharge, 30 days, 1 year and annually up to 5 years post implantation
|
Degree of prosthetic valve regurgitation, including paravalvular leak and intravalvular regurgitation measured by transthoracic echocardiography (TTE)
|
at discharge, 30 days, 1 year and annually up to 5 years post implantation
|
|
Rate of safety events according to VARC2
Time Frame: at immediate, 30 days, 1 year and annually up to 5 years post implantation
|
Rate of safety events according to VARC2 including all-cause mortality, myocardial infarction, stroke, bleeding, acute kidney injury, vascular complications, new permanent pacemaker implantation
|
at immediate, 30 days, 1 year and annually up to 5 years post implantation
|
|
Rate of other TAVI-related complications
Time Frame: at immediate, 30 days, 1 year and annually up to 5 years post implantation
|
Rate of other TAVI-related complications including conversion to open surgery, unplanned use of cardiopulmonary bypass, coronary obstruction, ventricular septal perforation, mitral valve apparatus damage or dysfunction, cardiac tamponade, endocarditis, valve thrombosis, valve mal-positioning, TAV-in-TAV, valve related dysfunction requiring repeat procedure (TAVI,SAVR,BAV)
|
at immediate, 30 days, 1 year and annually up to 5 years post implantation
|
|
Rate of device success
Time Frame: at immediate post implantation
|
Rate of device success, assessed by the access, delivery, deployment and implantation of the device and the prosthetic valve function
|
at immediate post implantation
|
|
Rate of balloon pre-dilatation success
Time Frame: at immediate post implantation
|
Rate of balloon pre-dilatation success, assessed by the access, delivery, pre-dilatation and retrieval of the balloon catheter
|
at immediate post implantation
|
|
Rate of balloon post-dilatation success
Time Frame: at immediate post implantation
|
Rate of balloon pre-dilatation success, assessed by the access, delivery, post-dilatation and retrieval of the balloon catheter
|
at immediate post implantation
|
|
Rate of procedure success
Time Frame: at immediate post implantation
|
Rate of procedure success, assessed by the device success and peri-procedural complications
|
at immediate post implantation
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ANTICIPATED)
Primary Completion
Study Completion (ANTICIPATED)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- LAUNCH-2020
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Aortic Valve Stenosis
-
NCT07620925RecruitingAortic Stenosis | Calcific Aortic Valve Disease | Chronic Coronary Syndrome | Calcific Aortic Stenosis
-
NCT07144189RecruitingAortic Stenosis | Low-gradient Aortic Stenosis
-
NCT07450196Not yet recruiting
-
NCT07278310RecruitingAortic Stenosis | Symptomatic Severe Native Aortic Stenosis
-
NCT05712161Active, not recruitingAortic Stenosis | Aortic Valve Calcification | Severe Aortic Valve Stenosis | Symptomatic Aortic Stenosis
-
NCT07456280Not yet recruitingCardiovascular Diseases | Severe Aortic Valve Stenosis
-
NCT07335900RecruitingSevere Aortic Valve Stenosis
-
NCT07304427CompletedSevere Aortic Stenosis | Transcatheter Aortic Valve Replacemen
-
NCT07479992Recruiting
-
NCT07205068Recruiting
Clinical Trials on VitaFlow™ Transcatheter Aortic Valve System
-
NCT04655742UnknownAortic Valve Stenosis
-
NCT04414878RecruitingAortic Stenosis
-
NCT03575039Not yet recruitingAortic Valve Stenosis
-
NCT05977257Not yet recruitingAortic Valve Stenosis | Aortic Valve Disease
-
NCT05864456RecruitingAortic Valve Stenosis
-
NCT03495050Unknown
-
NCT06375590Not yet recruitingBicuspid Aortic Valve
-
NCT06381271RecruitingAortic Valve Regurgitation
-
NCT06379386RecruitingAortic Valve Stenosis and Insufficiency