Symax International Study

March 16, 2018 updated by: Maastricht University Medical Center

5 Year Clinical and Radiographic Follow-up of the Uncemented Symax Hip Stem in an International Study

The uncemented Symax hip stem is developed through optimization of the uncemented Omnifit hip stem. The Symax stem design combines an anatomical anteverted proximal geometry with a straight distal section. The proximal part is coated with a biomimetic hydroxyapatite (HA) coating for improved osseointegration to enhance load transfer and to minimize proximal bone loss. The distal part is treated with an anodization surface treatment in order to prevent distal bone apposition, which is expected to prevent distal loading and reduce proximal stress shielding. Aim of this study is to report mid-term clinical performance and evaluate whether the radiographic features are in line with the design principles of the Symax hip in an international clinical study with 5 years of follow-up.

Study Overview

Status

Completed

Intervention / Treatment

Study Type

Interventional

Enrollment (Actual)

80

Phase

  • Not Applicable

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 70 years (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Patients requiring uncemented primary total hip arthroplasty (osteoarthritis, avascular necrosis and/or post-traumatic arthritis), age between 18-70 years, BMI less or equal to 35.

Exclusion Criteria:

  • Patients with bilateral hip complaints, impaired cognitive function and use of medication or illness influencing bone metabolism.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Other: Symax uncemented hip stem
The Symax hip stem is an uncemented design forged from Ti6Al4V alloy (Stryker EMEA). Primary mechanical stability is provided by anatomical metaphyseal geometry. The hip stem features a size dependent anteversion, neck length and offset, with a CCD angle of 128°. Secondary biological stability is accomplished by fast osseous integration due to the BONIT-HA coating on the metaphyseal part of the stem.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Change of Harris Hip Score (HHS) during follow-up
Time Frame: Preoperative HHS and postoperatively change in HHS at 6 months, 1 year, 2 years, 3 years and 5 years
A hip specific functional score
Preoperative HHS and postoperatively change in HHS at 6 months, 1 year, 2 years, 3 years and 5 years

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Radiographic evaluations
Time Frame: Immediately postoperative radiograhpic evaluation as baseline and changes in radiography at follow-up 6 months, 1 year, 2 years, 3 years and 5 years we evaluated the radiograhip evaluations again
Radiographic evaluations per Gruen zone and comparison between two assessment teams
Immediately postoperative radiograhpic evaluation as baseline and changes in radiography at follow-up 6 months, 1 year, 2 years, 3 years and 5 years we evaluated the radiograhip evaluations again

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

November 2, 2004

Primary Completion (Actual)

October 11, 2010

Study Completion (Actual)

October 11, 2010

Study Registration Dates

First Submitted

January 15, 2018

First Submitted That Met QC Criteria

March 16, 2018

First Posted (Actual)

March 19, 2018

Study Record Updates

Last Update Posted (Actual)

March 19, 2018

Last Update Submitted That Met QC Criteria

March 16, 2018

Last Verified

January 1, 2018

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Hip Osteoarthritis

Clinical Trials on Symax uncemented hip stem

Subscribe