휴대용 자동 초음파 장치와 기존 초음파 장치 간의 바늘 조작 및 정확도의 영향
상업적으로 이용 가능한 두 초음파 장치 사이의 바늘 조작 및 정확도의 영향을 조사하기 위한 무작위 이중 맹검 통제 시험
In this double blinded randomized controlled trial, the investigators would like to compare the effects on needle manipulation when relatively inexperienced sonographist (< 1 year of ultrasound experience) perform ultrasound guided labor epidurals utilizing a traditional handheld ultrasound versus a handheld device that was engineered to provide automated guidance. The primary outcome of this study would be number of needle passes.
연구 개요
상세 설명
Patient will be approached upon admission to labor and delivery floor (Standard of care). The study will be presented to the patient and if they agree, they will be consented. (Study). Upon epidural patient request patient will be randomized to A-US vs B-US based on the randomization table. Ten envelopes will be available with the randomization choice. (Study). The resident will walk in with both US devices into the room (for patient blinding) and perform scan with the device the randomization table called for. (Study). After performing scan and markings of the patients back, the research fellow or clinical fellow will be called into the room to evaluate the number of needle manipulation and provide surveys related to patient and labor analgesia satisfaction. (Study).
Number of needle insertion attempts: defined as advancement of the needle through the skin in an effort to enter the epidural space; a needle requiring withdrawal from the skin for reinsertion is to be counted as an additional insertion attempt. Time to landmark identification: defined as the time interval between the start of needle puncture site identification and the time to first needle puncture attempt. The start time of needle puncture site identification in both the LT and UST corresponds to when the resident physician first places his/her hand on the patient to palpate the back. In both groups, all materials, supplies, and equipment will be prepared and readily available prior to the start of the procedure.
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 연락처
- 이름: Antonio Gonzalez, MD
- 전화번호: 4133869415
- 이메일: Antonio.Gonzalez-fiol@yale.edu
연구 장소
-
-
Connecticut
-
New Haven, Connecticut, 미국, 06510
- Yale University
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- ASA-1, ASA-2, and ASA-3
- Patients with no known back deformities
- Ability to sit upright for epidural placement
- No prior lumbar surgery
- No allergies to ultrasound gel
Exclusion Criteria:
- Coagulopathy
- Low platelet count
- Allergies to local anesthetics
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 다른
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 더블
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
활성 비교기: Handheld traditional ultrasound
Traditional US will be used to compare number of needle manipulations to the handheld US. |
Labor epidural will be performed after marking patient skin using traditional ultrasound guidance |
|
다른: Handheld Automated ultrasound
Automated device provides automatic information pertaining to distance to epidural space distance and interspace location. |
Labor epidural will be performed after marking patient skin using an automated ultrasound device |
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Number of needle passes
기간: From local anesthetic injection (time 0) till Loss of resistance (in minutes), up to 60 minutes
|
Number of ventral needle movements without removing needle from skin. A needle pass is defined as any forward advancement or withdraw and forward redirection of the needle without withdraw from the skin. |
From local anesthetic injection (time 0) till Loss of resistance (in minutes), up to 60 minutes
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Number of Needle attempts
기간: From local anesthetic injection (time 0) till Loss of resistance (in minutes), up to 60 minutes
|
Number of times the needle is advanced in and out of the skin |
From local anesthetic injection (time 0) till Loss of resistance (in minutes), up to 60 minutes
|
|
Time to obtain ultrasound images with traditional ultrasound device
기간: Time at which ultrasound device is placed on patients back (time 0) until image obtained (in minutes), up to 30 minutes
|
Time from placing ultrasound on patients back until markings are complete |
Time at which ultrasound device is placed on patients back (time 0) until image obtained (in minutes), up to 30 minutes
|
|
Time to obtain images with automated ultrasound device
기간: Time at which ultrasound device is placed on patients back (time 0) until image obtained (in minutes), up to 30 minutes
|
Time from placing ultrasound on patients back until markings are complete |
Time at which ultrasound device is placed on patients back (time 0) until image obtained (in minutes), up to 30 minutes
|
|
Time from local anesthetic injection till time of epidural space identification
기간: Up to 60 minutes
|
Time will be recorded once local anesthetic is injected and stopped upon obtaining loss of resistance |
Up to 60 minutes
|
|
Accuracy of handheld ultrasound - difference between predicted epidural space distance minus actual needle distance
기간: Up to 60 minutes
|
Accuracy will equal the difference between the estimated depth calculated by the device - actual needle depth as measured from skin to epidural space in centimeters. |
Up to 60 minutes
|
|
Accuracy of automated ultrasound device - difference between predicted epidural space distance minus actual needle distance
기간: Up to 60 minutes
|
Accuracy will equal the difference between the estimated depth calculated by the device - actual needle depth as measured from skin to epidural space in centimeters. |
Up to 60 minutes
|
|
Patient satisfaction
기간: 15 - 20 minutes after epidural placement
|
Assessed after the administration of the loading dose. Patient will be asked to rate their pain on a scale 0-10, 0 = not satisfied, 10 = completely satisfied |
15 - 20 minutes after epidural placement
|
공동 작업자 및 조사자
스폰서
수사관
- 수석 연구원: Antonio Gonzalez, MD, Yale University
간행물 및 유용한 링크
일반 간행물
- Vallejo MC, Phelps AL, Singh S, Orebaugh SL, Sah N. Ultrasound decreases the failed labor epidural rate in resident trainees. Int J Obstet Anesth. 2010 Oct;19(4):373-8. doi: 10.1016/j.ijoa.2010.04.002. Epub 2010 Aug 8.
- Carvalho B, Seligman KM, Weiniger CF. The comparative accuracy of a handheld and console ultrasound device for neuraxial depth and landmark assessment. Int J Obstet Anesth. 2019 Aug;39:68-73. doi: 10.1016/j.ijoa.2019.01.004. Epub 2019 Jan 11.
- Weiniger CF, Carvalho B, Ronel I, Greenberger C, Aptekman B, Almog O, Kagan G, Shalev S. A randomized trial to investigate needle redirections/re-insertions using a handheld ultrasound device versus traditional palpation for spinal anesthesia in obese women undergoing cesarean delivery. Int J Obstet Anesth. 2022 Feb;49:103229. doi: 10.1016/j.ijoa.2021.103229. Epub 2021 Sep 23.
- Seligman KM, Weiniger CF, Carvalho B. The Accuracy of a Handheld Ultrasound Device for Neuraxial Depth and Landmark Assessment: A Prospective Cohort Trial. Anesth Analg. 2018 Jun;126(6):1995-1998. doi: 10.1213/ANE.0000000000002407.
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- 2000034863
- No NIH funding 09.05.23 (기타 식별자: Yale)
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
미국에서 제조되어 미국에서 수출되는 제품
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .