Evaluating NeuroVision's Neural Vision Correction (NVC) Myopia Treatment

August 28, 2018 updated by: Donald Mutti, Ohio State University

Evaluating the Efficacy of NeuroVisions's NVC Treatment for Low Myopia

The purpose of the present study is to carry out a trial to evaluate the clinical efficacy of the NeuroVision Low Myopia Treatment.

The specific questions to be answered are:

  1. Is there an improvement in vision following the treatment without bringing about a change in the subject's prescription for glasses?
  2. Can any treatment effect be seen at 6 months and 12 months after the termination of the treatment?

Study Overview

Status

Terminated

Conditions

Detailed Description

Myopia and its treatment modalities are one of the widely studied areas in vision research. So far all the treatment options have been optical i.e., patients with myopia are either corrected with spectacles, contact lenses or refractive surgery to provide clear vision. NeuroVision's NVC vision correction technology will be a novel method in the treatment of low myopia as the technology is directed at specific neuronal interactions at the level of the visual cortex (area responsible for vision in the brain). It uses a non-invasive, patient-specific treatment that purports to improve neuronal efficiency and induce improvement in the overall ability to see due to a reduction in noise and increase in signal strength. As visual perception quality depends both on the input received through the eye and the processing in the visual cortex, NeuroVision's technology is hypothesized to compensate for blurred (myopic) inputs, by enhancing neural processing.

We will conduct a clinical evaluation of the effectiveness of this system. The subject will be exposed to a set of visual stimulations (pattern with black and white lines) and visual threshold level will be obtained. The subject will look at these patterns on a computer. The treatment will be applied in successive 30-40 minute sessions, administered 2-3 times a week, for a total of 40 sessions. Every 5 sessions, subject's visual performance (visual acuity, ability to see letters of varying size, and CSF, ability to see black and white lines of varying contrast) will be tested in order to continuously monitor a subject's progress. At the end of a session, the data will be sent to the NeuroVision Web Server. Proprietary algorithmic software will analyze the patient's performance and progress and will generate the parameters for the next treatment session. The purpose of the study is to assess the effect on corrected or uncorrected visual performance following treatment.

Study Type

Interventional

Enrollment (Actual)

2

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Ohio
      • Columbus, Ohio, United States, 43210
        • College of Optometry, The Ohio State University

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 59 years (Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Age should be between 18 to 59 years
  • Spherical equivalent in the worst eye should not exceed -1.5 DS and the astigmatism should not exceed -0.75 DC.
  • The subject's refractive status is stable, with no increase beyond 0.5D in sphere or cylinder over the last six months. That is, the subject's spectacle prescription should not differ from the auto-refraction value by 0.50D.
  • Unaided visual acuity is 0.6 LogMAR or better in the eye with the poorer unaided acuity
  • Unaided visual acuity is 0.1 LogMAR or worse in the eye with better unaided acuity
  • Unaided visual acuity difference between both eyes is less than 0.3 LogMAR
  • Best-corrected visual acuity is 0.04 LogMAR or better in both eyes.
  • The subject should be aware that the study has the following features:

    1. The recommended pace for the treatment sessions is at least 3 sessions per week.
    2. Interruptions should not be longer than 2 weeks during the treatment course. Note: The subject is free to voluntarily withdraw from the study at any time.

Exclusion Criteria:

  • The subject suffers from any other visually disabling eye disease(s) or other causes for the reduced visual acuity, aside from myopia and/or astigmatism
  • The subject suffers from myopia-related visual complications resulting in visual loss, including myopic macular degeneration, myopic cataract and previous or pre-existing myopic retinal detachment.
  • The subject is suffering from Diabetes Mellitus.
  • The subject suffers from Migraines
  • The subject suffers from Epilepsy
  • The subject is pregnant. (It is not recommended to include pregnant women because of the expected visual fluctuations. The NV treatment , basically using a computer, has no impact on the pregnancy.) No pregnancy testing will be done but will be identified through verbal history. The study has use of tropicamide drug (dilation drops) and proparacaine (topical anesthetic), which are a routinely used eye drop in everyday clinical practice and no adverse effects have been reported so far on pregnant women or fetus.
  • The subject has an activity limitation due to medical disorders (including migraines, seizure disorders, etc.), medications, or emotional status that might potentially impair the subject's ability to perform the treatment.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: A
NeuroVision's NVC treatment for low myopia

NeuroVision's NVC vision correction technology is a method in the treatment of low myopia as the technology is directed at specific neuronal interactions at the level of the visual cortex (area responsible for vision in the brain).

The subject will be exposed to a set of visual stimulations (pattern with black and white lines) and visual threshold level will be obtained. The subject will look at these patterns on a computer. The treatment will be applied in successive 30-40 minute sessions, administered 2-3 times a week, for a total of 40 sessions. Every 5 sessions, subject's visual performance (visual acuity and CSF) will be tested in order to continuously monitor a subject's progress.

No Intervention: B
The subjects in this group will serve as controls and will be the no intervention group.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
Visual Acuity
Time Frame: Every 5th visit
Every 5th visit
Contrast Sensitivity Function
Time Frame: Every 5th visit
Every 5th visit

Secondary Outcome Measures

Outcome Measure
Time Frame
Refractive Error
Time Frame: Every 10th visit
Every 10th visit

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

June 1, 2007

Primary Completion (Actual)

December 1, 2009

Study Completion (Actual)

December 1, 2009

Study Registration Dates

First Submitted

May 3, 2007

First Submitted That Met QC Criteria

May 3, 2007

First Posted (Estimate)

May 4, 2007

Study Record Updates

Last Update Posted (Actual)

September 25, 2018

Last Update Submitted That Met QC Criteria

August 28, 2018

Last Verified

August 1, 2018

More Information

Terms related to this study

Additional Relevant MeSH Terms

Other Study ID Numbers

  • 2006H0045

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Myopia

Clinical Trials on NeuroVision's NVC treatment for Low Myopia

3
Subscribe