An Innovative Taping Technique for Improved Intravenous (IV) Catheter Securement
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Pete Kovatsis, MD
- Phone Number: 617-355-7737
- Email: pete.kovatsis@childrens.harvard.edu
Study Contact Backup
- Name: Samuel Kim
- Phone Number: 617-919-3692
- Email: samuel.kim@childrens.harvard.edu
Study Locations
-
-
Massachusetts
-
Boston, Massachusetts, United States, 02115
- Boston Children's Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Employees of Boston Children's Hospital
Exclusion Criteria:
- Individuals under the direct supervision of any study investigators
- Individuals with excessive hair in/near the antecubital fossa region on either arm
- Individuals with fragile and/or non-intact skin in/near the antecubital fossa region
- Individuals who have adhesive allergies
- Individuals who have already participated
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Retrograde Directional Test
Subjects during the Retrograde Directional Test will have the three taping methods placed on their left and/or right antecubital fossa region to superficially secure an IV catheter (i.e., the catheter will be placed on top of the participant's skin and not in the vein but will be taped as if the catheter was placed intravenously).
Six total measurements will be obtained of which three will be using the Retrograde Directional Test (i.e., each taping method will undergo testing for each directional method).
The order of placing the different taping methods and the direction testing will be randomized.
|
Subjects will be asked to have the novel taping method placed on their left and right antecubital fossa region, superficially taping an IV catheter.
Subjects will be asked to have the BCH emergency department taping method placed on their left and right antecubital fossa region, superficially taping an IV catheter.
Subjects will be asked to have the Chevron taping method placed on their left and right antecubital fossa region, superficially taping an IV catheter.
|
|
Active Comparator: 90 Degrees Directional Test
Subjects during the 90 Degrees Directional Test will have the three taping methods placed on their left and right antecubital fossa region, superficially taping an IV catheter (i.e., the catheter will be placed on top of the participant's skin and not in the vein but will be taped as if the catheter was placed intravenously).
Six total measurements will be obtained of which three will be using the 90 Degrees Directional Test (i.e., each taping method will undergo testing for each directional method).
The order of placing the different taping methods and the direction testing will be randomized.
|
Subjects will be asked to have the novel taping method placed on their left and right antecubital fossa region, superficially taping an IV catheter.
Subjects will be asked to have the BCH emergency department taping method placed on their left and right antecubital fossa region, superficially taping an IV catheter.
Subjects will be asked to have the Chevron taping method placed on their left and right antecubital fossa region, superficially taping an IV catheter.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The Force (Newtons) Required to Dislodge an IV Catheter Secured in the Retrograde Direction.
Time Frame: Until the tape is dislodged- approximately 15 seconds
|
We will examine the maximum force the taping methods can withstand as measured by the force gauge in the retrograde direction, distally from the insertion site.
|
Until the tape is dislodged- approximately 15 seconds
|
|
The Force (Newtons) Required to Dislodge an IV Catheter Secured in a 90 Degrees Direction.
Time Frame: Until the tape is dislodged- approximately 15 seconds
|
We will examine the maximum force the taping methods can withstand as measured by the force gauge in a 90 degrees direction, medially from the insertion site.
|
Until the tape is dislodged- approximately 15 seconds
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Pete Kovatsis, MD, Boston Children's Hospital
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- IRB-P00043126
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.