声門上気道デバイスの構造変更
声門上気道デバイスの構造変更により、声門上換気モードと気管内換気モード間の交換が強化されます
The proposed A/Z modification of a supraglottic airway (SGA) incorporates an opening in the SGA body that enables access to the endotracheal tube (ETT) through the body of the SGA without the need of using an exchange catheter, thus enabling an ETT to move in the body of the SGA and convert a supraglottic to endotracheal ventilation. In its original form an adaptor made from same material currently used in the endotracheal tubes can make ventilation through the proposed airway device possible in exactly the same manner of a conventional SGA currently used. This adapter also known as the R-piece can be replaced with an ETT. The modification also allows placement of SGA over an existing ETT to convert and endotracheal (ET) to supraglottic (SG) mode of ventilation without the need to use an exchange catheter.
調査の概要
詳細な説明
The special design allows conversion of a telescopic coaxial portion (R piece), replacing with an ETT which can act coaxially to provide both supraglottic (up position) and endotracheal (down position) of ETT. See this modification in https://www.youtube.com/watch?v=iy84lALU1aI
Currently the proposed change to the conventional SGA has been made and feasibility tested on Manikins. The A/Z airway modification is also demonstrated in the attached link video https://www.youtube.com/watch?v=ukLOAC55iG8
In this study, we are trialing the A/Z concept on an original A/Z modification by a manufacturer on their currently used SGA. Thus instead of investigators making the changes by cutting a channel in a conventional SGA immediately before use in the Operating Room, they have asked a manufacturer to do so professionally.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Ohio
-
Cleveland、Ohio、アメリカ、44195
- Cleveland Clinic Foundation
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Adult patients
- scheduled for a general anesthesia procedure with ETT & muscle relaxation
Exclusion Criteria:
- Patients who are not able to consent
- Non English Speaking
- History of difficult airway
- Physical exam of airway which suggests difficulty in airway management or need to use special equipment
- BMI >35
- Gastroesophageal reflux disease
- Anesthetic plan other than general anesthesia
- Emergency procedures
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:デバイスの実現可能性
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:A/Z Airway
Patients under general anesthesia for surgical procedures who need airway management for ventilation. |
Patient receive supraglottic airway for general anesthesia which can be converted to endotracheal ventilation reversibly |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Test effect of A/Z modification of supraglottic airway device on rate of successful oxygenation and ventilation before beginning a full clinical trial
時間枠:During and immediately after the intervention
|
An alteration and structural modification in the supraglottic airway device can improve safety of airway exchange in patient needing general anesthesia, this proof of concept should show if the modification has any affect on oxygenation and ventilation. |
During and immediately after the intervention
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Rate of successful exchange from supraglottic to endotracheal ventilation using A/Z modified SGA
時間枠:During and immediately after intervention
|
Evaluate if a modification of configuration on "Laryngeal Mask Airway" improves safety during Supraglottic to Endotracheal conversion without using an exchange catheter |
During and immediately after intervention
|
|
Rate of successful exchange from endotracheal to supraglottic ventilation using A/Z modified SGA
時間枠:During and immediately after intervention
|
Evaluate if this modification can enhance smooth extubation after endotracheal intubation by converting an endotracheal tube to a supraglottic airway |
During and immediately after intervention
|
協力者と研究者
スポンサー
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- 20-163
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
試験データ・資料
-
ジャーナル要約
情報コメント:
A. Varvinskiy, T. Hinde, 21st Annual Scientific Meeting of the Difficult Airway Society: lessons learned and glimpses of the future , BJA: British Journal of Anaesthesia, Volume 119, Issue 3, September 2017, Pages e31-e47,
-
ジャーナルabstacts
情報コメント:
J. Law, I. Morris, Historical cohort study of 10 288 tracheal intubations facilitated by video laryngoscopy, British Journal of Anaesthesia, Volume 121, Issue 1, 2018, Pages e1-e2, ISSN 0007-0912, https://doi.org/10.1016/j.bja.2018.02.037. (https://www.sciencedirect.com/science/article/pii/S0007091218301831)
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。