Efficacy and Safety of the ExPRESS Implant Versus Deep Sclerectomy in Combined Surgery

June 26, 2017 updated by: Institut Catala de Retina

Efficacy and Safety of the ExPRESS Implant Versus Deep Sclerectomy in Combined Surgery: Prospective, Multi-center, Comparative Study

The Ex-PRESS Glaucoma Filtration Device is a small, non-valved implant that was designed to lower intraocular pressure (IOP) by shunting aqueous humor from the anterior chamber into the subconjunctival space. The implant was developed in response to the need for more straightforward, standardized and safe surgical technique than standard filtration surgery. No iridectomy and no sclerectomy is needed if an Ex-PRESS device is implanted under a partial-thickness scleral flap. This may reduce surgical time and complications when compared to a standard trabeculectomy.

In some studies it has been found to be safe and effective with few complications, even in high-risk patients. No previous studies have compared filtration surgery with Ex-Press implant to deep sclerectomy.

Study Overview

Detailed Description

Hypothesis:

In combined procedure (cataract and filtering surgery), the effect of Ex-PRESS device has similar efficacy reducing intraocular pressure than non penetrant deep sclerectomy and with good level of safety.

Objective:

To evaluate and compare the efficacy and safety at 12 months of the filtering surgery with the Ex-PRESS device with that of deep sclerectomy.

Methods:

Design: Multi-center, prospective, simple-blind, randomized study.

Primary variable:

1. Intraocular pressure.

Secondary variables:

  1. Success rate at IOP <18
  2. Frequency and type of complications
  3. Number of hypotensive drugs needed.

Sample size calculation: Accepting an alfa risk of 0.05 and a beta risk of 0.20 in a two-sided Student's T-test, 50 subjects are necessary in first group and 50 in the second to recognize as statistically significant a difference greater than or equal to 10% in IOP, with a common standard deviation of 17%. A drop-out rate of 8% has been anticipated. If no drop-out rate is considered, the number of needed subjects is 92 (46 per group).

If the drop out rate is more than 8%:

  1. If the recruitment period is open, another subjects will be included.
  2. If the recruitment period os close, the inclusion of another subject will be evaluated to maintain the statistic power of the study.

Method

-Single blinded. Each patient will be assigned to one of the two arms (Ex-PRESS or Deep sclerectomy) the same day of surgery. The surgeon will be informed of the randomization result just before surgery by the study coordinator.

Pre-operative examinations:

History summarizing previous surgical procedures, intraocular pressure while on treatment, target pressure at the discretion of the surgeon, visual field (SITA standard 24-2), gonioscopy, and a detailed description of the optic disc / nerve fiber layer by a glaucoma specialist was performed in all subjects included.

Post-operative examinations

Visits were undertaken at 1 day, 1 week, 2 weeks, 3 weeks, 1 month, 2 months, 3 months, 6 months, and 12 months.

Tests:

  • visual fields (month 12)
  • gonioscopy (month 12)
  • intraocular pressure (all visits)
  • optic disc examination (all visits, under dilation at 3 and 12 month)
  • Pachymetry (preop exam)
  • endothelial cell count (months 3 and 12)
  • Bleb morphology (month 1 and 12)
  • methodic registration of complications (all visits)

A specific CRF was designed with all variables and data required for the study which included a long list of individual potential complications

Pre-operative treatment. Prostaglandin analogues will be discontinued one week before surgery, but the rest of hypotensive drugs will be maintained until the day of surgery

Surgery. Each patient was assigned to one of the two arms (Ex-PRESS or Deep sclerectomy) the same day of surgery. The surgeon wil be informed of the randomization result just before surgery by the study coordinator.

The surgical technique is as follows: retro/peribulbar o subtenon's anesthesia, superior rectus or corneal traction suture, phacoemulsification through 2.1 to 2.8 mm incision with IOL implantation, a fornix-based conjunctival flap, sufficient but not excessive cauterization, application MMC 0,2 mg/ml for 2 minutes under the conjunctiva, then MMC was washed out with 50 ml of saline solution, then and according to the randomization result a scleral flap (5x5 mm in the NPDS, 4x4 mm in the Ex-Press group) is dissected.

Group 1. Then the Ex-PRESS device was placed according to the manufacturer's instructions and its position in the anterior chamber was verified by the surgeon.

Group 2. Deep sclerectomy (NPDS) was performed by dissecting a Deep scleral flap (4x4 mm) and peeling the trabeculo-descement membrane. A Esnoper (AJL, Vitoria, Spain) device was positioned under the external scleral flap and fixated with a 10/0 nylon suture.

Suture Nylon 10/00 suture was used to place four or five stitches in the Ex-Press group and 2 stitches in the NPDS group. Then a hermetic conjunctival suture was performed at the limbus with 10/0 nylon.

Post-operative treatment. All patients instilled Moxifloxacin Antibiotic every 6 hours for 1 week, Dexamethasone (every 2 hours for 1 month, every 4-6 hours on the second month and gradually tapered on the third month according to surgeon's instructions). Atropine was also used at the discretion of the surgeon when clinical finds recommended its use.

Suture lysis or gonio-punture were indicated and performed at the discretion of the surgeon, and they were always registered in the CRF.

Subconjunctival injections of anti-fibrotic agents and/or bleb needling were allowed and performed at the discretion of the surgeon.

DATA ANALYSIS Variables will be checked for normality using the Shapiro-Wilk test. The mean and standard deviation is going to be used to describe normally distributed variables which will be compared between independent groups using the Student t test. Variables that are found to be not normally distributed will be described by median and quartiles, and their comparison between independent groups wil be performed using the Mann-Whitney U test.

Study Type

Interventional

Enrollment (Actual)

98

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Barcelona, Spain, 08017
        • Institut Català de Retina

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

14 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. Diagnosis of open-angle glaucoma. Points a, b and c will be required:

    1. Glaucomatous visual field. Defined as the field presenting at least:

      • A group of 3 or more points with p < 5% in the pattern deviation map AND
      • One of them with a p < 1% in the pattern deviation map AND
      • Repeated in at least 2 VF.
    2. Glaucomatous optic nerve. Defined as the optic nerve observed in color photographs presenting:

      • Thinning of the neuroretinal rim that can be demonstrated by an alteration in the ISNT rule.
      • Presence of a notch "or"
      • Presence of papillary splinter hemorrhage "or"
      • Presence of a nerve fiber layer defect "or"
      • Cup to disc (C/D) ratio asymmetry > 0.3 that cannot be explained by asymmetry in the optic disc size "or"
      • C/D ratio > 0.8 that cannot be explained by a large optic disc size
    3. III or IV angle in Shaffer classification
  2. Disease poorly controlled with medical treatment and/or laser at the discretion of the ophthalmologist (progression, higher than targeted pressure, poor compliance…)
  3. Cataract with visual acuity between 0,1 (20/200) and 0.8 (20/25)

Exclusion Criteria:

  1. Inflammatory, neovasular, closed-angle, normotensive glaucoma secondary to corticoids, or any type of glaucoma with advanced degree of functional lesion (Mean Defect < -20 dB)
  2. Previous glaucoma surgery
  3. Previous intraocular ocular surgery

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Filtration surgery with Express
Filtration surgery with Ex-PRESS + cataract extraction (Cataract surgery and IOL implantation)
Filtration surgery with Ex-PRESS
Cataract surgery and IOL implantation
Active Comparator: Non penetrating surgery
- Filtration surgery with Non penetrating deep sclerectomy + cataract extraction (Cataract surgery and IOL implantation)
Cataract surgery and IOL implantation
Non penetrating deep sclerectomy

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Intraocular pressure
Time Frame: Up to 12 months
mmHg
Up to 12 months

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Success rate at IOP <18
Time Frame: Up to 12 months
percentage of patients with < of 18 mmHg in intraocular pressure
Up to 12 months
Number of participants with adverse events assesed by questionare in case report file.
Time Frame: Up to 12 months

Bullet list of complications to check for at each study visit from the date of randomization upt to 12 months

List of complications in Case report file:

Avascular bleb Bleb fibrosis Choroidal effusion Corectopia Corneal edema Corneal erosion Cystoid macular edema Descemet folds Epiretinal membrane Fibrin IOL Foreign body sensation Hematic tyndall Hypotony > 1 month Hypotony Maculopathy Iris incarceration Iris synechiae Lamellar macular hole Posterior capsule opacity Postoperative shunt closure Postoperative uveitis Seidel (early) Shallow anterior chamber Subconjunctival hemorrhage Tenon Cist Transient hypotony VA declined > 2 Snellen lines Vitreous in anterior chamber

Up to 12 months
Number of hypotensive medications needed
Time Frame: Up to 12 months
Number of drugs prescribed by investigator to keep IOP under target from the date of randomization up to 12 months
Up to 12 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

February 1, 2012

Primary Completion (Actual)

June 1, 2015

Study Completion (Actual)

June 1, 2016

Study Registration Dates

First Submitted

December 21, 2011

First Submitted That Met QC Criteria

June 26, 2017

First Posted (Actual)

June 28, 2017

Study Record Updates

Last Update Posted (Actual)

June 28, 2017

Last Update Submitted That Met QC Criteria

June 26, 2017

Last Verified

June 1, 2017

More Information

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Ocular Hypertension

Clinical Trials on Filtration surgery with Ex-PRESS

Subscribe