Drug Eluting Stents In The Critically Ischemic Lower Leg 2 (DESTINY 2)

March 6, 2015 updated by: Flanders Medical Research Program

a Prospective, Multicenter, Controlled Trial Evaluating the Implant of a Drug Eluting Stent (XIENCE PRIME, Abbott Vascular) in the Critically Ischemic Lower Leg

The objective of this clinical evaluation is to evaluate the immediate and long term (up to 12 months) outcome of the XIENCE PRIME Everolimus Eluting Coronary Stent System (Abbott Vascular) in a controlled prospective investigation for the treatment of patients with critical limb ischemia due to the presence of lesions between 3cm and 10cm in length at the level of the below the knee arteries. Specifically the trial aims to illicit angiographic and ultrasound patency, clinical improvement, and adverse events associated with the use of this stent. The trial design is single armed, prospective, controlled trial run over 12 months of follow-up.

Study Overview

Status

Completed

Intervention / Treatment

Detailed Description

The aim of this research is to evaluate the immediate and long term outcome of the XIENCE PRIME EverolimusEluting Coronary Stent System in a prospective investigation for the treatment of patients with critical limb ischemia due to the presence of lesions between 3cm and 10cm in length at the level of the below the knee arteries.

The research question is "Dose the use of an Everolimus coated stent in long tibial artery occlusions, between 3 and 10cm offer superior patency at 12 months compared to a historical cohort of bare metal stents in similar lesions?" Our hypothesis is that the use of everolimus coated stents in tibial artery occlusions between 3 and 10cm will result in lower binary restenosis than was historically found in equivalent but non-drugcoated bare metal stents.

Currently, there is evidence that angioplasty and drug eluting stents can be used as a therapy for patients with critical limb ischemia due to occlusive infrapopliteal disease. The XIENCE PRIME™ Everolimus Eluting Coronary Stent System (XIENCE PRIME EECSS or XIENCE PRIME stent system) is manufactured by Abbott. It is a device/drug combination product consisting of the CobaltChromium MULTILINK VISION 8 Coronary Stent System coated with a formulation containing everolimus, the active ingredient, embedded in a nonerodible polymer. The XIENCE PRIME Everolimus Eluting Coronary Stent is coated with everolimus (active ingredient), embedded in a nonerodible polymer (inactive ingredient). Everolimus is the active pharmaceutical ingredient in the XIENCE PRIME stent. It is a novel semisynthetic macrolide immunosuppressant, synthesized by chemical modification of rapamycin (sirolimus). The everolimus chemical name is 40O(2hydroxyethyl) rapamycin.

The XIENCE PRIME stent contains inactive ingredients including poly n-butyl methacrylate (PBMA), a polymer that adheres to the stent and drug coating, and PVDFHFP, which is comprised of vinylidene fluoride and hexafluoropropylene monomers as the drug matrix layer containing everolimus. PBMA is a homopolymer with a molecular weight (Mw) of 264,000 to 376,000 dalton. PVDFHFP is a nonerodible semicrystalline random copolymer with a molecular weight (Mw) of 254,000 to 293,000 dalton. The drug matrix copolymer is mixed with everolimus (83%/17% w/w polymer/everolimus ratio) and applied to the entire PBMA coated stent surface. The drug load is 100 μg/cm2 for all product sizes. No top-coat layer is used.

Study Type

Interventional

Enrollment (Actual)

60

Phase

  • Phase 2
  • Phase 3

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • New South Wales
      • Randwick, New South Wales, Australia, 2031
        • Prince of Wales Private Hospital
    • Antwerp
      • Bonheiden, Antwerp, Belgium, 2820
        • Imelda Hospital
    • East-Flanders
      • Dendermonde, East-Flanders, Belgium, 9200
        • Department Vascular Surgery, A.Z. Sint-Blasius Hospital
      • Bad Krozingen, Germany, 79189
        • Herz-Zentrum Bad Krozingen
      • Leipzig, Germany, 04289
        • Herzzentrum
      • Münster, Germany, 48145
        • St Fransiskus hospital

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Patient presenting with rest pain or minor tissue loss (Rutherford class 4 or 5)
  • Patient is willing to comply with specified follow-up evaluations at the specified times
  • Patient is >18 years old
  • Patient understands the nature of the procedure and provides written informed consent, prior to enrolment in the study
  • Patient has a projected life-expectancy of at least 12 months
  • Patient is eligible for treatment with the XIENCE PRIME stent (Abbott Vascular)
  • Male, infertile female, or female of child bearing potential practicing an acceptable method of birth control with a negative pregnancy test within 7 days prior to study procedure

Angiographic Inclusion Criteria:

  • De novo lesion or restenotic lesion after PTA in the infrapopliteal arteries, suitable for endovascular therapy
  • Total target lesion length minimally 30mm and maximally 100mm
  • Target vessel diameter visually estimated to be >2.0mm and <3.5mm
  • Guidewire and delivery system successfully traversed lesion

Exclusion Criteria:

  • Patient refusing treatment
  • The reference segment diameter is not suitable for the available stent design
  • Untreated flow-limiting inflow lesions
  • Perioperative unsuccessful ipsilateral percutaneous vascular procedure to treat inflow disease just prior to enrollment
  • Any previous surgery in the target vessel (including prior ipsilateral crural bypass)
  • Aneurysm in the target vessel
  • Non-atherosclerotic disease resulting in occlusion (e.g. embolism, Buerger's disease, vasculitis)
  • Severe medical comorbidities (untreated CAD/CHF, severe COPD, metastatic malignancy, dementia, etc) or other medical condition that would preclude compliance with the study protocol or 1-year life expectancy
  • Major distal amputation (above the transmetatarsal) in the study limb or non-study limb
  • Septicemia or bacteremia
  • Any previously known coagulation disorder, including hypercoagulability
  • Contraindication to anticoagulation or antiplatelet therapy
  • Known allergies to stent or stent components
  • Known allergy to contrast media that cannot be adequately pre-medicated prior to the study procedure
  • Patient with known hypersensitivity to heparin, including those patients who have had a previous incidence of heparin-induced thrombocytopenia (HIT) type II
  • Currently participating in another clinical research trial
  • Angiographic evidence of intra-arterial thrombus or atheroembolism from inflow treatment
  • Target lesion access not performed by transfemoral approach.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: TREATMENT
  • Allocation: NA
  • Interventional Model: SINGLE_GROUP
  • Masking: NONE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
EXPERIMENTAL: Xience Prime stent
Patients with critical limb ischemia due to below the knee arterial lesion between 30 and 100mm in length, treated with the XIENCE PRIME™ Everolimus Eluting Coronary Stent System.
Implantation of one or more Everolimus-eluting XIENCE PRIME™ Everolimus Eluting Coronary Stent Systems.
Other Names:
  • Xience Prime stent

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Primary patency at 12 months
Time Frame: 12 months
Absence of restenosis (≥50% stenosis) or occlusion within the originally treated lesion based on angiography
12 months

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Technical success
Time Frame: procedure
The ability to cross and dilate the lesion to achieve residual angiographic stenosis no greater than 30%
procedure
Hemodynamic primary patency rate at 1, 6, 12-month follow-up
Time Frame: 1, 6, 12-month follow-up
Patients that present without a hemodynamically significant stenosis at the target area on duplex ultrasound (systolic velocity ratio no greater than 2.4) and without prior TLR are defined as being primary patent at the given follow-up.
1, 6, 12-month follow-up
Limb-salvage rate at all follow-up visits
Time Frame: 1, 6, 12-month follow-up
Absence of major amputation. Major amputation is defined as amputation at or above the ankle, as opposed to minor amputation, being an amputation at or below metatarsal level, preserving functionality of the foot).
1, 6, 12-month follow-up
Primary assisted patency rate at 1, 6, 12-month follow-up
Time Frame: 1, 6, 12-month follow-up
Defined as flow through the treated lesion maintained by repeat percutaneous intervention completed prior to complete vessel closure.
1, 6, 12-month follow-up
Secondary patency rate at 1, 6, 12-month follow-up
Time Frame: 1, 6, 12-month follow-up
Defined as flow through the treated lesion maintained by repeat percutaneous intervention after occlusion of the target lesion.
1, 6, 12-month follow-up
Target lesion revascularization (TLR) at all follow-up visits
Time Frame: 1, 6, 12-month follow-up
A repeat intervention to maintain or re-establish patency within the region of the treated arterial vessel plus 5 mm proximal and distal to the treated lesion edge.
1, 6, 12-month follow-up
Clinical success at all follow-up visits
Time Frame: 1, 6, 12-month
An improvement of Rutherford classification at 1 day and 1, 6, 12-month follow-up of one class or more as compared to the pre-procedure Rutherford classification.
1, 6, 12-month
Serious adverse events until follow-up completions
Time Frame: 1,6,12 months and interim visits
Any clinical event that is fatal, life-threatening, or judged to be severe by the investigator; resulted in persistent or significant disability; necessitated surgical or percutaneous intervention; or required prolonged hospitalization.
1,6,12 months and interim visits

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Marc Bosiers, MD, A.Z. Sint-Blasius Hospital

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

July 1, 2011

Primary Completion (ACTUAL)

November 1, 2013

Study Completion (ACTUAL)

November 1, 2014

Study Registration Dates

First Submitted

September 22, 2011

First Submitted That Met QC Criteria

September 27, 2011

First Posted (ESTIMATE)

September 28, 2011

Study Record Updates

Last Update Posted (ESTIMATE)

March 9, 2015

Last Update Submitted That Met QC Criteria

March 6, 2015

Last Verified

March 1, 2015

More Information

Terms related to this study

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Peripheral Arterial Disease

Clinical Trials on stent

3
Subscribe