Mitral Implantation of TRAnscatheter vaLves (MITRAL)

October 3, 2023 updated by: Mayra Guerrero

The Safety and Feasibility of the SAPIEN XTTM Transcatheter Heart Valve With NovaFlex and Ascendra Delivery Systems and SAPIEN 3 With Commander Delivery System in Patients With Symptomatic Severe Calcific Mitral Valve Disease With Severe Mitral Annular Calcification and Patients With Failing Mitral Surgical Rings or Bioprostheses Who Are Not Candidates for Mitral Valve Surgery.

The purpose of this trial is to establish the safety and feasibility of the Edwards SAPIEN XT™and SAPIEN 3™ device and delivery systems in patients with severe symptomatic calcific mitral valve disease with severe mitral annular calcification who are not candidates for standard mitral valve surgery.

Study Overview

Status

Completed

Detailed Description

Design:

A prospective pilot study enrolling extremely high surgical risk patients with symptomatic severe calcific mitral valve disease undergoing implantation of an Edwards Sapien XT or SAPIEN 3 valve in the mitral position.

There are three arms in this study evaluating three separate patient populations described below:

  • Native Mitral Valve with severe Mitral Annular Calcification (MAC): Patients with symptomatic severe disease of a native mitral valve due to severe mitral annular calcification.
  • Valve-in-Ring: Patients with symptomatic failing surgical rings resulting in severe mitral regurgitation or stenosis.
  • Valve-in-Valve: Patients with failing bioprosthetic surgical valves with severe regurgitation or stenosis

The delivery approaches include: standard transeptal, modified transeptal approach with a guidewire externalized through a sheath percutaneously placed in the left ventricle, surgical trasnapical and surgical transatrial delivery approach with or without surgical resection of the anterior mitral valve (MV) leaflet (in the native mitral valve arm).

The MITRAL Trial site investigative team (heart team) consists of dedicated representatives from cardiac surgery, interventional cardiology, echocardiology, neurology, study coordination and other multi-disciplinary team members consistent with a transcatheter aortic valve replacement (TAVR) model.

Endpoints

Most endpoints were defined following the Mitral Valve Academic Research Consortium (MVARC) recommendations with minor modifications.73

The primary safety endpoint is: technical success at exit from the cath lab

• Technical success (at exit from the cath lab) is defined as:

  • Successful vascular and/or TA access, delivery and retrieval of the transcatheter valve delivery system
  • Deployment of a single valve
  • Correct position of transcatheter valve in the mitral annulus
  • Adequate performance of the prosthetic heart valve (mean mitral valve gradient (MVG) <10 mmHg) without residual mitral regurgitation (MR) grade ≥2 (+)
  • No need for additional surgery or re-intervention (includes drainage of pericardial effusion)
  • The patient leaves the cath lab alive

The primary performance endpoint is: absence of MR grade 2 (+) or greater or mean MVG ≥10 mmHg at 30 days and 1 year.

Secondary safety endpoints include: Procedural success and all -cause mortality at 30 days and 1 year.

  • Procedural Success (30 days) in defined as:

    • Device success at 30 days
    • No device/procedure related severe adverse event (SAE's) including: death, stroke, MI or coronary ischemia requiring PCI or CABG, stage 2 or 3 AKI including dialysis, life threatening bleeding, major vascular or access complications (arterial, venous, or TA - any event requiring additional unplanned surgical or transcatheter intervention), pericardial effusion or tamponade requiring drainage, severe hypotension, heart failure or respiratory failure requiring intravenous pressors or invasive or mechanical treatments such as ultrafiltration or hemodynamic assist devices including intra-aortic balloon pump or left ventricular assist device, or prolonged intubation for ≥48 hrs, or any valve-related dysfunction, migration, thrombosis, or other complication requiring surgery or repeat intervention.
  • Device success is defined as:

    • Stroke free survival with original valve in place
    • No need for additional surgery or re-intervention related to the procedure, access or to the replacement valve
    • Proper placement and intended function of the replacement valve, including
    • No migration, fracture, thrombosis, hemolysis or endocarditis
    • No replacement valve stenosis (MV gradient < 10 mmHg)
    • Replacement valve regurgitation < 2 + (including central and paravalvular leak) and without associated hemolysis
    • No increase in AI from baseline (more than 1 grade) and LVOT gradient < 20 mmHg increase from baseline

Additional secondary safety and effectiveness endpoints will be evaluated at two time points: (1) acute, covering events occurring out to 30 days or hospital discharge, whichever is longer; and (2) longer-term, covering events from 31 days to 1 year, and include the following:

Additional Safety Endpoints:

Freedom from

  • all stroke and TIA (MVARC)
  • myocardial infarction
  • major vascular complication (MVARC)
  • life-threatening bleeding (MVARC)
  • mitral valve reoperation or catheter-based intervention for: valve thrombosis, valve displacement, or other valve placed procedure-related complication
  • hemolysis
  • endocarditis
  • moderate or severe central mitral insufficiency ≥ 2 (+), and/or moderate or severe perivalvular leak causing ≥ 2 (+) mitral insufficiency
  • significant mitral stenosis (mean MVG >10 mmHg)
  • new permanent pacemaker insertion
  • new aortic valve dysfunction (difference greater than 1(+) severity compared with baseline)
  • new LVOT gradient ≥ 20 mmHg, or ≥ 20 mmHg increase from baseline LVOT gradient.
  • acute kidney injury (MVARC)
  • new onset atrial fibrillation
  • blood transfusion
  • access site infection
  • need for iatrogenic ASD closure after index procedure

Additional Effectiveness Endpoints:

  1. Rehospitalization at 1 year and Total days alive and out of hospital (from date of index procedure)
  2. Clinical improvement per NYHA Class (from baseline) by at least 1 class.
  3. Clinical improvement per Quality of Life instruments (>10 points from baseline): (KCCQ 12) (Appendix N)
  4. Clinical improvement per 6 Minute Walk Test (> 50 meters from baseline) and 5 meter walk test. (Appendix H)
  5. Mean ICU and total index procedure hospital length of stay

Additional Valve Performance Endpoints:

  1. Freedom from major mitral paravalvular leak
  2. Improvement in hemodynamic function: mean gradient
  3. Freedom from structural valve deterioration
  4. Total mitral regurgitation

Study Type

Interventional

Enrollment (Actual)

91

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Arizona
      • Phoenix, Arizona, United States, 85006
        • Banner University Medical Center
    • California
      • Los Angeles, California, United States, 90048
        • Cedars-Sinai Medical Center
    • District of Columbia
      • Washington, District of Columbia, United States, 20010
        • MedStar Washington Medical Center
    • Georgia
      • Atlanta, Georgia, United States, 30309
        • Piedmont HealtCare
    • Illinois
      • Evanston, Illinois, United States, 60201
        • Evanston Hospital / North Shore University HealthSystem
    • Massachusetts
      • Boston, Massachusetts, United States, 02215
        • Beth Israel Deaconess Medical Center
      • Boston, Massachusetts, United States, 02115
        • Brigham and Women's Hospital
      • Boston, Massachusetts, United States, 02114
        • Massachusetts General Hospital
    • Michigan
      • Detroit, Michigan, United States, 48202
        • Henry Ford Hospital
    • Minnesota
      • Rochester, Minnesota, United States, 55905
        • Mayo Clinic
    • New York
      • New York, New York, United States, 10032
        • Columbia University Medical Center
      • New York, New York, United States, 10029
        • Mount Sinai Hospital
    • Texas
      • Houston, Texas, United States, 77030
        • Memorial Hermann Texas Medical Center
    • Utah
      • Murray, Utah, United States, 48107
        • Intermountain Medical Center
    • Washington
      • Seattle, Washington, United States, 98195
        • University of Washington Medical Center

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

22 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Description

Inclusion Criteria in Native Mitral Valve arm

All Candidates must meet the following criteria:

  1. Patient has severe calcific native mitral valve stenosis with mitral annular calcification with echocardiographically derived mitral valve area (MVA) of ≤1.5 cm2, or severe mitral regurgitation with severe mitral annular calcification and at least moderate mitral valve stenosis. Qualifying echo must be within 60 days of the date of the procedure.
  2. Patient is symptomatic from mitral valve disease, as demonstrated by reported NYHA Functional Class II or greater, or symptoms during stress test.
  3. The patient is at least 22 years old.
  4. The heart team agrees (and verified in the case review process) that valve implantation will likely benefit the patient.
  5. The heart team agrees that medical factors preclude operation, based on a conclusion that the probability of death or serious, irreversible morbidity exceeds the probability of meaningful improvement. Specifically, the STS score is ≥15% or the probability of death or serious, irreversible morbidity is ≥ 50%. The surgeons' consult notes shall specify the medical or anatomic factors leading to that conclusion and include a printout of the calculation of the STS score to additionally identify the risks in the patient (some medical factors and definitions are provided below). At least one of the cardiac surgeon assessors must have physically evaluated the patient. All patients must be approved by the Patient Selection and Procedure Management Steering Committee (at least 2 member votes, one must be a cardiac surgeon).
  6. The study patient has been informed of the nature of the study, agrees to its provisions and has provided written informed consent as approved by the Institutional Review Board (IRB) of the respective clinical site.
  7. The study patient agrees to comply with all required post-procedure follow-up visits including annual visits through 5 years and analysis close date visits, which will be conducted as a phone follow-up.

Inclusion Criteria in Valve-in-Ring arm

All Candidates must meet the following criteria:

  1. Patient has a failing surgical ring in the mitral position with severe mitral regurgitation or stenosis (echocardiographically derived mitral valve area [MVA] of ≤1.5 cm2. Qualifying echo must be within 60 days of the date of the procedure.
  2. Patient is symptomatic from mitral valve disease, as demonstrated by reported NYHA Functional Class II or greater, or symptoms during stress test, or severe hemolytic anemia requiring blood transfusions and no other cause of hemolytic anemia is found after extensive work up.

Inclusion Criteria items #3 to 7 will be the same as in Native MV arm described above

Inclusion Criteria in Valve-in-Valve arm

All Candidates must meet the following criteria:

  1. Patient has a failing surgical bioprosthesis in the mitral position with severe mitral regurgitation or stenosis with echocardiographically derived mitral valve area (MVA) of ≤1.5 cm2. Qualifying echo must be within 60 days of the date of the procedure.
  2. Patient is symptomatic from mitral valve disease, as demonstrated by reported NYHA Functional Class II or greater, or symptoms during stress test.

Inclusion Criteria items #3 to 7 will be the same as in Native MV arm described above

Exclusion Criteria:

Candidates will be excluded from the study if any of the following conditions are present:

  1. Heart Team assessment of operability (the heart team considers the patient is a surgical candidate).
  2. Evidence of an acute myocardial infarction ≤ 1 month (30 days) before the intended treatment [defined as: Q wave MI, or non-Q wave MI with total CK elevation of CK-MB ≥ twice normal in the presence of MB elevation and/or troponin level elevation (WHO definition)].
  3. Mitral annulus is not calcified (only applies to patients included in Native MV arm).
  4. Complex untreated coronary artery disease:

    1. Unprotected left main coronary artery
    2. Syntax score > 32 (in the absence of prior revascularization)
  5. Any therapeutic invasive cardiac procedure resulting in a permanent implant that is performed within 30 days of the index procedure (unless part of planned strategy for treatment of concomitant coronary artery disease). Implantation of a permanent pacemaker is not excluded.
  6. Any patient with a balloon valvuloplasty (BMV) within 30 days of the procedure (unless BMV is a bridge to procedure after a qualifying ECHO).
  7. Patients with planned concomitant surgical or transcatheter ablation for Atrial Fibrillation.
  8. Leukopenia (WBC < 3000 cell/mL), acute anemia (Hgb < 9 g/dL), Thrombocytopenia (Plt < 50,000 cell/mL).
  9. Hypertrophic obstructive cardiomyopathy (HOCM).
  10. Hemodynamic or respiratory instability requiring inotropic support, mechanical ventilation or mechanical heart assistance within 30 days of screening evaluation.
  11. Need for emergency surgery for any reason.
  12. Severe ventricular dysfunction with LVEF < 20%.
  13. Echocardiographic evidence of intracardiac mass, thrombus or vegetation.
  14. Active upper GI bleeding within 3 months (90 days) prior to procedure.
  15. A known contraindication or hypersensitivity to all anticoagulation regimens, or inability to be anticoagulated for the study procedure.
  16. For patients enrolled in the Native MV arm: Native mitral annulus size < 275 mm2 or > 740 mm2 as measured by CT scan.

    For patients in Valve-in-Ring arm: surgical ring with a true mean internal diameter ≤18 mm or ≥ 29 mm or an area < 275 mm2 or > 740 mm2 as measured by CT scan. Caution recommended in:

    • Incomplete bands due to risk of paravalvular leak and risk of LVOT obstruction. Careful measurements by CT and CT-guided procedural planning is recommended.
    • Non-circular rigid or semi-flexible rings (e.g., D-shaped, saddle shaped, etc) due to risk of para-valvular leak and/or out of round or incomplete valve expansion.

    For patients in Valve-in-Valve arm: surgical bioprosthesis with a true internal diameter ≤18 mm or ≥ 29 mm

  17. Clinically (by neurologist) or neuroimaging confirmed stroke or transient ischemic attack (TIA) within 6 months (180 days) of the procedure.
  18. Estimated life expectancy < 24 months (730 days) due to carcinomas, chronic liver disease, chronic renal disease or chronic end stage pulmonary disease.
  19. Expectation that patient will not improve despite treatment of mitral stenosis
  20. Active bacterial endocarditis within 6 months (180 days) of procedure.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Non-Randomized
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Native mitral valve with severe MAC
Patients with symptomatic severe calcific native mitral valve disease with severe mitral annular calcification who have extremely high surgical risk for standard surgical mitral valve replacement, will undergo transcatheter mitral valve replacement.
Implantation of a balloon expandable Edwards SAPIEN XT or SAPIEN 3 transcatheter heart valve in the mitral position.
Experimental: Valve-in-Ring
Patients with symptomatic failing surgical rings resulting in severe mitral regurgitation or stenosis will undergo transcatheter mitral valve replacement (valve-in-ring).
Implantation of a balloon expandable Edwards SAPIEN XT or SAPIEN 3 transcatheter heart valve in the mitral position.
Experimental: Valve-in-Valve
Patients with symptomatic failing surgical bioprostheses resulting in severe mitral regurgitation or stenosis will undergo transcatheter mitral valve replacement (Valve-in-valve).
Implantation of a balloon expandable Edwards SAPIEN XT or SAPIEN 3 transcatheter heart valve in the mitral position.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Technical Success at Exit From the Cath Lab.
Time Frame: 30 days

Number of subject to achieve technical success (at exit from cath lab) is defined as:

  • Successful vascular delivery and retrieval of transcatheter valve delivery system
  • Deployment of single valve
  • Correct position of transcatheter valve
  • Adequate performance of prosthesis (MVA > 1.5 cm2) without residual MR grade ≥2 (+)
  • No need for additional surgery or re-intervention
  • Patient leaves cath lab alive
30 days
Absence of MR Grade 2 (+) or Greater
Time Frame: 30 days and 1 year
Number of subjects to have absence of MR grade 2 (+) or greater assessed with echocardiography. MR severity grading system ranging from Grade 1=mild; Grade 4=severe.
30 days and 1 year
Mitral Valve Gradient (MVG)
Time Frame: 30 days and 1 year
MVG assessed by echocardiography measured in mmHg
30 days and 1 year

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Procedural Success
Time Frame: 30 days
Number of subject to have procedural success as defined as no device/procedure related SAE's including: death, stroke, MI or coronary ischemia requiring PCI or CABG, stage 2 or 3 AKI including dialysis, life threatening bleeding, major vascular or access complications (arterial, venous, or TA - any event requiring additional unplanned surgical or transcatheter intervention), pericardial effusion or tamponade requiring drainage, severe hypotension, heart failure or respiratory failure requiring intravenous pressors or invasive or mechanical treatments such as ultrafiltration or hemodynamic assist devices including intra-aortic balloon pump or left ventricular assist device, or prolonged intubation for ≥48 hrs, or any valve-related dysfunction, migration, thrombosis, or other complication requiring surgery or repeat intervention.
30 days

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Collaborators

Investigators

  • Principal Investigator: Mayra E. Guerrero, MD, Mayo Clinic

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

February 25, 2015

Primary Completion (Actual)

December 1, 2018

Study Completion (Actual)

December 1, 2018

Study Registration Dates

First Submitted

February 18, 2015

First Submitted That Met QC Criteria

February 24, 2015

First Posted (Estimated)

February 25, 2015

Study Record Updates

Last Update Posted (Actual)

October 10, 2023

Last Update Submitted That Met QC Criteria

October 3, 2023

Last Verified

October 1, 2023

More Information

Terms related to this study

Other Study ID Numbers

  • 18-006601

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.