- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT06403397
Valutazione dell'impatto dell'utilizzo del pacchetto di manutenzione del monitor
Valutazione dell'impatto dell'utilizzo del pacchetto di manutenzione del monitor sugli allarmi del monitor paziente e sull'affaticamento degli allarmi infermieri
Bedside monitors are frequently used in monitoring vital signs of critically ill patients. Nurses working in healthcare facilities, especially in intensive care units, are required to manage devices with different alarm threshold values, categories, and types of alerts, leading to alarm fatigue. In response to this serious threat to patient safety, the FDA and The Joint Commission worked to develop strategies to address alarm fatigue in 2011. Alarm monitoring, identification of the cause, and silencing are typically performed by nurses. When reviewing alarm control studies in the literature, the CEASE care package developed by Levis et al. in 2019 was encountered. The tool was developed for personalized clinical alarm monitoring for the patient.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Bedside monitors are frequently used in monitoring vital signs of critically ill patients. Patient monitors assist healthcare professionals in continuous monitoring of basic vital signs such as EKG (electrocardiogram), blood pressure, pulse oximetry, respiration, as well as advanced hemodynamic parameters like central venous pressure, pulmonary artery pressure. These devices alert healthcare personnel visually and audibly in case of any abnormality in the monitored parameters. According to the Sentinel Event Alert report published by The Joint Commission (TJC) in 2013, each unit can receive thousands of alarm alerts in a single day. It is stated that 85% to 99% of these alarms are either not related to the patient's clinical condition, false, or do not require any action. This situation leads to necessary alarms being silenced, ignored, or muted, thereby threatening patient safety. Thousands of patient injuries and deaths have been reported due to alarm system errors. The main reasons for alarm errors include failure to recognize the alarm, desensitization in nurses, inadequate training in monitor usage, decreased response time to alarms, deficiencies in device interface design, equipment failures, and staff shortages. Monitor alarms occur in a hierarchy of high, medium, and low priority. Each hierarchical alarm produces a different auditory tone. Clinicians use these alarm tones to determine the urgency level and appropriate alarm response. When clinically irrelevant alarms occur more frequently, there is a higher likelihood of overall alarm fatigue. Nurses working in healthcare facilities, especially in intensive care units, are required to manage devices with different alarm threshold values, categories, and types of alerts, leading to alarm fatigue. Alarm fatigue is defined as healthcare workers becoming desensitized and indifferent to many recurring or simultaneous alarm sounds. In response to this serious threat to patient safety, the FDA and The Joint Commission worked to develop strategies to address alarm fatigue in 2011. The published report emphasizes the need to identify the problem clinically and develop solution strategies tailored to the problem, to be implemented alongside general standard interventions. The report primarily focuses on adjusting alarm parameters appropriately and establishing clinic-specific protocols and procedures. Alarm monitoring, identification of the cause, and silencing are typically performed by nurses. When reviewing alarm control studies in the literature, the CEASE care package developed by Levis et al. in 2019 was encountered. The tool was developed for personalized clinical alarm monitoring for the patient. The name CEASE is formed by combining the initials of the words Communication, Electrodes, Appropriateness, Setup, and Education. Researchers found a decrease in the number of monitor alarms and alarm fatigue levels in nurses after using the CEASE care package. More supportive studies are needed for the widespread adoption of this package in clinics. In this study, the investigators aimed to demonstrate a reduction in unnecessary alarm counts and a decrease in nurse alarm fatigue levels with the use of the CEASE care package.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Şişli
-
Istanbul, Şişli, Turchia (Türkiye), 34394
- Demiroğlu Bilim University
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Working in the intensive care unit,
- Willing to participate in the study voluntarily,
- Nurses willing to use the monitor alarm control tool (for intervention group).
Exclusion Criteria:
- Nurses who leave the intensive care unit during the data collection process and those who do not use the monitor alarm control tool
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Prevenzione
- Assegnazione: Non randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Separare
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Experimental group
|
Before the intervention, the intervention group will first undergo the 'Nurse Identification Form' and the 'Alarm Fatigue Scale'. The current root cause analysis of monitor alarms in the clinical setting will be conducted through the 'CEASE Care Package' and the 'Current Situation Analysis Form'. Each patient monitor in the intensive care unit will be observed and recorded by two observers for a period of 24 hours.The Monitor Alarm Control Tool - "Remember Me" will be attached beneath each monitor to facilitate easier monitoring by nurses. Nurses are expected to use the tool for a period of 15 days. After intervention; Two observers will conduct a re-evaluation using the "CEASE Care Package" and the "Current Status Analysis Form". Monitor alarms will be continuously assessed and recorded for 24 hours. Following the completion of this stage, the "Alarm Fatigue Scale" will be reapplied to the intervention group. |
|
Nessun intervento: Control group
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
The use of the CEASE care package tool will result in a decrease in the number of alarms in the intensive care unit end of the 3 weeks.
Lasso di tempo: 2 months
|
This outcome will measured by Current Situation Analysis Form and CEASE care package tool. |
2 months
|
|
The use of the CEASE care package tool will lead to a reduction in alarm fatigue levels end of the 3 weeks.
Lasso di tempo: 2 months
|
This outcome will measured by alarm fatigue scale. |
2 months
|
Collaboratori e investigatori
Pubblicazioni e link utili
Pubblicazioni generali
- Cvach M. Monitor alarm fatigue: an integrative review. Biomed Instrum Technol. 2012 Jul-Aug;46(4):268-77. doi: 10.2345/0899-8205-46.4.268.
- Schmid F, Goepfert MS, Reuter DA. Patient monitoring alarms in the ICU and in the operating room. Crit Care. 2013 Mar 19;17(2):216. doi: 10.1186/cc12525. No abstract available.
- Joint Commission. Medical device alarm safety in hospitals. Sentinel Event Alert. 2013 Apr 8;(50):1-3. No abstract available.
- De Vaux L, Cooper D, Knudson K, Gasperini M, Rodgerson K, Funk M. Reduction of Nonactionable Alarms in Medical Intensive Care. Biomed Instrum Technol. 2017 Feb;51(s2):58-61. doi: 10.2345/0899-8205-51.s2.58. No abstract available.
- Clark, T., David, Y., & Baretich, M. Impact of clinical alarms on patient safety. ACCE Healthcare Technology Foundation 2006: 1-20
- Sendelbach S, Funk M. Alarm fatigue: a patient safety concern. AACN Adv Crit Care. 2013 Oct-Dec;24(4):378-86; quiz 387-8. doi: 10.1097/NCI.0b013e3182a903f9.
- Graham KC, Cvach M. Monitor alarm fatigue: standardizing use of physiological monitors and decreasing nuisance alarms. Am J Crit Care. 2010 Jan;19(1):28-34; quiz 35. doi: 10.4037/ajcc2010651.
- Association for the Advancement of Medical Instrumentation (2011). A siren call to action: Priority issues from the medical device alarms summit. Clinical Alarms AAMI Summit Proceedings, 5(6).
- Alarm management. Crit Care Nurse. 2013 Oct;33(5):83-6. No abstract available.
- Ashrafi, S., Najafi Mehri, S., & Nehrir, B. (2017). Designing an Alarm Fatigue Assessment Questionnaire: Evaluation of the Validity and Reliability of an Instrument. Journal of Critical Care Nursing, 10(4), 0-0.
- Lewis CL, Oster CA. Research Outcomes of Implementing CEASE: An Innovative, Nurse-Driven, Evidence-Based, Patient-Customized Monitoring Bundle to Decrease Alarm Fatigue in the Intensive Care Unit/Step-down Unit. Dimens Crit Care Nurs. 2019 May/Jun;38(3):160-173. doi: 10.1097/DCC.0000000000000357.
- Erbay-Dalli O, Bagci-Derinpinar K. Adaptation and validation of the Turkish version of the alarm fatigue assessment questionnaire. Enferm Intensiva (Engl Ed). 2024 Apr-Jun;35(2):114-123. doi: 10.1016/j.enfie.2023.09.001. Epub 2023 Oct 5.
- Topcu S, Sari MK, Yilmaz MS, Urkmez DO. Improving nurses' alarm-management performance with a behavioral reminder. Rev Esc Enferm USP. 2026 Sep 21;60:e20250579. doi: 10.1590/1980-220X-REEUSP-2025-0579en. eCollection 2026.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- Remember Me Tool
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Researchers may share IPD data after the completion and publication of the study.
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .