Radiologic Pathologic Correlation of Imaging to Distinguish True Progression From Pseudoprogression in Brain Malignancies

December 29, 2023 updated by: M.D. Anderson Cancer Center
To learn if advanced imaging methods can tell apart true progression (the disease has actually gotten worse) from pseudoprogression (the disease appears to have gotten worse, but it actually has not).

Study Overview

Detailed Description

Primary Objectives To determine if advanced imaging findings can correlate with tissue changes in order to distinguish true progression from pseudoprogression. We will recruit participants with new suspicious enhancement developing during treatment for glioma, and systematically perform: a) high quality routine MR imaging (including routine, diffusion, permeability, perfusion and spectroscopy imaging as part of our regular ABTI protocol) and compare this imaging to b) pathology obtained by means of stereotactic biopsy. Pathology will serve as the gold standard to determine which imaging strategies are most successful in distinguishing between true Tumor recurrence and Pseudoprogression for each lesion.

Secondary Objectives

  1. To assess the feasibility of Contrast Clearance MR (delayed T1 enhanced MR) subtraction maps in distinguishing Pseudoprogression from true progression.
  2. To gather observational data for Dual Energy CT imaging and delayed contrast clearance with Dual Energy CT in the assessment of glioma.
  3. To correlate quantitative imaging biomarkers (derived from MR imaging data) along the biopsy tract with histological and clinical biomarkers. This exploratory data could generate novel comparisons to determine those imaging biomarkers that are most effective at predicting (a) cellular density and, (b) the types and relative numbers of cells present in the brain.
  4. To observe clinical outcomes such as progression free survival and overall survival in the trial population and relate these to imaging findings.

Study Type

Interventional

Enrollment (Estimated)

25

Phase

  • Phase 1

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  1. Participants is >18 years old. The pediatric population has a different disease profile from adult glioma participants. To reduce heterogeneity in the patient population we will not consider participants younger than 18 for this study.
  2. The participants agrees to participate in the clinical study and to complete all required visits and evaluations.
  3. Participants has undergone prior treatment for a brain tumor and has a new suspicious imaging finding requiring diagnostic workup and is being considered for biopsy.
  4. Participants agrees to undergo, prior to the procedure, the needed imaging evaluation (within 14 days and preferably with 3 days of the planned procedure).

Exclusion Criteria:

  1. Renal failure as evidenced by a GFR of less than 30 mL/min/1.73m2 for gadolinium based imaging. In the absence of eGFR lab result, participants is not excluded in the absence of remarkable pathological renal history, as confirmed by and in the discretion of the PI.
  2. For iodinated contrast agent we will use the more strict cut-off of 45 mL/min/1.73m2 ((Davenport, Perazella et al. 2020), Consensus statement from the ACR and the National Kidney Foundation). The different threshold reflects the different risk profiles of these agents. Participants with GFR in the range 30-45 can receive a Non-Contrast DECT (CT contrast withheld).
  3. Pacemakers, electronic stimulation, metallic foreign bodies and devices and/or other conditions that are not MR safe, which include but are not limited to:

    • electronically, magnetically, and mechanically activated implants
    • ferromagnetic or electronically operated active devices like automatic cardioverter defibrillators and cardiac pacemakers
    • metallic splinters in the eye
    • ferromagnetic hemostatic clips in the central nervous system (CNS) or body
    • cochlear implants
    • other pacemakers, e.g., for the carotid sinus
    • insulin pumps and nerve stimulators
    • non-MR safe lead wires
    • prosthetic heart valves (if dehiscence is suspected)
    • non-ferromagnetic stapedial implants
    • pregnancy
    • claustrophobia that does not readily respond to oral medication.
  4. Allergy to relevant imaging contrast agents, includes allergies to iodine or gadolinium-based contrast agents (if one class of agents is contra-indicated, then imaging with the other can still proceed).

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Other: Arm 1
The tests and procedures done as part of your standard-of-care biopsy preparation, participants will also have advanced MRI and CT scans performed no later than 2 weeks before the biopsy. Typically, these scans are done within 1 or 2 days before surgery to provide the most accurate images to the surgeon.
Performed by MRI Scan
Performed by CT Scan
Standard of Care Biopsy

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Safety and adverse events (AEs)
Time Frame: Through study completion; an average of 1 year
Incidence of Adverse Events, Graded According to National Cancer Institute Common Terminology Criteria for Adverse Events (NCI CTCAE)
Through study completion; an average of 1 year

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Dawid Schellingerhout, MD, M.D. Anderson Cancer Center

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

June 30, 2024

Primary Completion (Estimated)

October 31, 2025

Study Completion (Estimated)

October 31, 2025

Study Registration Dates

First Submitted

December 29, 2023

First Submitted That Met QC Criteria

December 29, 2023

First Posted (Actual)

January 10, 2024

Study Record Updates

Last Update Posted (Actual)

January 10, 2024

Last Update Submitted That Met QC Criteria

December 29, 2023

Last Verified

December 1, 2023

More Information

Terms related to this study

Additional Relevant MeSH Terms

Other Study ID Numbers

  • 2023-0671
  • NCI-2023-11127 (Other Identifier: NCI-CTRP Clinical Registry)

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Brain Malignancies

Clinical Trials on MRI Scan

3
Subscribe