Combined Effects of Transcutaneous Spinal Cord Stimulation (tSCS) and Augmented Reality (AR) Training on Pain and Balance in Diabetic Neuropathy Patients.

tSCS and AR-based training have individually shown benefits in neuromotor rehabilitation; no study to date has evaluated their combined effects on pain, balance, lower-limb strength, retention, and vibration sense in diabetic neuropathy. The rationale for combining them lies in their complementary mechanisms: tSCS at 30 Hz activates large-diameter Aβ afferents, inhibiting nociceptive input, enhancing spinal excitability, and facilitating motor activation.

Přehled studie

Detailní popis

In Pakistan, 26.3% of the population is affected, and DN impacts about 40% of cases, with early signs reducing function. (9-11) Standard care includes glycemic control, medications like duloxetine and pregabalin, topical agents, and modalities such as TENS.

Alongside pain, lower-limb strength declines due to motor axonal degeneration and prolonged disuse, (1) limiting mobility and increasing the risk of falls. Balance impairments are frequent in DN and result from compromised proprioceptive input and impaired postural control mechanisms; (4) these deficits are exacerbated by pain-related inactivity and muscular weakness.

Augmented reality (AR) based rehabilitation delivers multisensory feedback, such as visual, vestibular, and proprioceptive inputs, during interactive, task-specific training. It enhances sensorimotor coordination, dynamic postural stability, and proprioceptive reweighting. AR training can improve balance responses, promote lower-limb engagement, and reinforce accurate proprioceptive input.

The tSCS enabled stepping in individuals with complete motor loss, confirming its impact on lower-limb functional recovery. Additionally, this stimulation frequency targets mechano-sensory pathways associated with vibration sense and is believed to support retention of sensorimotor gains through repeated activation of neuroplastic mechanisms at the spinal and cortical levels.

Typ studie

Intervenční

Zápis (Odhadovaný)

36

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní kontakt

Studijní záloha kontaktů

Studijní místa

    • Punjab Province
      • Rawalpindi, Punjab Province, Pákistán
        • Pakistan Railway Hospital

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dospělý
  • Starší dospělý

Přijímá zdravé dobrovolníky

Ne

Popis

Inclusion Criteria:

  • More than or equals to 4 score on Douleur Neuropathique 4 Questionnaire
  • More than or equals to 6 Hz at Neurothesiometer
  • More than or equals to 4 score on the Numeric Pain Rating Scale (NPRS)

Exclusion Criteria:

  • Cognitively compromised (MOCA ≤ 26/30)
  • Metallic implants at skull
  • Shunting
  • Skin allergy

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Léčba
  • Přidělení: Randomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: Transcutaneous spinal cord stimulation and Augmented Reality Group
Transcutaneous spinal cord stimulation will be administered non-invasively using surface electrodes placed over the D12-L1 spinal segment. This segmental level has been shown to effectively engage lower-limb motor and sensory networks across multiple spinal segments. Stimulation will be delivered using the Soterix 1×1 Transcutaneous Electrical Stimulation (TES) unit. Stimulation will be applied at a frequency range of 30 Hz. Pulse duration of 1 ms, and intensity will be set at 2 mA. A ramp-up and ramp-down time of 30 seconds will be used to enhance participant comfort during the start and end of each stimulation session, following standardized electrode placement and safety protocols.
AR-based rehabilitation will consist of interactive balance and coordination tasks conducted in a virtual environment, with real-time visual feedback provided to guide movement accuracy and postural control. The core training block will include five structured modules: interactive kicking exercises to promote ankle and knee coordination; color-target foot-reaching tasks to enhance proprioception and reaction time; virtual obstacle navigation to improve gait and stepping control; static and dynamic balance challenges, such as maintaining posture on virtual planks; and lower-limb strengthening activities, including squats and stepping-based games. Each module will be performed for 5-8 minutes, with brief rest periods between tasks.
Aktivní komparátor: Augmented Reality Group
AR-based rehabilitation will consist of interactive balance and coordination tasks conducted in a virtual environment, with real-time visual feedback provided to guide movement accuracy and postural control. The core training block will include five structured modules: interactive kicking exercises to promote ankle and knee coordination; color-target foot-reaching tasks to enhance proprioception and reaction time; virtual obstacle navigation to improve gait and stepping control; static and dynamic balance challenges, such as maintaining posture on virtual planks; and lower-limb strengthening activities, including squats and stepping-based games. Each module will be performed for 5-8 minutes, with brief rest periods between tasks.
Aktivní komparátor: Transcutaneous spinal cord stimulation Group
Transcutaneous spinal cord stimulation will be administered non-invasively using surface electrodes placed over the D12-L1 spinal segment. This segmental level has been shown to effectively engage lower-limb motor and sensory networks across multiple spinal segments. Stimulation will be delivered using the Soterix 1×1 Transcutaneous Electrical Stimulation (TES) unit. Stimulation will be applied at a frequency range of 30 Hz. Pulse duration of 1 ms, and intensity will be set at 2 mA. A ramp-up and ramp-down time of 30 seconds will be used to enhance participant comfort during the start and end of each stimulation session, following standardized electrode placement and safety protocols.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Numeric Pain Rating Scale (NPRS)
Časové okno: Up to week 5 (baseline/week 1/week 5)
The Numeric Pain Rating Scale (NPRS) is a quick, 11-point measure (0 = no pain to 10 = worst imaginable) commonly used across clinical and research settings. Recent studies demonstrate test-retest reliability ranging from 0.58 to 0.93 (good to excellent), with moderate evidence for a minimal clinically important difference (MCID) of 1.5-2.5 points.
Up to week 5 (baseline/week 1/week 5)
Time Up and Go (TUG)
Časové okno: Up to week 5 (Baseline/week 1/week 5)
The TUG test is a simple, clinically validated tool used to assess dynamic balance and functional mobility. It requires an individual to rise from a seated position, walk three meters, turn, return, and sit down. The TUG demonstrated excellent test-retest reliability, with intraclass correlation coefficients (ICC) ranging from 0.89 to 0.94 across multiple trials.
Up to week 5 (Baseline/week 1/week 5)

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
30 Second Chair Stand Test
Časové okno: Up to week 5 (Baseline/week 1/week 5)
The 30-Second Chair Stand Test is a widely used, performance-based tool for assessing lower-limb strength and functional mobility. Among individuals with type 2 diabetes mellitus, a population commonly affected by diabetic neuropathy, the test has demonstrated excellent reliability. A test-retest intraclass correlation coefficient (ICC) of 0.92, indicating excellent relative reliability. In terms of measurement precision, the standard error of measurement (SEM) was 1.08 repetitions, and the smallest real difference (SRD) was 3 repetitions, reflecting the threshold for clinically meaningful change.
Up to week 5 (Baseline/week 1/week 5)
Neurothesiometer
Časové okno: Up to week 5 (Baseline/Week 1/week 5)
The neurothesiometer is a non-invasive and reliable instrument used to assess vibration perception threshold (VPT). It has demonstrated excellent reliability, with intra-class correlation coefficients (ICCs) exceeding 0.90, indicating strong measurement consistency. A VPT cut-off value of ≥ 6 Hz is indicative of neuropathy. Owing to its ease of use, objective quantification, and ability to detect subclinical neuropathy, the neurothesiometer is highly valuable in clinical practice. Its superior standardization makes it a preferred method for evaluating protective sensation and vibration loss, particularly in individuals with diabetes.
Up to week 5 (Baseline/Week 1/week 5)

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Vrchní vyšetřovatel: Mirza Obaid Baig, MSPT, Riphah International University

Publikace a užitečné odkazy

Osoba odpovědná za zadávání informací o studiu tyto publikace poskytuje dobrovolně. Mohou se týkat čehokoli, co souvisí se studiem.

Obecné publikace

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Odhadovaný)

15. června 2026

Primární dokončení (Odhadovaný)

31. prosince 2026

Dokončení studie (Odhadovaný)

31. ledna 2027

Termíny zápisu do studia

První předloženo

30. dubna 2026

První předloženo, které splnilo kritéria kontroly kvality

1. června 2026

První zveřejněno (Aktuální)

2. června 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

2. června 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

1. června 2026

Naposledy ověřeno

1. června 2026

Více informací

Termíny související s touto studií

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Klinické studie na Diabetické neuropatie

Klinické studie na transcutaneous spinal cord stimulation

Předplatit