Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Segurança e Desempenho Clínico do Sistema de Scaffold Reabsorvível de Magnésio (RMS) Freesolve em Indivíduos com Lesões da Artéria Coronária (BIOMAG-III)

10 de novembro de 2026 atualizado por: Teleflex

Segurança e Desempenho Clínico do Sistema de Scaffold Coronário de Magnésio Reabsorvível com Libertação de Fármaco (Freesolve) no Tratamento de Indivíduos com Lesões de Novo em Artérias Coronárias Nativas

The objective of this study is to assess the safety and efficacy of the Freesolve resorbable magnesium scaffold (RMS) in the treatment of subjects with up to two de novo lesions in native coronary arteries compared to the Xience coronary drug-eluting stent (DES) system

Visão geral do estudo

Descrição detalhada

The BIOMAG-III clinical trial is a prospective, international, multi-center, single-blinded, randomized controlled, non-inferiority trial to compare the Freesolve Sirolimus Eluting Coronary Resorbable Magnesium Scaffold (Freesolve RMS) System with the Xience Everolimus Eluting Stent (Xience DES) System. with respect to Target Lesion Failure (TLF) rate at 12 months. Subjects will be randomized in a 2:1 fashion Freesolve to Xience. A total of up to 1859 subjects will be randomized at up to 120 total sites worldwide including North America, Europe, and Asia Pacific. Clinical follow-up will be conducted at 1, 6, and 12 months and at 2, 3, 4, and 5 years post-procedure.

Tipo de estudo

Intervencional

Inscrição (Estimado)

1859

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Locais de estudo

    • District of Columbia
      • Washington D.C., District of Columbia, Estados Unidos, 20010
        • Recrutamento
        • MedStar Washington Hospital Center
    • Texas
      • Dallas, Texas, Estados Unidos, 75226
        • Recrutamento
        • Baylor Scott & White The Heart Hospital - Dallas
      • Plano, Texas, Estados Unidos, 75093
        • Recrutamento
        • The Heart Hospital Baylor Plano
    • West Virginia
      • Charleston, West Virginia, Estados Unidos, 25304
        • Recrutamento
        • Charleston Area Medical Center
    • Gard
      • Nîmes, Gard, França, 30900
        • Recrutamento
        • CHU de Nîmes
      • Riga, Letônia, LV-1002
        • Recrutamento
        • Pauls Stradins Clinical University Hospital
    • Lower Silesian Voivodeship
      • Lubin, Lower Silesian Voivodeship, Polônia, 59-301
        • Recrutamento
        • Miedziowe Centrum Zdrowia S.A.

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos a 80 anos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Clinical Inclusion Criteria:

  1. Subject is ≥ 18 years and ≤ 80 years of age

  2. Subject has provided written informed consent as approved by the Ethics Committee / Institutional Review Board (IRB) of the respective clinical site prior to the study related procedures

  3. Subject is eligible for PCI according to the applicable guidelines

  4. Subject is an acceptable candidate for coronary artery bypass surgery

  5. Subjects with stable or unstable angina pectoris, documented silent ischemia/abnormal physiologic testing or hemodynamically stable non-ST elevation myocardial infarction (NSTEMI) patients without angiographic evidence of thrombus at target lesion

    Note: STEMI patients may be eligible for the study for treatment of selected non-culprit lesions, if:

    • Subject and target lesion(s) meet all inclusion and no exclusion criteria and consent occurs at least ≥ 72 hours after successful treatment of the culprit lesion(s) [lesion(s) causing the acute STEMI];
    • Subject is hemodynamically stable with documented declining cardiac biomarkers;
    • Target lesion(s) to be treated are not located in the culprit vessel(s) and are not culprit lesion(s)
  6. Subject is eligible for Dual Antiplatelet Therapy (DAPT) with aspirin plus either clopidogrel, prasugrel, ticagrelor or ticlopidine

  7. Documented left ventricular ejection fraction (LVEF) ≥ 30% within 6 months prior to or during the procedure (prior to randomization)

  8. Subject is willing and able to comply with protocol requirements, including completion of study visits for the duration of the study

Angiographic Inclusion Criteria:

  1. Subjects with a maximum of two single de novo target lesions each in separate native coronary arteries
  2. Target vessel must have a reference diameter between 2.5-4.2 mm by operator visual estimation, which may be assisted by Quantitative Coronary Angiography (QCA) / Intravascular Ultrasound (IVUS) / Optical Coherence Tomography (OCT)
  3. Target lesion(s) must be ≤ 36 mm in length by operator visual estimation, which may be assisted by QCA / IVUS / OCT, (or < 20 mm for target lesion(s) to be treated with a study device < 3.0 mm in diameter) and must be amenable to treatment with a single study device
  4. Target lesion stenosis ≥ 50% and < 100% by operator visual estimation, which may be assisted by QCA / IVUS / OCT. Target lesion stenosis < 70% by visual estimation, should have clinical justification for treatment as per local standards.
  5. Target lesion must have a Thrombolysis in Myocardial Infarction (TIMI) flow ≥ 1

Clinical Exclusion Criteria:

  1. Subject is pregnant and/or breastfeeding or intends to become pregnant during the duration of the study
  2. Subject has clinical symptoms and/or electrocardiogram (ECG) changes consistent with STEMI < 72 hours prior to the index procedure Note: Hemodynamically stable non-STEMI (NSTEMI) subjects are eligible for study enrollment
  3. Subject has undergone prior PCI within the target vessel during the last 12 months prior to the index procedure or prior PCI within a non-target vessel < 72 hours prior to the index procedure
  4. Subject is on dialysis or has impaired renal function (serum creatinine > 2.5 mg/dL or 221 µmol/L, determined within 7 days prior to the index procedure)
  5. Subject has a known allergy to contrast medium that cannot be adequately premedicated, or any known allergy to aspirin, P2Y12 inhibitors, both heparin and bivalirudin, sirolimus, everolimus (or similar limus drugs), poly L-lactide, the scaffold material (magnesium, aluminum, tantalum), or Xience stent material (cobalt, chromium, tungsten, nickel, methacrylic polymer, and fluoropolymer)
  6. Subject is receiving oral or intravenous immunosuppressive therapy (inhaled steroids are permitted) or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus; diabetes mellitus is permitted)
  7. Life expectancy less than 1 year
  8. Planned surgery or dental surgical procedure within 6 months after index procedure, unless DAPT can be maintained
  9. In the investigator's opinion subject will not be able to comply with the follow-up requirements
  10. Subjects under oral anticoagulation therapy (OAC) prior to index procedure unless DAPT + OAC (i.e., triple therapy) can be maintained for a minimum of 1 month
  11. Subject has had a stroke or transient ischemic attack (TIA) within 6 months prior to the index procedure
  12. Subject with active bleeding disorder, active coagulopathy, or any other reason, who is ineligible for DAPT
  13. Subject is currently participating or plans to participate in another study with an investigational device or an investigational drug
  14. Subject has known severe aortic or mitral valve stenosis/insufficiency or has previously undergone transcatheter aortic valve replacement (TAVR)

Angiographic Exclusion Criteria:

  1. Target vessel has been previously treated and the target lesion is within 5 mm proximal or distal to the previously treated lesion
  2. Left main coronary artery disease
  3. Target lesion is totally occluded (100% stenosis)
  4. Thrombus in target vessel
  5. Future planned staged PCI either in target or non-target vessel
  6. Ostial target lesion within the left anterior descending (LAD), left circumflex (LCX), or right coronary artery (RCA) (within 5.0 mm of vessel origin)
  7. Target lesion involves a side branch ≥ 2.0 mm in diameter that requires a two-device strategy after pre-dilatation
  8. Target lesion is located in or supplied by an arterial or venous bypass graft
  9. Target lesion with excessive tortuosity proximal to or within the lesion based on visual estimation or heavily calcified target lesion which cannot be adequately pre-dilated by a non-compliant and/or cutting/scoring balloon as described in angiographic exclusion criteria 10
  10. Target lesion requires treatment with a device other than the non-compliant balloon and/or cutting/scoring balloon prior to scaffold/stent placement (including but not limited to atherectomy devices, intravascular lithotripsy, drug-coated balloons, etc.)
  11. Target vessel was treated with brachytherapy any time prior to the index procedure.
  12. Unsuccessful pre-dilatation, defined as residual stenosis > 20% (by visual estimation) and/or angiographic complications (e.g., distal embolization, side branch closure, flow-limiting dissections)

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Freesolve RMS

Intervention with a Freesolve Sirolimus Eluting Coronary Resorbable Magnesium Scaffold (RMS) System

Freesolve Sirolimus-Eluting Coronary Resorbable Magnesium Scaffold (RMS) System, a drug-eluting balloon-expandable resorbable scaffold

Comparador Ativo: Xience DES

Intervention with a Xience Everolimus Eluting Stent System

Xience Everolimus Eluting Stent System

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Target Lesion Failure (TLF) rate at 12 months post-index procedure
Prazo: 12 months

The primary endpoint is Target Lesion Failure (TLF) at 12 months, a composite of Cardiac Death, Target Vessel Q-wave or non-Q wave MI, or clinically driven target lesion revascularization (TLR).

12 months

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Morte cardíaca
Prazo: 1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento de referência
1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento de referência
Morte cardiovascular
Prazo: 1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento de referência
1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento de referência
Mortalidade por todas as causas
Prazo: 1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento índice
1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento índice
Enfarte do miocárdio do vaso-alvo, de acordo com as definições do endpoint primário para enfarte do miocárdio periprocedimental e não periprocedimental
Prazo: 1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento de referência
1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento de referência
Qualquer IAM (incluindo território de vaso não-alvo)
Prazo: 1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento índice
1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento índice
TLR clinicamente orientado
Prazo: 1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento de referência
1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento de referência
TVR clinicamente orientado
Prazo: 1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento de referência
1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento de referência
Trombose do suporte/stent (definitiva, definitiva/provável, provável) de acordo com os critérios do Academic Research Consortium (ARC-2) para trombose do suporte/stent aguda, subaguda, tardia, muito tardia e cumulativa
Prazo: 1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento índice
1, 6, 12 meses e 2, 3, 4 e 5 anos após o procedimento índice
Procedure success
Prazo: Hospital Discharge (6-24 hours post-index procedure)

Procedure success defined as achievement of < 30% final residual diameter stenosis [by Quantitative Coronary Angiography (QCA) or visual estimation] of the target lesion using the assigned study device only, without the occurrence of cardiac death, Q-wave or non-Q-wave MI, or repeat revascularization of the target lesion during the hospital stay

Hospital Discharge (6-24 hours post-index procedure)
Device Success
Prazo: Hospital Discharge (6-24 hours post-index procedure)

Device Success defined as a final residual diameter stenosis of < 30% by QCA or visual estimation, using the assigned device only with

  • successful delivery of the device to the target lesion, and
  • appropriate device deployment, and
  • successful removal of the delivery system
Hospital Discharge (6-24 hours post-index procedure)
Target lesion failure (TLF)
Prazo: Time Frame: 1, 6 months and 2, 3, 4 and 5 years post-index procedure

TLF is defined as a composite of Cardiac Death, Target Vessel Q-wave or non-Q-wave myocardial infarction (MI), or clinically driven Target Lesion Revascularization (TLR)

Time Frame: 1, 6 months and 2, 3, 4 and 5 years post-index procedure
Target Vessel Failure (TVF)
Prazo: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure

Target Vessel Failure (TVF), a composite of Cardiac Death, Target Vessel Q-wave or non-Q wave MI, or clinically driven Target Vessel Revascularization (TVR)

1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Powered Secondary Endpoint 1: TLF from 1-5 Years
Prazo: 1 to 5 years post-index procedure

A powered secondary endpoint of cumulative TLF rates between 1 and 5 years post-procedure will be evaluated.

1 to 5 years post-index procedure
Powered Secondary Endpoint 2: TLF at 12 Months in the Diabetic Population
Prazo: 12 months post-index procedure

A powered secondary endpoint of TLF at 12 months in the diabetic population will be evaluated.

12 months post-index procedure

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

11 de junho de 2026

Conclusão Primária (Estimado)

1 de junho de 2029

Conclusão do estudo (Estimado)

1 de junho de 2033

Datas de inscrição no estudo

Enviado pela primeira vez

20 de novembro de 2025

Enviado pela primeira vez que atendeu aos critérios de CQ

20 de novembro de 2025

Primeira postagem (Real)

2 de dezembro de 2025

Atualizações de registro de estudo

Última Atualização Postada (Real)

12 de novembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

10 de novembro de 2026

Última verificação

1 de novembro de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Descrição do plano IPD

No IPD sharing is planned at this time. This study evaluates an investigational device under an FDA IDE. The sponsor may consider sharing de-identified IPD under controlled access following completion of primary endpoint analysis and regulatory review. Summary results will be reported in scientific publications and public registries.

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Sim

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever