- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT03226184
Sterilizing Effects of the Erbium:YAG Laser Upon Metal Implants
Background:
Even today, postoperative infection is the commonest complications after surgery although all aseptic precautions are taken and causes significant postoperative morbidity, mortality, prolongs hospital stay, and increases costs. Infections that are related to orthopaedic procedures are considered particularly severe when implantation materials are used which further increases the risk of infection and holds the risk of biofilm formation. This is of particular concern since biofilm-mediated infections are difficult to diagnose and effective treatments are lacking. Therefore, new strategies for implant infection are currently being researched worldwide. In this study the relatively new approach for infection control by using an Er:YAG laser was adapted to an orthopaedic and traumatologic setting. This laser vaporizes all water containing cells in a very effective, precise and predictable manner and shows only a minimal thermal damage.
Methods:
For preliminary testing 42 steel pins and 42 plates were cultivated with cocultures for 2 weeks. The minimally necessary laser energy for biofilm removal was determined. We subsequently compared the effectiveness of biofilm removal with the Er:YAG laser and a cleansing of the metal implants with Octenidine soaked gauze. The temperature rise within the metal during the laser procedure was also measured.
In order to achieve an approximation to a clinical setting we want to compared the same effectiveness of biofilm removal similarly on steel pins directly after explantation from patients treated with external fixators for at least 2 weeks. Sonication and SEM will be used for analysis.
Preliminary Results Laser fluences exceeding 2.8J/cm2 caused a complete extinction of all living cells by a single laser impulse. Temperature rise within the implant is dependent on repetition frequency but overall negligible.
The effectiveness of biofilm removal after cleansing with Octenidine soaked gauze and irradiation with the Er:YAG laser will be evaluated on cultivated and extracted pins.
Conclusions We want to compare the effectiveness of the Er:YAG laser and Octenidine in the removal of biofilms from half-pins. We hypothesize that thee Er:YAG laser offers a secure, complete and non toxic removal of all kinds of pathogens from steel implants without damaging the implant or possible development of resistances. The precise non-contact removal of adjacent tissue could be an advantage over other disinfectants.
Level of Evidence (II-a)
Clinical Relevance:
Having one more arrow in the quiver for disinfection of percutaneous implants or for septic revision surgery when osteosynthesis equipment or arthroplasties are meant to be left in place would be extremely desirable.
Study Overview
Status
Study Type
Enrollment (Anticipated)
Contacts and Locations
Study Locations
-
-
-
Vienna, Austria, 1090
- Recruiting
- University Clinic of Traumatology, Medical University of Vienna
-
Contact:
- Lukas K Kriechbaumer, MD
- Phone Number: 57156 +43 (0) 5 7255
- Email: lukikriechbaumer@hotmail.com
-
Contact:
- Wolfgang Happak, Prof. MD
- Phone Number: 69860 +43 (0)1 40400
-
Sub-Investigator:
- Wolfgang Happak, Prof. MD
-
Principal Investigator:
- Lukas Kriechbaumer, MD
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
All patients that are treated with external fixators for at least 2 weeks and patients whose implants have to be removed during septic revision surgery.
Exclusion Criteria:
-
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Completeness of biofilm removal
Time Frame: 2 years
|
Is the Er:YAG laser able to remova a microbial biofilm from cultivated or infected implants
|
2 years
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Side effects
Time Frame: 2 years
|
Are there side effect to be expected from laser Irradiation either for the implant or for the surrounding tissue in a possible clinical setting
|
2 years
|
Collaborators and Investigators
Sponsor
Collaborators
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Anticipated)
Study Completion (Anticipated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- 2167/2013
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Orthopedic Devices Associated With Misadventures, Prosthetic and Other Implants, Materials and Accessory Devices
-
Louisiana State University Health Sciences Center...RecruitingPatient Satisfaction | Fracture | Pediatric | Orthopedic Devices Associated With Misadventures, Surgical Instruments, Materials and Devices (Including Sutures)United States
-
Sean Mc MillanDr. Sean Mcmillan; Dr. Thomas Plut; Dr. Nathan BodinRecruitingOrthopedic Devices Associated With MisadventuresUnited States
-
Cairo UniversityCompletedOrthopedic Disorder | Orthopedic Devices Associated With Misadventures
-
University of Southern DenmarkUnknownCalcaneus Fracture | Orthopedic Devices Associated With MisadventuresDenmark
-
National Taiwan University HospitalNot yet recruitingPerioperative Care | Patient Safety | Catheterization, Central Venous | Equipment Design | Anesthesiology Devices Associated With Misadventures, Diagnostic and Monitoring DevicesTaiwan
-
University of Sao PauloCompletedInfluence of Low-level Laser Therapy on Stability and Displacement of Orthodontic Miniscrew ImplantsDisplacement of Other Bone Devices, Implants and Grafts | Mechanical Complication of Other Bone Devices, Implants and Grafts
-
Balgrist University HospitalCompletedAntibiotic Side Effect | Infection, Surgical Site | Orthopedic Devices Associated With MisadventuresSwitzerland
-
National Taiwan University HospitalUnknownDiagnostic and Monitoring Anesthesiology Devices Associated With Adverse IncidentsTaiwan
-
EndoChoice Innovation Center, Ltd.CompletedMiscellaneous Gastroenterology and Urology Devices Associated With Adverse Incidents, Not Elsewhere Classified
-
C. R. BardCompletedStenosis of Vascular Prosthetic Devices, Implants and GraftsUnited States