Development of an Acceleration Based Fall Risk Detector (field)

July 26, 2010 updated by: Maastricht University Medical Center

Because the increasing fall problem, mainly due to an impaired gait and balance ability, this study will investigate fall risk by detecting fall related movement characteristics. Based on the promising results using accelerometry for accurate and objective gait analysis, fall risk will be measured using a triaxial accelerometer.

At the moment our group is performing a study titled 'identify subjects at risk for falling using accelerometry'. In this study, fall related movement characteristics (gait, balance, stumble reaction) are identified in healthy younger and older subjects under standardised laboratory circumstances. In this way, specific characteristics can be selected which are responsible for fall risk.

The aim of this study is investigating if the acceleration based fall risk detector can be applied in daily life with target groups.

Study Overview

Status

Unknown

Conditions

Intervention / Treatment

Detailed Description

A first step to field measurement with target group is the measurement of elderly with a certain fall risk in a simple field condition like a nursing home.

First fall risk is assessed in elderly using the Tinetti scale (score between 19-24) which is the gold standard for fall risk assessment . This scale consist of a gait and balance score. Only subjects who have a fall risk are included for further measurements.

  1. A gait test will be performed to analyze movement parameters. Subjects have to walk 6 times a 20 meter distance at preferred speed while a small (56mmx61mmx15mm), light weight (5g) and ambulant accelerometer is attached on the sacrum with an elastic belt. The accelerometer measures accelerations of the body in three directions (antero-posterior, media-lateral and cranial-caudal) with a sample frequency of 100Hz.
  2. The balance ability will be tested by performing 4 balance tasks while the same accelerometer measures the movements of the body. Subjects have to stand with feet closed on a normal or foam surface while having the eyes open and closed.
  3. The Get Up and Go test is performed: subjects start in sitting position, have to rise, walk 3m, turn around, walk back and sit again. The time needed to perform this test is measured.
  4. 20 subjects (remaining in Scharweyerveld and Zorgboog) are monitored for one day and 20 elderly women (>70y) (recruited at the F&O policlinic MUMC)are measured for 5 successive days, to investigate the mobility and more fall related movement parameters. The accelerometer is attached to the sacrum in the morning. First the other 2 measurements are performed, and then subjects wear the device during the whole day. The accelerometer is small, light and ambulant which is not interfering with daily activities. Subjects have to keep a diary to note all activities performed during that day. THis will be used to explain the acceleration signal.

For the subject recruited from the F&O poli, a fall diary is kept for one year were subjects have to note when a fall has happened. In addition muscle strength in measured in this population and a questionnaire concerning quality of life (Euroqol) is completed in this group.

All acceleration data will be analyzed using specific algorithms programmed in Matlab(c). Statistical analysis will be performed in SPSS using pearson correlation to investigate correlations between gait parameters, balance characteristics and the ability perform the Get Up and Go test. Pearson correlation will also be used to validate the objective gait and balance test with the Tinetti scale. Differences in function tests between elderly at risk (measured in this study) and healthy subjects (measured in a previous study under lab conditions) will be investigated using ANOVA (p< 0.005).

Study Type

Interventional

Enrollment (Anticipated)

100

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

65 years to 90 years (Older Adult)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Having a fall risk (Tinetti score between 19-24)
  • Men and women older than 65 years at risk for falling - able to walk without walking aids - voluntary and willing to participate
  • Fully competent

Exclusion Criteria:

  • Unable to walk
  • Denying
  • Very high fall risk (Tinetti score < 19)

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Prevention
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: 1
subjects with fall risk
fall risk detector: stumbles, specific fall related movements, falls

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
Acceleration based movement characteristics
Time Frame: 1 day
1 day

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Study Chair: kenneth Meijer, UD, University Maastricht

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

August 1, 2008

Primary Completion (Anticipated)

October 1, 2010

Study Completion (Anticipated)

October 1, 2010

Study Registration Dates

First Submitted

October 1, 2008

First Submitted That Met QC Criteria

October 6, 2008

First Posted (Estimate)

October 7, 2008

Study Record Updates

Last Update Posted (Estimate)

July 27, 2010

Last Update Submitted That Met QC Criteria

July 26, 2010

Last Verified

July 1, 2010

More Information

Terms related to this study

Other Study ID Numbers

  • MEC 08-3-042
  • ABR 22858/NL22858.068.08

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Fall Risk

Clinical Trials on fall risk detector

3