Assessment of Portable Oxygen Concentrators in Infants Undergoing Hypoxic Challenge Testing.
Assessment of Portable Oxygen Concentrators in Infants Undergoing Hypoxic Challenge Testing. A Randomized Crossover Study.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Mallorca
-
Palma Mallorca, Mallorca, Spain
- Hospital Son Espases
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
Patients with baseline Sat.O2 >94% AND
- <1 year with neonatal respiratory disease
- required oxygen supply in the last 6 months
- chronic respiratory disease (eg cystic fibrosis, obstructive or restrictive pulmonary disease) with FEV 1 (forced expiratory volume in 1 second) or FVC (forced vital capacity) <50%.
Exclusion Criteria:
- acute respiratory infection
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: CROSSOVER
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXPERIMENTAL: cPOC - pPOC
Randomized crossover study (according to a random number table): Patients are allocated randomly to two study groups (cPOC/pPOC).
In case of Sat.O2 drop ≤ 85% during HCT, oxygen is administered by cPOC (continuous-flow).
For patients who show a positive POC hypoxic reversal, HCT is repeated at 24 hours and oxygen is administered by pPOC (pulsed-flow).
|
SeQal Eclipse 3® on continuous-flow (SeQual,Ball Ground,GA): flow rate 2 litre per minute (lpm).
InogenOne G3® (Inogen,Goleta,CA) on pulsed-flow mode: setting 2 (flow rate 420 ml/min, 16.8 ml +/- 3ml per bolus at 25 rpm).
|
|
EXPERIMENTAL: pPOC - cPOC
Randomized crossover study (according to a random number table): Patients are allocated randomly to two study groups (cPOC/pPOC).
In case of Sat.O2 drop ≤ 85% during HCT, oxygen is administered by pPOC (pulsed-flow).
For patients who show a positive POC hypoxic reversal, HCT is repeated at 24 hours and oxygen is administered by cPOC (continuous-flow).
|
SeQal Eclipse 3® on continuous-flow (SeQual,Ball Ground,GA): flow rate 2 litre per minute (lpm).
InogenOne G3® (Inogen,Goleta,CA) on pulsed-flow mode: setting 2 (flow rate 420 ml/min, 16.8 ml +/- 3ml per bolus at 25 rpm).
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Assessment of portable oxygen concentrators (POCs) to change HCT induced hypoxia (Sat.O2 drop ≤ 85%).
Time Frame: 20 minutes
|
Hypoxia (Sat.O2 drop ≤ 85%) measured by Masimo SET Radical-7 Electron® pulse oximeter is induced performing HCT.
Thereafter oxygen is administered through cPOC or pPOC until baseline Sat.O2 (Sat.O2 >93%) is achieved.
|
20 minutes
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
POC comparison to change HCT induced hypoxia (Sat.O2 drop ≤ 85%).
Time Frame: 20 minutes
|
Compare the capacity of different POCs: continuous flow (cPOC) versus pulsed flow (pPOC) to change HCT induced hypoxia (Sat.O2 ≤ 85%) until baseline Sat.O2 (Sat.O2 >93%) is achieved.
|
20 minutes
|
|
Relate patient age (months) to POCs capacity to change HCT induced hypoxia (Sat.O2 drop ≤ 85%).
Time Frame: 20 minutes
|
Relationship between patient age (months) and POCs capacity to change hypoxic state (≤ 85%) to baseline Sat.O2 (>93%) measured by Masimo SET Radical-7 Electron®
|
20 minutes
|
|
Relate patient weight (kilograms) to POCs capacity to change HCT induced hypoxia (Sat.O2 drop ≤ 85%).
Time Frame: 20 minutes
|
Relationship between patient weight (kilograms) and POCs capacity to change hypoxic state (≤ 85%) to baseline Sat.O2 (>93%) measured by Masimo SET Radical-7 Electron®
|
20 minutes
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Sebastian Sailer, MD, Hospital Son Espases
Publications and helpful links
General Publications
- Ahmedzai S, Balfour-Lynn IM, Bewick T, Buchdahl R, Coker RK, Cummin AR, Gradwell DP, Howard L, Innes JA, Johnson AO, Lim E, Lim WS, McKinlay KP, Partridge MR, Popplestone M, Pozniak A, Robson A, Shovlin CL, Shrikrishna D, Simonds A, Tait P, Thomas M; British Thoracic Society Standards of Care Committee. Managing passengers with stable respiratory disease planning air travel: British Thoracic Society recommendations. Thorax. 2011 Sep;66 Suppl 1:i1-30. doi: 10.1136/thoraxjnl-2011-200295. No abstract available.
- Gong H Jr, Tashkin DP, Lee EY, Simmons MS. Hypoxia-altitude simulation test. Evaluation of patients with chronic airway obstruction. Am Rev Respir Dis. 1984 Dec;130(6):980-6. doi: 10.1164/arrd.1984.130.6.980.
- Blakeman TC, Rodriquez D Jr, Gerlach TW, Dorlac WC, Johannigman JA, Branson RD. Oxygen requirement to reverse altitude-induced hypoxemia with continuous flow and pulsed dose oxygen. Aerosp Med Hum Perform. 2015 Apr;86(4):351-6. doi: 10.3357/AMHP.4184.2015.
- Fischer R, Wanka ER, Einhaeupl F, Voll K, Schiffl H, Lang SM, Gruss M, Ferrari U. Comparison of portable oxygen concentrators in a simulated airplane environment. Respir Med. 2013 Jan;107(1):147-9. doi: 10.1016/j.rmed.2012.10.001. Epub 2012 Oct 22.
- Bunel V, Shoukri A, Choin F, Roblin S, Smith C, Similowski T, Morelot-Panzini C, Gonzalez J. Bench Evaluation of Four Portable Oxygen Concentrators Under Different Conditions Representing Altitudes of 2438, 4200, and 8000 m. High Alt Med Biol. 2016 Dec;17(4):370-374. doi: 10.1089/ham.2016.0056.
- Chen JZ, Katz IM, Pichelin M, Zhu K, Caillibotte G, Finlay WH, Martin AR. In Vitro-In Silico Comparison of Pulsed Oxygen Delivery From Portable Oxygen Concentrators Versus Continuous Flow Oxygen Delivery. Respir Care. 2019 Feb;64(2):117-129. doi: 10.4187/respcare.06359. Epub 2019 Jan 29.
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- cop2016
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Hypoxia, Altitude
-
NCT07585227Not yet recruitingHypoxia | Hypoxia, Brain | Hypoxia in Healthy Individuals | Hypoxia, Altitude | Altitude Hypoxia | Altitude | Hypoxia Altitude Simulation Test | Hypoxia Brain | Normobaric Hypoxia
-
NCT07063732RecruitingExercise | High Altitude Hypoxia
-
NCT04075565CompletedHypoxia | Altitude Sickness | Mountain Sickness | Hypoxia, Altitude | Altitude Hypoxia | Altitude
-
NCT03312361CompletedNeuromuscular Diseases | High Altitude Hypoxia
-
NCT07431567RecruitingHypoxia | Altitude Hypoxia | Right Heart Function | Normobaric Hypoxia
-
NCT07431554RecruitingHypoxia | Altitude Hypoxia | Right Ventricular Function | Normobaric Hypoxia
-
NCT07431580RecruitingHypoxia | Hypoxia, Altitude | Right Ventricular Function | Normobaric Hypoxia
-
NCT07193771RecruitingAltitude Hypoxia | High Altitude Effects | Respiratory Distress Syndrome, Pediatric
-
NCT04915378CompletedHigh Altitude | Hypoxia Altitude Simulation Test
-
NCT05867719Completed
Clinical Trials on continuous-flow portable oxygen concentrator (cPOC)
-
NCT00875719CompletedChronic Obstructive Pulmonary Disease
-
NCT07512687RecruitingChronic Obstructive Pulmonary Disease | Interstitial Lung Disease | Hypoxemia
-
NCT00592033Completed
-
NCT06000332CompletedNocturnal Hypoxemia
-
NCT05719363Completed
-
NCT01653730CompletedPulmonary Fibrosis | Chronic Obstructive Lung Disease
-
NCT06767904Not yet recruitingChronic Obstructive Pulmonary Disease | Interstitial Lung Disease