Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Keratometric Tear Breakup Time and Fluorescein Tear Breakup Time

22 oktober 2014 uppdaterad av: University of Arkansas

Comparison of Keratometric Tear Break Up Time (KTBUT) to Fluorescein Tear Break Up Time (FTBUT)

The purpose of the research is to determine if putting fluorescein onto the eye (most common test done for dry eye syndrome) is an accurate way to measure dry eye symptoms. The investigators can avoid placing any foreign substance into the eye by using a manual keratometer. Therefore, the investigators want to compare the measurements of tear breakup time using fluorescein with using a novel method, a manual keratometer and then compare these measurements to a validated dry eye symptoms questionnaire. All qualifying patients who were scheduled in the Jones Eye Institute Clinics for a complete eye exam were offered information about the study and invited to participate. Participants were recruited from February 29, 2009 to April 14, 2009.Participants who did not meet the study protocol's inclusion and exclusion criteria were not included the study or study data analysis. All subjects eyes were measured for KTBUT and FTBUT.

Studieöversikt

Status

Avslutad

Betingelser

Detaljerad beskrivning

This is an observational study to measure the difference between Keratometric Tear Break Up Time (KTBUT) and Fluorescein Tear Break Up Time (FTBUT). All qualified study participants had their eyes measured for tear break up time measured with a keratometer and with fluorescein dye. In this study, we compare the use of the most common method, fluorescein dye, to measure tear break up time to a novel method, a keratometer, to measure tear break up time. Using the keratometer avoids instilling fluorescein dye into the tear film and not altering the tear film's physiologic environment.

Studietyp

Observationell

Inskrivning (Faktisk)

26

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

    • Arkansas
      • Little Rock, Arkansas, Förenta staterna, 72205
        • Jones Eye Institute, University of Arkansas for Medical Sciences

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

18 år och äldre (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Nej

Kön som är behöriga för studier

Allt

Testmetod

Icke-sannolikhetsprov

Studera befolkning

Patients from the Jones Eye Clinic, Department of Ophthalmology, University of Arkansas for Medical Sciences

Beskrivning

Inclusion Criteria:

  • An adult, between ages 18-99
  • An adult who is able to understand study instructions

Exclusion Criteria:

  • An adult with corneal pathology that prevents accurate assessment of keratometric or fluorescein tear break up time.
  • An adult with an allergy to fluorescein, a very common eye dye that detects defects in the cornea.
  • The inability to answer questions on your own.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Observationsmodeller: Endast fall
  • Tidsperspektiv: Blivande

Kohorter och interventioner

Grupp / Kohort
Keratometric Tear Breakup Time
These are the study participants whose tear break up times were measured with a keratometer.
Fluorescein Break Up Time
These are the study participants whose tear break up times were measured with with fluorescein dye.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Difference Between Keratometric Tear Break Up Time (KTBUT) and Fluorescein Tear Break Up Time (FTBUT)
Tidsram: 1 day
This outcome measures the difference in tear break up time using a keratometer and fluorescein dye.
1 day

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Ocular Surface Disease Index (OSDI) Questionnaire
Tidsram: 1 week
The Ocular Surface Disease Index (OSDI) is a validated 12-item questionnaire used in dry eye studies. The OSDI Scale ranges from 0= Normal to 100= Severe. Subcategories include problems--all of the time, most of the time, half of the time,and none of the time.
1 week

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart

1 februari 2009

Primärt slutförande (Faktisk)

1 juni 2009

Avslutad studie (Faktisk)

1 juni 2009

Studieregistreringsdatum

Först inskickad

2 mars 2009

Först inskickad som uppfyllde QC-kriterierna

2 mars 2009

Första postat (Uppskatta)

3 mars 2009

Uppdateringar av studier

Senaste uppdatering publicerad (Uppskatta)

23 oktober 2014

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

22 oktober 2014

Senast verifierad

1 oktober 2014

Mer information

Termer relaterade till denna studie

Ytterligare relevanta MeSH-villkor

Andra studie-ID-nummer

  • 109338

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Kliniska prövningar på Torra ögon

3
Prenumerera