The Effectiveness of SensAwake™ for Continue Positive Airway Pressure Treatment of Obstructive Sleep Apnea Patients
Effects of Pressure Control Device (SensAwake™) on Obstructive Sleep Apnea (OSA) Patients Who Remove the Mask for Unknown Reasons During Automatic Continuous Positive Airway Pressure (Auto-CPAP) Therapy
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
1. Participants will be recruited from OSA patients who will remove CPAP himself without any notable reasons.
Exclusion Criteria:
- Unstable cardiovascular disease (untreated or resistant hypertension acceptable).
- Inability to tolerate CPAP due to nasal obstruction or claustrophobia as determined by the study investigator.
- Any known factor or disease that might interfere with treatment compliance, study conduct or interpretation of the results such as psychiatric disease, history of non compliance to medical regimens, or unwillingness to comply with study requirements.
- Any known factor that result in mask taken of such as skin discomfort, nasal obstruction, water dripping inside the tubing system etc.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: CROSSOVER
- Masking: DOUBLE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
NO_INTERVENTION: APAP begins without SensAwake
Patients will receive CPAP treatment without SensAwake™ activation for two weeks, then crossed-over to CPAP treatment with SensAwake™ activation for additional two weeks.
|
|
|
EXPERIMENTAL: APAP begins with SensAwake
Patients will receive CPAP treatment with SensAwake™ activation for two weeks, then crossed-over to CPAP treatment without SensAwake™ activation for additional two weeks. SensAwake™ modification: SensAwake™ is a new design based on the research of Doctor Ayappa 5 years ago. The SensAwake™ modification to the Fisher and Paykel automatically titrating positive airway pressure (APAP) device aims to sense whether the patient is awake via respiratory patterns that differentiate between sleep and wake. Upon sensing that the patient is awake the device is able to reduce positive airway pressure PAP aiming to improve patient comfort which should result in more consolidated sleep. |
SensAwake™ is a new design based on the research of Doctor Ayappa 5 years ago.
The SensAwake™ modification to the Fisher and Paykel automatically titrating positive airway pressure (APAP) device aims to sense whether the patient is awake via respiratory patterns that differentiate between sleep and wake.
Upon sensing that the patient is awake the device is able to reduce positive airway pressure PAP aiming to improve patient comfort which should result in more consolidated sleep.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Compliance of Auto-CPAP Therapy
Time Frame: 2 weeks
|
Objective data recorded in the auto-CPAP machine, Percentage of nights of using auto-CPAP for at least 4 hours during therapy.
|
2 weeks
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Average SA Detections
Time Frame: 2 weeks
|
Average detects of arousal per hours.
(Objective data recorded in the auto-CPAP machine)
|
2 weeks
|
|
Average Pressures of Auto-CPAP Machine
Time Frame: 2 weeks
|
Average Pressures of Auto-CPAP Machine (Objective data recorded in the auto-CPAP machine)
|
2 weeks
|
|
90th Percentile Pressures of Auto-CPAP Machine
Time Frame: 2 weeks
|
90th percentile pressures of auto-CPAP machine (Objective data recorded in the auto-CPAP machine)
|
2 weeks
|
|
Average Leaks of Auto-CPAP Machine
Time Frame: 2 weeks
|
Average leaks of auto-CPAP machine (Objective data recorded in the auto-CPAP machine)
|
2 weeks
|
|
90th Percentile Leaks of Auto-CPAP Machine
Time Frame: 2 weeks
|
Average leaks of auto-CPAP machine (Objective data recorded in the auto-CPAP machine)
|
2 weeks
|
|
Residual Apnea-Hypopnea Index (AHI)
Time Frame: 2 weeks
|
Residual Apnea-Hypopnea index (Objective data recorded in the auto-CPAP machine) means events of apnea and hypopnea per hour during CPAP therapy.
|
2 weeks
|
|
Time Used of Auto-CPAP Machine
Time Frame: 2 weeks
|
Average Time used of auto-CPAP machine (Objective data recorded in the auto-CPAP machine)
|
2 weeks
|
|
Percentage of Day Used of Auto-CPAP Machine
Time Frame: 2 weeks
|
Percentage of day used of auto-CPAP machine (Objective data recorded in the auto-CPAP machine)
|
2 weeks
|
|
Pittsburgh Sleep Quality Index (PSQI)
Time Frame: 2 weeks
|
The Pittsburgh Sleep Quality Index (PSQI) is a self-report questionnaire that assesses sleep quality over a 1-month time interval.
Overall score is ranging from 0 to 21, where lower scores denote a healthier sleep quality.
|
2 weeks
|
|
Epworth Sleepiness Score (ESS)
Time Frame: 2 weeks
|
The ESS is a self-administered questionnaire with 8 questions.
The ESS score can range from 0 to 24, where higher scores denote a worse daytime sleepiness.
|
2 weeks
|
|
Nasal Obstruction Symptom Evaluation (NOSE)
Time Frame: 2 weeks
|
The Nasal Obstruction Symptom Evaluation (NOSE) is a self-administered questionnaire with 11 questions.
The NOSE score can range from 0 to 44, where higher scores denote a worse nasal obstruction.
|
2 weeks
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Li-Pang Chuang, MD, ChangGungMemorialHospital
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 103-7083B
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Obstructive Sleep Apnea
-
NCT07399782Not yet recruitingSleep Apnea/Hypopnea Syndrome | Sleep Apnea Syndrome, Obstructive | Sleep Apnea Syndrome (OSAS) | Sleep Apnea - Obstructive
-
NCT07186725RecruitingObstructive Sleep Apnea (SAOS) | Obstructive Sleep Apnea (OSAS)
-
NCT07301762Enrolling by invitationObstructive Sleep Apnea | OSA | Obstructive Sleep Apnea (OSA)
-
NCT07465874Not yet recruitingObstructive Sleep Apnea | Sleep Apnea
-
NCT07332442RecruitingObstructive Sleep Apnea | Sleep Apnea
-
NCT07545421Not yet recruitingObstructive Sleep Apnea
-
NCT07337239Not yet recruiting
-
NCT07331285Not yet recruitingObstructive Sleep Apnea
-
NCT07303452RecruitingObstructive Sleep Apnea
Clinical Trials on SensAwake™ modification
-
NCT01517763Terminated
-
NCT01831258CompletedObstructive Sleep Apnea
-
NCT02549508CompletedObstructive Sleep Apnea (OSA) | Post-Traumatic Stress Disorder (PTSD)
-
NCT02971436Terminated
-
NCT02721329CompletedInsomnia | Obstructive Sleep Apnea
-
NCT04137367CompletedMajor Depressive Disorder