Iron Status and Cardiopulmonary Physiology

October 16, 2018 updated by: Lieutenant Colonel David Holdsworth, Royal Centre for Defence Medicine

Effects of Iron Status, Manipulated Using Intravenous Iron, on Cardiopulmonary Physiology During Ascent to Very High Altitude

This study involved human volunteers undertaking a high-altitude expedition. It assessed changes in physiological parameters of relevance to high-altitude cardiopulmonary physiology. Participants included a subgroup of those taking part in an existing adventurous training expedition and were randomised in a 1:1 fashion to receive either intravenous iron or normal saline several weeks prior to departure. During the expedition, participants were investigated by means of transthoracic echocardiography, peripheral oxygen saturation measurement and heart rate monitoring and through the drawing of venous blood samples. Bloods were later analysed for markers of iron status.

Study Overview

Detailed Description

Aim

The aim of the study was to investigate the effects of iron status on human cardiopulmonary physiology during ascent to very high altitude. Differences in iron status were brought about using intravenous iron, and outcomes were assessed using echocardiography and self-reported functional performance scores.

Objectives

Principal objective: To compare echocardiographic parameters in individuals of differing iron status during the expedition.

Secondary objectives: To compare physiological variables (oxygen saturation, pulse) and self-reported functional measures, in individuals of differing iron status during the expedition.

Hypotheses

The primary hypothesis was that iron status, manipulated using intravenous iron, would influence the echocardiographic indices of cardiopulmonary physiological function over the course of the ascent.

A secondary hypothesis was that iron status would influence cardiopulmonary responses in terms of pulse and oxygen saturation, and additionally the perceived exertion involved in ascent to very high altitude.

Design of the Study

The study randomised 18 individuals to iron or normal saline in a 1:1 ratio giving two groups of 9 people. The randomised infusion (control or iron) was undertaken at a pre-expedition meeting approximately 2 weeks prior to the flight to Nepal. The profile of ascent to high altitude will followed internationally accepted acclimatisation guidelines.

Preliminary Testing

To exclude elevated iron stores prior to enrollment, participants underwent an initial blood test. At the pre-exercise mounting station, prior to the flight to Nepal, baseline echocardiography was performed, and blood samples were collected immediately prior to randomisation and infusion. All blood samples in the study were analysed for full blood count, ferritin, iron, transferrin and C-reactive protein (CRP).

Expedition-based tests

Waking peripheral oxygen saturation (%) of haemoglobin (SpO2) and pulse were recorded daily. Venous blood samples were taken for later analysis of variables relevant to iron homeostasis including full blood count, erythropoietin, soluble transferrin receptor and hepcidin. These samples were taken in Kathmandu on the morning following arrival, at the intermediate staging camp (~3,200m) and then at the Dhaulagiri base camp on arrival and after descents from 6,000m and 7,000m.

Measures of both left and right heart function were performed and included: pulmonary artery systolic pressure, pulmonary acceleration time, pulmonary regurgitation end diastolic velocity and tricuspid annular plane systolic excursion (distance of systolic excursion of the right ventricular annular plane towards the apex - TAPSE). Echo parameters were acquired and processed by an appropriately experienced researcher. Measures were taken during exercise on arrival at each test altitude and at rest the following morning. Measurements taken from climbers returning from either 6,000 m or 7,000 m were taken as soon as possible after their return to base camp.

Subjective ratings scales include those for breathlessness (Borg 1-10) and perceived exertion (Borg 6-20).

Blood sample storage and analysis

Once drawn, venous blood was placed on ice. Following centrifugation (3,500 rpm for 10 minutes at 4OC), aliquots of plasma were stored in cryogenic vials at -20°C. Samples drawn at high altitude were transported on dry ice or in liquid nitrogen 'dry-shippers' (safe liquid nitrogen containers that cannot leak nitrogen as liquid) back to the UK (United Kingdom). Subsequent analysis was performed at the University of Oxford.

Statistical analysis

Data were analysed using statistical tests with International Business Machines (IBM) 'statistical package for social sciences' (SPSS) version 22 software.

Study Type

Interventional

Enrollment (Actual)

18

Phase

  • Not Applicable

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 55 years (Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Healthy non-pregnant adults
  • Age 18-55 years
  • Serving in the UK Armed Forces
  • Selected for a military mountaineering team intending to climb to very high altitude

Exclusion Criteria:

  • Diabetes
  • Any cardiovascular or respiratory illness
  • Regular medication which would interfere with any outcome measures in the study
  • Pregnancy
  • Any condition which precludes the administration of Ferinject:

    (i) hypersensitivity to the active substance, to Ferinject® or any of its excipients (ii) known serious hypersensitivity to other parenteral iron products (iii) microcytic anaemia not attributable to iron deficiency (e.g. sickle cell anaemia) (iv) evidence of iron overload or disturbances in the utilisation of iron.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Basic Science
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Triple

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Iron
Received a blinded single 15 mg/kg dose of iv ferric carboxymaltose (Ferinject) up to a maximum off 1g total dose 2 weeks prior to ascent to very high-altitude.
iv iron infusion: 15 mg / kg up to a maximum 1g dose of Ferinject diluted in normal saline (0.9%) up to a total volume of 250 ml
Other Names:
  • Ferinject
Sham Comparator: Saline control
Received a blinded single dose of iv normal saline 2 weeks prior to ascent to very high-altitude.
250 ml of normal (0.9%) saline given by intravenous infusion over 20 minutes. This constitutes the control for the iron infusion.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Change in right ventricular systolic pressure (RVSP) with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Non-invasive measurement of Right ventricular systolic pressure (mmHg) estimated from the velocity of tricuspid regurgitation (TR) (m/s) measured during transthoracic echocardiographic (TTE) continuous wave (CW) Doppler assessment of the tricuspid valve regurgitant jet (RVSP = TR velocity^2 * 4)
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in time from pulmonary valve opening to peak pulmonary flow velocity with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
The time from pulmonary valve opening to peak velocity flow is inversely correlated with pulmonary artery pressure. This time is measured on a pulsed wave (PW) Doppler trace in the parasternal short axis view at the pulmonary valve level. The measurement is a time and the units are ms. Categories are: normal (>130 ms), borderline elevated (100-130 ms), elevated (80-100 ms) and severely elevated (<80 ms).
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in left ventricular stroke volume (LV SV) with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
The stroke volume of the left ventricle is calculated from 2-D parasternal echocardiographic measurement of the left ventricular outflow tract diameter (LVOT) and pulsed wave (PW) Doppler measurement of the flow through the LVOT during systole. PW of the LVOT allows measurement of the velocity.time integral of the LVOT flow (VTI). This value, when multiplied by the cross sectional area of the LVOT, allows an extimate of stroke volume. SV = (Pi*(radius of LVOT^2))*VTI of LVOT
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in left ventricular index of myocardial performance (LIMP) with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
This is a non-invasive measurement of left ventricular function made by transthoracic echocardiography (TTE). Tissue Doppler imaging (TDI) is used to measure the behaviour of the left ventricle throughout the cardiac cycle (both systole and diastole). This allows the time (ms) of isovolumic contraction time (ICT), isovolumic relaxation time (IVRT) and ejection time (ET). The LIMP (also known as Tei index) = IVCT+IVRT/ET. It is a global measure of systolic and diastolic function of the heart.
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in right ventricular index of myocardial performance (RIMP) with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
This is a non-invasive measurement of right ventricular function made by transthoracic echocardiography (TTE). Tissue Doppler imaging (TDI) is used to measure the behaviour of the left ventricle throughout the cardiac cycle (both systole and diastole). This allows the time (ms) of isovolumic contraction time (ICT), isovolumic relaxation time (IVRT) and ejection time (ET). The RIMP = IVCT+IVRT/ET. It is a global measure of systolic and diastolic function of the heart.
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in tissue Doppler velocity of the Right Ventricle (RV) and Left Ventricle (LV); units: cm/s, with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Tissue Doppler imaging (TDI) is performed on the ventricular myocardium 1cm apical to the atrioventricular valve annulus (either the tricuspid valve annulus, for the RV assessment, or the LV septum and LV lateral wall adjacent to the mitral valve for the LV assessment). The parameters are peak systolic velocity (s', cm/s), peak velocity during early diastole (e', cm/s) and peak velocity during atrial systole (a', cm/s).
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in tricuspid annulus planar systolic excursion (TAPSE) with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
This is a Doppler M-mode measurement of the full range of movement of the tricuspid annulus at the right ventricular (RV) free wall throughout the cardiac cycle. It is measured by placing an M-mode cursor through the connection of the tricuspid annulus to the RV free wall and measuring the basal-apical excursion of the annulus at this point, from end diastole until the most apical point that it reaches in systole. It is a measure of systolic RV function. Its units are cm.
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in right and left ventricular strain with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Non-invasive tissue Doppler measurements are acquired on apical 4-chamber, apical 2-chamber and apical 3-chamber images throughout 3 cardiac cycles to allow later analysis to determine the longitudinal strain of the right and left ventricle
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Change in peripheral oxygen saturation with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Peripheral oxygen saturation measured using a non-invasive portable, fingertip pulse oximeter
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in heart rate with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Heart rate measured by 3 lead ECG monitor connected to a portable transthoracic echocardiography machine
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in blood ferritin level (ug/L) with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Venous blood samples analysed for ferritin
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in haemoglobin level (g/dL) with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Venous blood samples analysed for haemoglobin
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in transferrin saturation (%) with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Venous blood samples analysed for transferrin and iron to allow the calculation of the transferrin saturation, listed as a percentage
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in soluble transferrin receptor level (nmol/L) with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Venous blood samples analysed for soluble transferrin receptor
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Change in hepcidin level (ng/mL) with altitude
Time Frame: Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)
Venous blood samples analysed for hepcidin
Measurement performed at baseline (2 weeks prior to commencing ascent to very high altitude) and at intervals during ascent to very high altitude (over a period of 2 weeks)

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

January 19, 2016

Primary Completion (Actual)

May 1, 2016

Study Completion (Actual)

December 7, 2017

Study Registration Dates

First Submitted

October 1, 2018

First Submitted That Met QC Criteria

October 5, 2018

First Posted (Actual)

October 16, 2018

Study Record Updates

Last Update Posted (Actual)

October 18, 2018

Last Update Submitted That Met QC Criteria

October 16, 2018

Last Verified

October 1, 2018

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

No

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Iron-deficiency

Clinical Trials on Ferric Carboxymaltose Injectable Product

3