Multi-level Dimensional Changes at Immediate Implant Sites

June 12, 2020 updated by: Tiago Borges, Universidade Católica Portuguesa

Linear and Volumetric Analysis on the Effect of Customized Healing Abutments at Maxillary Immediate Implant Sites: a Prospective Randomized Clinical Trial

Studies evaluating the use of customized healing screws/abutments in immediate implant placement have been performed, aiming to assess possible advantages with the use of this treatment modality. Despite the existence of these investigations, there is a lack of information regarding a digital approach to evaluate in an objective manner soft and hard tissue dimensional changes at this treatment modality.

Study Overview

Status

Completed

Detailed Description

Studies evaluating the use of customized healing screws/abutments have been performed aiming to assess possible advantages with the use of this treatment modality. Despite the existence of these investigations, there is a lack of information regarding a digital approach to evaluate in an objective manner soft and hard tissue dimensional changes.

The aim of this study is to perform a volumetric analysis evaluating peri-implant tissues dimensional changes on the effect of using customized healing abutments compared with the use of collagen matrices as socket sealing options in maxillary immediate implant placement.

The present study was designed as a prospective, randomized, controlled clinical trial with a parallel-group design, to document the response of using a customized healing abutment in maxillary immediate implants. Twenty-eight consecutive patients in need of a single implant restoration in the maxillary arch following tooth extraction were included in this study.

All patients were treated with cylindrical shape implants (OsseoSpeed EV™, AstraTech Implant System, Dentsply Implants, Möhndal, Sweden) with a narrow diameter internal connection platform following the surgical sequence protocol provided by the manufacturer. The implant was placed in a correct three-dimensional position, engaging the palatal and apical bone to achieve high primary stability. (Buser et al. 2004) After implant insertion, a gap of at least 2 mm between the inner cortical buccal bone plate and the implant surface was filled with DBBM material (Symbios®, Dentsply Implants, Möhndal, Sweden).

The two groups differ in the type of socket sealing. Control group fresh sockets were sealed with a resorbable collagen membrane (Mucograf Seal®, Geistlish Biomaterials, Wolhusen, Switzerland) stabilised with single interrupted 6/0 polyamide sutures (SeralonTM, Serag-Wiessner, Nalia, Germany), whereas test group received a healing abutment customized with a composite resin material allowing to close the socket without sutures.

Clinical examination and image acquisition Examination protocol and data collection consisted of four appointments: 1) T0 (flapless tooth extraction and implant insertion; 2) T1 (1-month follow-up after implant placement; 3) T2 (4-month follow-up after implant insertion) and 4) T3 (1-year postoperative follow-up). An intraoral scan of the upper arch (Cerec Omnicam®, Sirona Dental Systems GmbH, Bensheim, Germany) and a CBCT radiographic evaluation (Ortophos XG 3D®, Sirona Dental Systems GmbH, Bensheim, Germany) were performed followed by tooth extraction and implant placement (T0). At this point, two clinical parameters were assessed with a periodontal probe to the nearest millimetre: BID (distance between implant shoulder and the buccal bone plate) and KM (distance between the gingival groove and the mucogingival junction). Intraoral scans were completed post-implant placement at one month (T1), four months (T2) and twelve months (T3). In all follow-up appointments hygiene instructions were given to the patients and a periodontal care was executed when necessary.

Matching digital models All digital models were exported from the intraoral scanner in STL format. The T0 and T1, T0 and T2, and T0 and T3 STL files were overlapped and a strict alignment was made into one common coordinate system. A final alignment was done through the best fit alignment algorithm for a perfect match of digital models and executed with settings adjusted to the oral cavity.

After the superimposition of digital models, a colour map was created to quantitatively analyse the three-dimensional changes occurring in the surgical areas and adjacent tissues. Green areas correspond to the perfect alignment of the model. The variation between yellow and red represents variations of volumetric increase, whereas the variations between light blue and dark blue represent the variations of volumetric decrease. A region of interest (ROI) with 10 section planes, perpendicular to the coronal section of the tooth, was computed at buccal and palatal aspect (Figure 2). These sections were set at the most apical point of the gingival margin and ended 5 mm above it. Mesially and distally, a line passing through the interproximal area limited the region of interest. The same ROI was used in each patient, at the different comparison points. The intersection of these sections with the overlapping models allowed the linear changes to be obtained in each area. The Mean Buccal Change (MBC0-1, MBC0-2, and MBC0-3) and Mean Total Change (MTC0-1, MTC0-2 and MTC0-3) were calculated in millimetres (mm) to evaluate the changes that occurred in peri-implant contour (Figure 3).

Digital models superimposed in Geomagic Control X® were exported to Materialise Magics® for volumetric assessment. A volumetric ROI was manually selected with "Cut or Punch" function using interproximal areas as mesial and distal limits. All cuts were performed in the same way in all digital models so that all measurements were carried out in the same areas. ROI volume at T0 was computed for further comparison with consecutive volume variation values (Figure 4). The 3D-analysis was conducted with "Boolean" functions, which allowed researchers to obtain the volume variation in each time point from different variables like the Buccal Volume Variation (BVv0-1, BVv0-2, and BVv0-3) and Total Volume Variation (TVv0-1, TVv0-2, e TVv0-3), computed in cubic millimetres (mm3). To allow a direct comparison of different sites at different time points, relative percentages of these variables were calculated based on the ROI volume at T0 (Szathvary et al. 2015). All measurements were recorded to the nearest 0.01 mm.

Radiographic assessment The acquisition of radiographic images was performed with a volumetric dimension of 8 x 8 cm for 14s with the tomography acquisition protocol, with a voxel size of 0.1 mm in HD mode. The CBCT images were imported in a DICOM format to Mimics® software to perform the measurements. Buccal plate thickness (BT) was assessed for 3D radiographic analysis to evaluate the initial features of the alveolar bone. All measurements were obtained through coronal slice reconstructions, using an adjacent line to the sinus/nasal plate as a reference (Figure 5). BT was measured 1 mm above the coronal bone margin using a central slice, as well at the mesial and distal slices, ranging 1 mm from the central slice. Mean BT values were obtained as the average values of the three slices. One independent examiner who was not involved in the study executed all measurements.

Statistical analysis The outcome variables were presented as mean values, standard deviation, median and 95% confidence interval. Measurement time (T1, T2 and T3) was considered as a factor and the following as covariates: age, gender, KM height, location, implant length, BID and BT. The statistical analysis was performed using SPSS™ Statistical Package for the Social Sciences, version 21.0 (IBM Corporation, Armonk, NY, USA). The Mann-Whitney U-test was used to disclose differences for continuous non-paired variables. Moreover, the paired Wilcoxon test was used when the normal distribution of the groups was proved. A multiple linear regression model, using the stepwise forward method, was built to analyse the effect of the tested treatment in the main outcome variables throughout the study. All hypothesis tests were conducted at the 5% level of significance.

Study Type

Interventional

Enrollment (Actual)

28

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Viseu, Portugal, 3504-505
        • Universidade Católica Portuguesa /FMD

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • patients with ≥18 years of age;
  • patients who had a failing tooth and needed an implant placing therapy in the aesthetic zone (between 15-25);
  • the failing tooth has adjacent and opposing natural teeth;
  • sufficient mesial-distal and inter-occlusal space for placement of the implant and definitive restoration;
  • had an intact socket wall previously to the extraction;
  • had sufficient apical bone to place an immediate implant with minimum primary stability of 30 N/cm.

Exclusion Criteria:

  • individuals diagnosed with periodontal disease;
  • medical and general contraindications for the surgical procedure;
  • heavy smokers (> 10 cigarettes/day); .an active infection at the implant site.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: TREATMENT
  • Allocation: RANDOMIZED
  • Interventional Model: PARALLEL
  • Masking: SINGLE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
EXPERIMENTAL: Group CA
Customized healing abutment inserted in immediate implant placement.
Dental implant insertion in the same surgical stage of the tooth extraction, consisting in implant placement in the fresh socket.
Other Names:
  • Post extraction immediate implant placement
ACTIVE_COMPARATOR: Group CM
Resorbable Collagen Membrane for socket closure in immediate implant placement.
Dental implant insertion in the same surgical stage of the tooth extraction, consisting in implant placement in the fresh socket.
Other Names:
  • Post extraction immediate implant placement

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Buccal volume variation (BVv)
Time Frame: Baseline (T0); 1 month (T1); 4 months (T2) and 12 months (T3)
Variation of the alveolar volume at the buccal aspect. The 3D-analysis was conducted with "Boolean" functions, which allowed researchers to obtain the volume variation in each time point from different variables like the Buccal Volume Variation (BVv0-1, BVv0-2, and BVv0-3), computed in cubic millimetres (mm3) and To allow a direct comparison of different sites at different time points, relative percentages of these variables were calculated based on the ROI volume at T0.
Baseline (T0); 1 month (T1); 4 months (T2) and 12 months (T3)
Total volume variation (TVv)
Time Frame: Baseline (T0); 1 month (T1); 4 months (T2) and 12 months (T3)
Variation of the alveolar volume at the buccal and palatal side. The 3D-analysis was conducted with "Boolean" functions, which allowed researchers to obtain the volume variation in each time point from different variables like the Total Volume Variation (TVv0-1, TVv0-2, e TVv0-3), computed in cubic millimetres (mm3) and To allow a direct comparison of different sites at different time points, relative percentages of these variables were calculated based on the ROI volume at T0
Baseline (T0); 1 month (T1); 4 months (T2) and 12 months (T3)

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Buccal wall thickness (BT)
Time Frame: baseline
measurement of the facial bone wall. The acquisition of radiographic images was performed with a volumetric dimension of 8 x 8 cm for 14s with the XG 3D tomography acquisition protocol, with a voxel size of 0.1 mm in HD mode. BT was measured 1 mm above the coronal bone margin using a central slice, as well at the mesial and distal slices, ranging 1 mm from the central slice. Mean BT values were obtained as the average values of the three slices. Measurements were made in mm.
baseline

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (ACTUAL)

June 1, 2019

Primary Completion (ACTUAL)

June 8, 2020

Study Completion (ACTUAL)

June 8, 2020

Study Registration Dates

First Submitted

June 9, 2020

First Submitted That Met QC Criteria

June 12, 2020

First Posted (ACTUAL)

June 16, 2020

Study Record Updates

Last Update Posted (ACTUAL)

June 16, 2020

Last Update Submitted That Met QC Criteria

June 12, 2020

Last Verified

June 1, 2020

More Information

Terms related to this study

Other Study ID Numbers

  • 06.2019

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Dental Implant Failed

Clinical Trials on Immediate dental implant placement

Subscribe