Validation and Feasibility in Clinical Practice and Concordance of an Automated System Coupling an RGB-D Camera and a Software Based on Artificial Intelligence for the Measurement of Shoulder Range of Motion for Patients Operated on a Total Reversed Shoulder Prosthesis.

March 14, 2022 updated by: Centre Hospitalier Universitaire de Nice

Validation and Feasibility in Clinical Practice and Concordance of an Automated System Coupling an RGB-D Camera and the ShoulderROM, an Artificial Intelligence -Based Software, for the Measurement of Shoulder Range of Motion for Patients Operated on a Total Reversed Shoulder Prosthesis.

The functional evaluation of the shoulder, which is the most mobile joint in the human body, is a complex clinical examination to perform. The mobility of the shoulder is based on a three-dimensional mobility cone, which is difficult to represent and measure. However, an accurate and reliable measurement of the shoulder's articular amplitude is fundamental for its functional evaluation. Indeed, these measurements contribute to determine the global management strategy of the patient and the follow-up of its evolution.

The conventional method of measuring shoulder joint amplitudes involves the use of a goniometer. Nevertheless, visual estimation is the most used in consultation but is limited by its very examiner-dependent character.

Technological advances have allowed the development and deployment of additional tools in the clinical setting, with the goal of simplifying, reducing measurement bias, and standardizing joint range of motion (ROM) measurement techniques.

Our team has recently published a study to validate the use of a joint ROM measurement system, coupling a RGB-D (Red Green Blue - Depth) sensor and an artificial intelligence (AI) algorithm, on volunteer subjects with no shoulder history. The RGB-D camera is a technological tool in high development and low cost. It consists of two sensors, an infrared projector and an RGB module. The camera simultaneously provides a two-dimensional (2D) image and its environment by creating a color flow using infrared technology combined with a depth map characterizing the distance of objects seen in the image. The AI algorithm then automatically detects a 2D skeleton that identifies the main joints of the upper limb (shoulder, elbow, wrist) and the trunk axis. Then, the angle of interest is measured and each mobility is automatically measured in 3D by the algorithm.

The main objective of the study is to validate and demonstrate the feasibility in clinical practice and the concordance of an automated RGB-D + AI system for the measurement of shoulder joint ROMs of patients having undergone reverse total shoulder replacement surgery. These measurements will be compared with the visual method and the goniometer, that are measurements made in normal care routine. The ROM measures obtained by means of the RGB-D + AI system will be compared to those obtained in clinical practice during the annual follow-up visit in normal care routine. The main evaluation criterion is the measurement of joint amplitude measured in degrees [°]. The ROMs that will be measured are those normally assessed in clinical practice: abduction-adduction, flexion-extension and external-internal rotation elbow to body or at 90°.

This study aims also at observing and comparing the postoperative joint ROM measurements estimated in the preoperative planning phase by the Blue-Print software with the actual postoperative ROM measured with the RGB-D + AI system.

The study is observational. The processing of the collected data does not foresee any intervention on the patient or modification of the surgeon's choice concerning the management of the patient. It is indeed a RNIPH (Recherche non impliquant la personne humaine).

Study Overview

Status

Recruiting

Intervention / Treatment

Study Type

Observational

Enrollment (Anticipated)

50

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

      • Nice, France, 06003
        • Recruiting
        • CHU de Nice
        • Contact:

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 90 years (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

Male

Sampling Method

Non-Probability Sample

Study Population

Patients who have received a reverse total shoulder arthroplasty with more than 2 years of follow-up.

Description

Inclusion Criteria:

  • Male or female, age ≥ 18 years old.
  • Patient having undergone a total reversed shoulder prosthesis in the department of Orthopedic Surgery of the CHU of Nice - Pasteur Hospital with at least two years of follow-up.

Exclusion Criteria:

  • patient Not take in charge in the CHU of Nice
  • Patient without 2 years of follow-up

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Observational Models: Case-Only
  • Time Perspectives: Other

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
Reverse total shoulder arthroplasty
Patients who have received a reverse total shoulder arthroplasty with more than 2 years of follow-up in a temporal frame going from 2016 to 2022.
range of motion (in degrees) measured in annual postoperative follow-up

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
range of motion (in degrees) measured in annual postoperative follow-up consultation by visual measurement, goniometer and RGB-D + AI system
Time Frame: 2016-2022

'The main evaluation criterion is the measurement of joint amplitude measured in degrees [°].

The ranges that will be measured are those normally assessed in clinical practice: abduction-adduction, flexion-extension and external-internal rotation elbow close to body or at 90°.

2016-2022

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
range of motion (in degrees) estimated in preoperative planning with the BluePrint software
Time Frame: 2016-2022
'Joint range of postoperative joint range of motion measurements estimated in the preoperative planning phase by the Blue-Print software is compared with the actual postoperative range of motion observed with the system system RGB-D+IA
2016-2022

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

January 1, 2022

Primary Completion (Anticipated)

May 1, 2022

Study Completion (Anticipated)

May 31, 2022

Study Registration Dates

First Submitted

March 14, 2022

First Submitted That Met QC Criteria

March 14, 2022

First Posted (Actual)

March 23, 2022

Study Record Updates

Last Update Posted (Actual)

March 23, 2022

Last Update Submitted That Met QC Criteria

March 14, 2022

Last Verified

March 1, 2022

More Information

Terms related to this study

Keywords

Other Study ID Numbers

  • 22Chirortho01

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

No

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Arthroplasty Complications

Clinical Trials on shoulder arthroplasty

3
Subscribe