The Effectiveness of BreatheMAX Breathing Device on Secretion Clearance (ESMOSC)
The Effectiveness of BreatheMAX Breathing Device on Airway Secretion Clearance in Patients With Ventilatory Dependence
Studie Overzicht
Toestand
Toestand
Conditie
Conditie
Interventie / Behandeling
Interventie / Behandeling
Studietype
Studietype
Inschrijving (Verwacht)
Inschrijving
Fase
Fase
- Fase 2
- Fase 3
Contacten en locaties
Studiecontact
Studiecontact
- Naam: Miss Sujittra Kluayhomthong, Bachelor
- Telefoonnummer: 081-379-0647
- E-mail: rabbit_tigger@hotmail.com
Studie Contact Back-up
- Naam: Mrs. Chulee Jones, Philosophy
- Telefoonnummer: 664-320-2399
- E-mail: Chujones46@yahoo.co.uk
Studie Locaties
-
-
Khon Kaen
-
Muang, Khon Kaen, Thailand, 40002
- Werving
- Pulmonary research room of physical therapy department, Faculty of associated medical sciences, Khon Kaen University
-
Contact:
- Sujittra Kluayhomthong, Bachelor
- Telefoonnummer: 668-139-0647
- E-mail: rabbit_tigger@hotmail.com
-
Contact:
- Chulee CU Jones, Philosophy
- Telefoonnummer: 664-320-2399
- E-mail: chujones46@yahoo.co.uk
-
-
Deelname Criteria
Geschiktheidscriteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- One sign of secretion accumulation in bronchi
- Stable cardiopulmonary function
- Good consciousness and good co-operation
Exclusion Criteria:
- Massive hemoptysis
- Pneumothorax (untreated)
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Crossover-opdracht
- Masker: Dubbele
Aantal wapens
Wapens en interventies
Deelnemersgroep / ArmDeelnemersgroep / Arm |
Interventie / BehandelingInterventie / Behandeling |
|---|---|
|
Experimenteel: breathing exercise
BreatheMAX breathing device is Water pressure Threshold Bottle.
The level of water in the cylinder determines the load for treatment.
In the treatment using 20% PNIP (Peak negative inspiratory pressure) was performed with 6-10 breaths/set; 10 set/day
|
secretion clearance, breathing exercise
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
secretion wet weight (gram)
Tijdsspanne: Three hours before, ten hours after treatment and night-time (02.00-07.00 am.)
|
Airway mucus secretion was collected for three hours before and ten hours after treatment based on an auditory airway secretion sound and collected again at 02.00-07.00
am.The mucus secretion was collected by sterile suctioning technique via tracheostomy tube without adding any saline or sterile water.
|
Three hours before, ten hours after treatment and night-time (02.00-07.00 am.)
|
|
viscosity of secretion
Tijdsspanne: Three hours before and after treatment
|
The secretion were collected in three hours before and after treatment, It were measured viscosity by First The mucus was gently homogenized by tissue grinder 5 ml (Cw11-205, Cowie, UK) for six minute at 37 degree celsius Second using Micro-Oswald viscometers with a capillary diameter of 0.77 mm for viscosity measure at same temperature in each sample(before and after).
|
Three hours before and after treatment
|
Secundaire uitkomstmaten
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Heart rate (beat/min)
Tijdsspanne: Before, during breathing exercise with device and immediate after treatment
|
Heart rate was monitored before, during and immediate after breathing exercise with BreatheMAX (6-10 beats/set, 10 set/day and rest between ste for 1 minute)
|
Before, during breathing exercise with device and immediate after treatment
|
|
Oxygen saturation (%SpO2)
Tijdsspanne: Before, during breathing exercise with device and immediate after treatment
|
Oxygen saturation was monitored before, during and immediate after breathing exercise with BreatheMAX (6-10 beats/set, 10 set/day and rest between set for 1 minute)
|
Before, during breathing exercise with device and immediate after treatment
|
|
Respiratory rate (times/min)
Tijdsspanne: In rest interval between set (1 minute)
|
Respiratory rate was measured by manual for 1 minute before, rest interval between set and immediate after breathing exercise with device (during the patients reconnection mechanical ventilation)
|
In rest interval between set (1 minute)
|
Medewerkers en onderzoekers
Sponsor
Sponsor
Onderzoekers
Onderzoekers
- Studie stoel: Sujittra Kluayhomthong, Bachelor, Physical Therapy department, Faculty of Associated Medical Sciences, Khon Kaen university
- Studie directeur: Chulee CU Jones, Philosophy, Physical Therapy Department, Faculty of Associated Medical Sciences, Khon Kaen university, Thailand
- Studie directeur: Wilaiwan Khrisanapant, Philosophy, Department of physiology, Faculty of medicine, Khon Kaen university
Studie record data
Bestudeer belangrijke data
Studie start
Studie start
Primaire voltooiing (Werkelijk)
Primaire voltooiing
Studieregistratiedata
Eerst ingediend
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Eerst geplaatst
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update geplaatst
Laatste update ingediend die voldeed aan QC-criteria
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
Andere studie-ID-nummers
- 47660279
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .
Klinische onderzoeken op Longziekte
-
NCT07267247VoltooidCardiotoxiciteit | Niet-kleincellig longcarcinoom (MeSH Term: Carcinoma, Non-Small-Cell Lung) | Geneesmiddelgerelateerde bijwerkingen en ongewenste reacties (MeSH-term) | Egfr Tyrosinekinaseremmer
-
NCT07469709WervingBorstkanker | Eierstokkanker | Colo-rectale kanker | Melanoom (huidkanker) | Niet-kleincellig longcarcinoom (MeSH Term: Carcinoma, Non-Small-Cell Lung)
Klinische onderzoeken op BreatheMAX breathing device
-
NCT02553200VoltooidRetentie van bronchiale secretie
-
NCT02398071OnbekendChronische obstructieve longziekte
-
NCT02847416Voltooid
-
NCT07328477VoltooidPijn | Misselijkheid | Ongerustheid | Endoscopische retrograde cholangiopancreaticografie
-
NCT03068026VoltooidChronische obstructieve longziekte
-
NCT07506317Voltooid
-
NCT05533931Nog niet aan het werven
-
NCT00792441Onbekend
-
NCT06988800VoltooidOngerustheid | Depressie niet anders gespecificeerd | Zelfwerkzaamheid