5 Years Long Term Results After Standalone CyPass-Implantation
Retro- and Prospective Monocentric Study to Evaluate the Safety and Effectiveness of the CyPass Stent 5 Years After Implantation
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Szczegółowy opis
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Mecklenburg/Vorpommern
-
Neubrandenburg, Mecklenburg/Vorpommern, Niemcy, 17036
- Dietrich-Bonhoeffer-Klinikum
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dziecko
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- patients who have undergone a standalone cypass implantation at least 3 years ago
- signed inform consent
Exclusion Criteria:
- Patients with too much travel distance between study center and home
- Patients who cannot visit the studycenter due to health problems
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Liczba grup / kohort
Kohorty i interwencje
Grupa / KohortaGrupa / Kohorta |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
standalone CyPass implantation
patients who have undergone a standalone cypass implantation without cataract surgery more than 3 years ago
|
Heidelberg Retinal Topography, Visual field, intraocular pressure, medication anamnesis, Retinal Nerve Fibre Layer Thickness, Pachymetry, Sonography, full ophthalmological examination
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Number of Patients That Achieve Target Intraocular Pressure Measured in mmHg
Ramy czasowe: up to 7 years
|
The Measurement of the intraocular Pressure is a criterion for the Efficacy of CyPass Stent Procedure (success rate).
The postoperative target pressure of 15 mmHg, 18 mmHg or 21 mmHg (depends on Glaucoma Status) has to be achieved.
|
up to 7 years
|
|
Change of Intraocular Pressure in mmHg Preoperatively (at Screening) vs Postoperatively (at Final Examination)
Ramy czasowe: up to 7 years
|
The Measurement of the intraocular Pressure change is a criterion for the Efficacy of CyPass Stent Procedure (success rate). The postoperative pressure after 5 to 7 years has to be compared with the preoperative intraocular pressure (in mmHg) The change was calculated only from two time points. (value at the final examination time point minus the value at the preoperative time point |
up to 7 years
|
|
Number of Additional Medication
Ramy czasowe: up to 7 years
|
The number of additional Glaucoma medication is another criterion to determine the Efficacy of CyPass Stent Procedure (success rate). Up to 4 different active substance can be used to reduce the pressure. The more substances the patient uses postoperatively the lower is the success after implantation of the CyPass-Stent. The postoperative number of medications after 5 years has to be compared with the preoperative number |
up to 7 years
|
|
Number of Participants With Secondary Glaucoma Procedures
Ramy czasowe: up to 7 years
|
To determine the efficacy of CyPass Stent procedure completely the number of secondary glaucoma interventions (surgery/ laser) has to be documented
|
up to 7 years
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Number of Participants With Stability of Optic Nerve
Ramy czasowe: up to 7 years
|
The Measurement of the optic nerve (HRT) in comparison to the baseline is needed to evaluate the glaucoma damage and to determine the Longterm success rate and the safety of the CyPass- Stent-Procedure. With papillary tomography you can see the changes in the optic nerve head concerning the permanent failures of retinal vessels , measure them very precisely and compare them with the previous findings. |
up to 7 years
|
|
Number of Participants With Stability of the Retinal Nerve Fiber Layer Thickness
Ramy czasowe: up to 7 years
|
The comparison of the preoperative and postoperative Status of the Retinal Nerve Fiber Layer Thickness and retinal fundus thickness is another criterion to determine the absolute and relative success.
|
up to 7 years
|
|
Number of Participants With Stability of Visual Field
Ramy czasowe: up to 7 years
|
The parameter of the Visual Field (Mean Deviation) will be measured to evaluate the Safety of the CyPass-Procedure.
The visual Field shows the progression of glaucoma defects concerning failures in different parts for example in the center or in the periphery of the visual field.
|
up to 7 years
|
|
Number of Participants With Stability of Stent Position
Ramy czasowe: up to 7 years
|
Determination of Stent Position in the angle will be performed to exclude moving of the Stent.
The stent could change it's position forward into the anterior chamber or backwards in the suprachorioidal space
|
up to 7 years
|
|
Number of Participants With Stability of Stent Tissue Interaction
Ramy czasowe: up to 7 years
|
Determination of iris tissue reaction to the stent will be performed.
We document slight reaction without involving the opening, iris reaction with involving the opening and complete closure by tissue.
The iris Tissue could overgrow the opening of the stent and therfore the function of the stent is disturbed or even failed.
|
up to 7 years
|
|
Number of Participants With Intra-and Postoperative Complications
Ramy czasowe: up to 7 years
|
The number of intra-and postoperative complications are needed to evaluate the safety of the CyPass-procedure
|
up to 7 years
|
|
Number of Participants With Suprachoroidal Bleb
Ramy czasowe: up to 7 years
|
The Determination of the suprachoroidal bleb is needed to evaluate the function of the stent and the efficacy of the procedure.
The bigger the bleb, the lower the pressure and the better the efficacy of the stent
|
up to 7 years
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Główny śledczy: Helmut Hoeh, MD,FEBO, Department of Ophthalmology, Neubrandenburg, Germany
Publikacje i pomocne linki
Publikacje ogólne
- Garcia-Feijoo J, Rau M, Grisanti S, Grisanti S, Hoh H, Erb C, Guguchkova P, Ahmed I, Grabner G, Reitsamer H, Shaarawy T, Ianchulev T. Supraciliary Micro-stent Implantation for Open-Angle Glaucoma Failing Topical Therapy: 1-Year Results of a Multicenter Study. Am J Ophthalmol. 2015 Jun;159(6):1075-1081.e1. doi: 10.1016/j.ajo.2015.02.018. Epub 2015 Mar 3.
- Hoeh H, Vold SD, Ahmed IK, Anton A, Rau M, Singh K, Chang DF, Shingleton BJ, Ianchulev T. Initial Clinical Experience With the CyPass Micro-Stent: Safety and Surgical Outcomes of a Novel Supraciliary Microstent. J Glaucoma. 2016 Jan;25(1):106-12. doi: 10.1097/IJG.0000000000000134.
- Grisanti S, Margolina E, Hoeh H, Rau M, Erb C, Kersten-Gomez I, Dick HB, Grisanti S. [Supraciliary microstent for open-angle glaucoma: clinical results of a prospective multicenter study]. Ophthalmologe. 2014 Jun;111(6):548-52. doi: 10.1007/s00347-013-2927-6. German.
- Hoh H, Grisanti S, Grisanti S, Rau M, Ianchulev S. Two-year clinical experience with the CyPass micro-stent: safety and surgical outcomes of a novel supraciliary micro-stent. Klin Monbl Augenheilkd. 2014 Apr;231(4):377-81. doi: 10.1055/s-0034-1368214. Epub 2014 Apr 25.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- STI 06/16
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Opis planu IPD
Ramy czasowe udostępniania IPD
Kryteria dostępu do udostępniania IPD
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Glaucoma diagnostics
-
NCT02266459Zakończony
-
NCT06111391ZakończonyZadowolenie pacjenta | Wyniki kliniczne | Powikłanie protetyczne
-
NCT02522273WycofanePomiar mleczanu we krwi płodu
-
NCT03146013ZakończonyInfekcje HTLV-I | Infekcje HTLV-II | Ludzki wirus T-limfotropowy 1 | Ludzki wirus T-limfotropowy 2 | Chłoniak białaczkowy związany z HTLV I | Mielopatie związane z HTLV I
-
NCT03226119ZakończonyInfekcje HTLV-I | Infekcje HTLV-II | Ludzki wirus T-limfotropowy 1 | Ludzki wirus T-limfotropowy 2 | Chłoniak białaczkowy związany z HTLV I | Mielopatie związane z HTLV I
-
NCT02905786Zakończony
-
NCT03814096WycofaneKiła wrodzona | Kiła matki w czasie ciąży – dziecko jeszcze nie urodzone
-
NCT04889365Aktywny, nie rekrutującyZakażenie SARS-CoV2
-
NCT03105609ZakończonyZwyrodnienie plamki żółtej | Neowaskularyzacja naczyniówkowa
-
NCT05354804Zakończony