이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

The Prostate Immobilization Device Study

2017년 6월 13일 업데이트: James Taylor
The purpose of this study is to compare reproducibility of the device position and location of the prostate rectum interface between two immobilization devices for radiation therapy of prostate carcinoma.

연구 개요

상세 설명

The investigator assessed the device position and location of the interface between rectum and prostate weekly during the course of treatment. This information was obtained using a conebeam CT scan on the treatment couch prior to a regularly scheduled radiation treatment. The conebeam CT scan is a standard tool for monitoring patient position and radiation treatment accuracy. Prior to each radiation treatment, the patient was placed in a vaclock immobilization device, then aligned with room lasers to skin tattoos. On board portal imaging was then employed using the KvKv match technique to place isocenter as simulated. For intact prostate treatment, alignment was made to implanted gold fiducial markers. For post prostatectomy patients, the alignment was to pelvic bony anatomy. After patient alignment was complete, a conebeam CT scan was obtained. The position of the anterior rectal wall and the interface between prostate and rectum was compared to the position of these structures at the time of simulation. Measurement was taken in the midline of the prostate gland between its base and apex of the maximum deviation of the rectum prostate interface from its position at the time of simulation. For post prostatectomy patients, a measurement was taken of the maximum deviation from simulation of interface between the rectum and the prostate bed/bladder. These measurements were recorded weekly by the treating radiation oncologist on the Physician Data Sheet.

The difficulty of device insertion, positioning and inflation was recorded daily by the treating personnel based on a scale in the PIDS Daily Radiation Therapist Questionnaire, from 1(none) to 5(unable to insert). These results were summarized by the clinical study coordinators on the PIDS Radiation Therapist Summary.

Patient expression of discomfort during device placement was recorded daily by treating personnel based on a scale in the PIDS Daily Radiation Therapist Questionnaire, from 1(none) to 5(intolerable). These responses will be summarized by the clinical study coordinators on the PIDS Radiation Therapist Summary.

연구 유형

중재적

등록 (실제)

60

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Wisconsin
      • Racine, Wisconsin, 미국, 53405
        • Wheaton Francsican Cancer Care - All Saints

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 이상 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

남성

설명

Inclusion Criteria:

  • 18 years of age or older
  • Clinically localized T1-3 N0-1 M0 adenocarcinoma of the prostate
  • Planned definitive radiation therapy

Exclusion Criteria:

  • Prior proctectomy
  • Rectal surgery within one year
  • Proctitis
  • Rectal carcinoma
  • Anal Stenosis
  • History of inflammatory bowel disease
  • Scleroderma
  • Systemic sclerosis
  • Refusal of treatment with immobilization device

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
활성 비교기: Miller enema air tip
The Miller enema air tip rectal balloon is inserted into the rectum prior to radiation simulation and also prior to each radiation treatment to immobilize prostate gland and displace rectal tissue during radiation therapy.
Miller Enema Air Tip is inserted into rectum prior to simulation and each radiation treatment.
다른 이름들:
  • Miller Enema Air Tip
활성 비교기: Radiadyne Immobilizer
The Radiadyne Immobilizer Treatment Device is inserted into the rectum prior to radiation simulation and also prior to each radiation treatment to immobilize prostate gland and displace rectal tissue during radiation therapy
Radiadyne Immobilizer is inserted into rectum prior to simulation and each radiation treatment

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Deviation of the Prostate Rectal Interface From Its Position at Time of Simulation.
기간: Up to 9 weeks
Measurements will be taken for at least 5, and up to 9, occasions on a weekly basis during each patient's course of treatment. An average value will be determined for each patient. An average of individual patient values will be determined for each immobilization device.
Up to 9 weeks

2차 결과 측정

결과 측정
측정값 설명
기간
Difficulty of Insertion.
기간: Up to nine weeks
Difficulty of device insertion was scored for each treatment by the treating radiation therapist on a scale from 1(easiest) to 5(most difficult). An average score was obtained at completion of therapy for each patient. At completion of the study, an average value was obtained for each immobilization device by averaging the average score for each patient .
Up to nine weeks
Patient Expression of Discomfort
기간: Up to nine weeks
Patient expression of discomfort was scored for each insertion by the treating radiation therapist on a scale from 1(none) to 5(intolerable). An average score was obtained at completion of therapy for each patient. At completion of the study, an average value was obtained for each immobilization device by averaging the average score for each patient .
Up to nine weeks

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

수사관

  • 수석 연구원: James H Taylor, MD, Wheaton Franciscan Cancer Care - All Saints

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작

2011년 8월 1일

기본 완료 (실제)

2014년 10월 1일

연구 완료 (실제)

2014년 10월 1일

연구 등록 날짜

최초 제출

2011년 7월 25일

QC 기준을 충족하는 최초 제출

2011년 8월 1일

처음 게시됨 (추정)

2011년 8월 3일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2017년 6월 29일

QC 기준을 충족하는 마지막 업데이트 제출

2017년 6월 13일

마지막으로 확인됨

2017년 6월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • 11-019-ASH

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

전립선 선암종에 대한 임상 시험

Miller Air tip에 대한 임상 시험

3
구독하다